• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


RPS 15/27kV SF6 Load break switch(LBS) technology specification
Technical Data · ROCKWILL

RPS 15/27kV SF6 Load break switch(LBS) technology specification

15‑27 kV outdoor three‑phase load break switch, IP65 outdoor enclosure, M2 mechanical / E3 electrical endurance, multi‑mode local‑remote operation, rich ANSI‑compliant protection functions, multi‑protocol SCADA connectivity for overhead distribution netwo

Updated2026.09
LanguageEnglish
FilePDF · 395.6 KB
15/27kV SF6 Load break switch(LBS)technology specification

Document description

This is OEM technical specification for outdoor overhead‑line load break switch, complying with prevailing IEC high‑voltage switchgear series standards.

This document defines comprehensive switch‑body performance indexes, controller protection‑measurement functions, EMC requirements, supported communication protocols and network access modes, manual/remote operation logic, gas‑monitoring requirements, counter function, and scope of supporting mounting accessories.

It specifies performance classes, protection element mapping and backup‑battery operating conditions, and supports customized manufacture for overhead‑network projects. Contact us for full‑set compliance‑certificates and drawing packages.

Related Products

Frequently asked questions

Multiple mainstream industrial communication protocols are supported; wired Ethernet and wireless cellular network access are both available to satisfy tele‑control, tele‑metering, event‑recording requirements for distribution automation projects. Please contact us for communication‑solution‑checklist.

The controller implements a complete set of ANSI‑standard protection elements, covering over‑current, residual earth‑fault, overload, under‑/over‑voltage, frequency‑related protection as well as supervision and lock‑out logics for field‑device monitoring. Please contact us for protection‑setting‑guidance.

It supports three operation ways: hot‑stick manual local operation, local push‑button control, and remote operation via communication links from the distribution control center. Operation restrictions apply under loss of auxiliary power. Please contact us for operation‑logic‑reference.

WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register