What is hysteresis loss?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

What is Hysteresis Loss?

Hysteresis loss refers to the energy dissipation that occurs in ferromagnetic materials (such as iron cores) due to the hysteresis effect during the magnetization process. When the external magnetic field changes, the magnetization of the ferromagnetic material does not immediately follow the change in the magnetic field; instead, there is a lag. Specifically, when the magnetic field strength returns to zero, the magnetization does not completely return to zero but requires a reverse magnetic field to eliminate the residual magnetization. This lag results in energy being dissipated as heat, which is known as hysteresis loss.

The hysteresis loop is a graphical representation of this phenomenon, showing the relationship between magnetic field strength (H) and magnetic flux density (B). The area enclosed by the hysteresis loop represents the energy loss per unit volume of the material for each complete cycle of magnetization.

Role of Hysteresis Loss in Magnetic Circuits

Energy Loss:

In transformers, motors, and other electromagnetic devices, the core is typically made of ferromagnetic material. As these devices operate, the magnetic field within the core frequently changes direction and strength. Each change in the magnetic field leads to hysteresis losses, resulting in energy being dissipated as heat.

This energy loss reduces the overall efficiency of the device because some of the input energy is wasted in heating the core rather than being used for the intended work.

Temperature Rise:

The heat generated by hysteresis losses can cause the core temperature to rise. If the temperature becomes too high, it may damage insulation materials, shorten the lifespan of the equipment, or even cause failure.

Therefore, when designing and selecting ferromagnetic materials, it is crucial to consider their hysteresis characteristics to minimize unnecessary heat generation.

Impact on Device Performance:

High hysteresis losses can reduce the efficiency of the device, especially in high-frequency applications where these losses are particularly significant. To improve efficiency, low coercivity and low hysteresis loss materials such as silicon steel or amorphous alloys are often chosen.

In some cases, magnetic circuit design can be optimized to reduce the frequency of magnetic flux density changes, thereby minimizing hysteresis losses.

Calculation of Hysteresis Loss:

Hysteresis loss can be estimated using the Steinmetz equation:

8459458ab07ca158008cf95a6b1daef8.jpeg

where,Wh is the hysteresis loss per unit volume (watts per cubic meter);

kh is a constant related to the material;

f is the frequency of magnetic field changes (hertz);

Bm is the maximum magnetic flux density (tesla);

n is an empirical exponent, typically ranging between 1.6 and 2.0.

Summary

Hysteresis loss is the energy dissipation caused by the hysteresis effect in ferromagnetic materials, primarily manifesting as heat. In magnetic circuits, it affects the efficiency and temperature rise of devices, so careful consideration must be given to material selection and design. By choosing appropriate materials and optimizing designs, hysteresis losses can be effectively reduced, improving the overall performance and lifespan of the equipment.

Give a tip and encourage the author!
Recommended
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit