RHD-245 SF6 Gas Dead tank Circuit Breaker FLYER
RHD‑245 SF6 dead‑tank circuit breaker, 245kV, rated current 3150‑5000A, short‑circuit breaking current 40‑63kA, self‑blast arc‑extinguishing, three‑phase SF6 gas insulated high‑voltage circuit‑breaker.
RHD‑245 SF6 dead‑tank circuit breaker, 245kV, rated current 3150‑5000A, short‑circuit breaking current 40‑63kA, self‑blast arc‑extinguishing, three‑phase SF6 gas insulated high‑voltage circuit‑breaker.
This product flyer acts as technical reference for high‑voltage SF6 dead‑tank circuit‑breaker, supporting tender drafting, transmission substation project evaluation and pre‑sales technical review.
The product complies with IEC 62271‑100 and GB/T 1984 standards. This datasheet covers full set of technical indicators including lightning impulse and one‑minute power‑frequency withstand voltage, specified creepage distance range, partial discharge requirement, SF₆ alarm‑block pressure threshold, gas moisture limit, annual gas leakage rate, mechanical endurance and special reclosing operation sequence O‑0.3s‑CO‑180s‑CO.
It features three‑phase post‑porcelain‑insulator structure and pointer‑type density relays for continuous SF6 gas pressure and density supervision. The document also defines power supply parameters for heater, energy‑store motor and control circuit, as well as first‑open‑pole factor, cable‑line charging breaking capacity and time‑related switching performance parameters.
Custom‑made solutions including design, assembly and factory test are available for EPC projects. Please contact us for complete type‑test reports and full operation‑maintenance manuals.
230-252kV Dead-Tank SF6 Breaker: 9-degree seismic, ≤1% leakage. High-reliability for 220kV+ grids & new energy bases.
Outdoor dead tank SF6 circuit breaker direct supply for 362kV systems, delivering reliable high-voltage protection for transmission networks.
Three-phase AC dead tank SF6 circuit breaker source manufacturer for 72.5kV systems, delivering reliable high-voltage protection and switching solutions.
Thời gian đóng cắt phản ánh tốc độ phản hồi của cơ cấu, yếu tố ảnh hưởng trực tiếp đến tốc độ cắt sự cố và điều kiện phục hồi quá độ của lưới điện. Vui lòng liên hệ với chúng tôi để nhận tài liệu phân tích trình tự thời gian.
Tín hiệu kích hoạt khi mật độ khí SF6 giảm xuống ngưỡng đặt trước. Cảnh báo nhắc nhở người vận hành bổ sung khí; khóa liên động cấm thao tác đóng cắt nhằm ngăn ngừa sự cố cách điện bên trong. Vui lòng liên hệ với chúng tôi để tham khảo thông số cài đặt.
Bố cục tích hợp ba pha tối ưu hóa diện tích chiếm dụng tổng thể, giảm diện tích chiếm dụng nền móng và đơn giản hóa công tác đi cáp tại hiện trường so với giải pháp riêng lẻ một pha. Vui lòng liên hệ với chúng tôi để biết chi tiết so sánh bố cục.