• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Dielectric combined voltage tests (BIAS test) on circuit breakers
Dielectric Bias Testing of High-Voltage Circuit BreakersDielectric bias testing is a critical procedure used to evaluate the insulation performance of high-voltage circuit breakers (CBs) under conditions that simulate real-world voltage stresses. In this test, the circuit breaker is subjected to two separate voltages simultaneously: a power frequency (PF) voltage and either a switching (SW) impulse or a lightning impulse (LI). This combination of voltages mimics the actual voltage conditions tha
12/25/2024
Consult
Tip
Consult
Tip
High Voltage Circuit Breaker
Arc Voltage in Gas Circuit BreakersIn gas circuit breakers, the arc voltage is a critical parameter that influences the interruption process and the overall performance of the breaker. The arc voltage can range from a few hundred volts to several kilovolts, depending on various factors. Below is a detailed explanation of the key factors that affect the arc voltage:1.Arc Length Principle: The voltage drop across the arc is directly proportional to the length of the arc. As the arc length increase
12/24/2024
Consult
Tip
Consult
Tip
High voltage switchgear insulators creepage distance extending ways in substations
Site Condition Severity Assessment and Insulator/Bushing Upgrade StrategyStep-by-Step Approach: Measure or Estimate Site Condition Severity: Environmental Factors: Assess the severity of environmental conditions such as pollution, humidity, temperature fluctuations, and salt spray (for coastal areas). Operational Data: Collect data on historical insulator performance, including flashover incidents, arcing, and contamination levels. Field Inspections: Conduct visual inspections to identify si
12/23/2024
Consult
Tip
Consult
Tip
Transient Electromagnetic Emissions(TEE) measurement methods in switchgears
TEE Detection Methods During CB Switching OperationsDuring circuit breaker (CB) switching operations, transient earth voltages (TEEs) are generated by electric discharges within each interrupter. These TEEs, caused by disruptive discharges such as pre-strikes, re-ignitions, and restrikes, exhibit high amplitude and a broadband frequency range. To detect and analyze these TEEs, three primary methods have been developed: TEE Detection with UHF Antennas Description: This method employs four passive
12/21/2024
Consult
Tip
Consult
Tip
Vibration signal application in switchgear
Vibration Signal Analysis for Circuit Breaker (CB) Health MonitoringIntroductionDuring the opening and closing processes of a circuit breaker (CB), a vibration signal is generated. This signal contains valuable information about the health status of the equipment, including the moment of arc contact opening, which can indicate wear and tear, mechanical issues, or other potential problems. One critical aspect of CB health monitoring is the measurement of switchgear contacts ablation, which refers
12/21/2024
Consult
Tip
Consult
Tip
Torsion bar spring operating mechanisms for circuit breaker
Enhanced Interrupting Capabilities and Mechanical Reliability in Gas-Insulated Circuit Breakers (GCBs)Mitsubishi Electric has developed a highly advanced torsion bar spring operating mechanism for Gas-Insulated Circuit Breakers (GCBs), which has enabled the development of higher interrupting capabilities, reaching up to 550/420 kV. This innovative mechanism offers several key benefits, including increased mechanical reliability and reduced maintenance requirements.Key Features of the Torsion Bar
12/19/2024
Consult
Tip
Consult
Tip
What are the similarities and differences between DC MCCB and DC MCB?
Similarities Between DC Molded Case Circuit Breakers (MCCB) and DC Miniature Circuit Breakers (MCB) Basic Function: Both provide overload and short-circuit protection, ensuring that the circuit is automatically interrupted when the current exceeds a set value to prevent equipment damage or safety hazards such as fires. Operating Principle: They both use thermal-magnetic or electronic trip mechanisms to detect abnormal currents and trigger disconnection based on preset conditions. Application Sco
12/18/2024
Consult
Tip
Consult
Tip
Disadvantage of overvoltage limitation methods in shunt reactor switching by circuit breakers according to IEEE
Overvoltage Protection Measures in SwitchgearIn high-voltage circuit breakers (CB), several protection methods are commonly used to address transient recovery voltage (TRV) and other overvoltage phenomena. Below are some typical protection methods along with their advantages and disadvantages:1.Opening Resistor Advantages: Provides additional damping during the opening of the circuit breaker, which helps in suppressing overvoltages. Disadvantages: Increased Mechanical Complexity: The opening r
12/18/2024
Consult
Tip
Consult
Tip
Short Line Fault interruption(SLF) principle in grid by circuit breakers
High-Frequency Transient Recovery Voltage (TRV) in Transmission LinesWhen a fault occurs on a transmission line at a distance ranging from 100 meters to several kilometers, a circuit breaker (CB) is required to clear the short-line fault (SLF). The process of clearing the fault by the circuit breaker can lead to the generation of a Transient Recovery Voltage (TRV) with a steep rate of rise, often resembling a sawtooth waveform. This phenomenon is caused by high-frequency oscillations generated b
12/17/2024
Consult
Tip
Consult
Tip
What are the 3-phase MCB types?
Types of Three-Phase MCBsThree-phase miniature circuit breakers (MCBs) can be classified into various types based on their pole configuration, tripping characteristics, rated current, and specific applications. Below is a detailed overview of the common types of three-phase MCBs:1. Classification by Pole Configuration3P (Three-Pole) MCB: Application: Used in pure three-phase circuits without a neutral line (N). Suitable for applications like three-phase motors and industrial equipment where a ne
12/16/2024
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.