Plug-and-Play CT Module: A Game-Changing Solution for Fast GIS Current Transformer Maintenance

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

Plug-and-Play CT Module Rapid Replacement Solution: Revolutionizing Efficient Maintenance for GIS Current Transformers

In high-reliability power scenarios like nuclear power plants and data centers, every minute of equipment downtime can mean significant economic losses or safety hazards. When traditional GIS current transformers (CTs) fail, the entire gas compartment must be depressurized and isolated for replacement, a process taking several days. This solution utilizes an innovative plug-and-play CT module design to achieve a ​90% reduction in maintenance time, addressing the core operational challenge in GIS system maintenance.

Key Technical Highlights

  1. Ultra-Fast Installation/Removal - Quick-Release Metal-Sealed Bellows Interface
    • Modular CT gas chamber interface enables physical isolation; removal does not require depressurization of the main GIS gas compartment.
    • Metal-sealed bellows structure ensures permanent elasticity and insulation performance within a range of -40°C to 105°C.
    • Dedicated hydraulic separation tools enable damage-free separation of gas-tight surfaces; full removal/installation process takes ​<120 minutes​ (vs. ~72h for traditional solutions).
  2. Plug-and-Play Operation - Calibration-Free EEPROM Technology
    • Industrial-grade AT24C512 chips embedded in CT secondary windings pre-store calibration parameters (linearity compensation ±0.1%, phase compensation angle <2 arcminutes).
    • Automatic matching with GIS measurement/control units upon connection, eliminating traditional current ratio/phase error verification steps.
    • Supports ​30,000 read/write cycles​ with a ​>25-year​ data retention period.
  3. Field Verification - Portable Calibration System
    • Handheld injection tester outputs ​0.5~5000A adjustable current (Class 0.05 accuracy), meeting IEC 61869-2 testing requirements.
    • Automatic comparison of operational parameters against EEPROM reference values; accuracy verification completed in ​<30 minutes.
    • Bluetooth transmission of reports to operation & maintenance (O&M) platforms for generation of ​digital maintenance records​ (ISO 55001 compliant).

Application Scenario Value

Scenario

Traditional Solution Pain Point

Value of This Solution

Nuclear Power Plant

Shutdown/refueling outage losses ​> $2 million/day

Saves ​> $1.8 million per maintenance event

Data Center

Power outage causing IDC service level agreement (SLA) breaches

Enables ​Tier IV continuous power supply

Urban Power Grid

Load transfer increases systemic risk

Avoids chain-fault risks​ in 500kV power grids

Core Advantages

  • 90% Faster Fault Recovery: Reduced from an average of ​72 hours to under 7 hours​ (including testing).
  • Zero Planned Outages: GIS main body remains ​energized during operation, eliminating load loss.
  • 60% Lower O&M Costs: Reduced need for lifting equipment/specialized personnel.
  • Traceable Maintenance: Generates ​digital calibration reports​ for every maintenance action (ISO 55001 compliant).

Case Study: At a nuclear power base implementing this solution, the GIS ​average annual fault downtime dropped from 87 hours to 0.8 hours.

07/10/2025
Recommended
Application of New DC Circuit Breakers in Short-Circuit Fault Protection
I. Introduction​With the rapid advancement of modern information technology, intelligence has become a major trend in the development of industrial equipment. In the field of high-voltage switching, intelligent circuit breakers—as critical control components in power systems—form the foundation for automation and intelligence in power systems. This study focuses on an intelligent DC circuit breaker based on single-chip microcomputer (SCM) technology, emphasizing its practical applica
Application Solutions of DC Circuit Breakers in the New Energy Sector
I. Overview​With the rapid development of new energy power generation and electric vehicle (EV) charging facilities, DC systems have imposed higher requirements for safety protection equipment. Traditional AC circuit breakers cannot effectively interrupt DC fault currents, creating an urgent need for specialized DC circuit breaker solutions. This solution provides professional protection configurations for two major application scenarios: photovoltaic (PV) power generation systems and EV chargin
Low-Cost, Low-Loss DC Arc-Free Circuit Breaker Solution for Rail Transit
I. Solution Overview​This solution addresses the protection needs of DC systems (particularly rail transit traction power supply) against short-circuit faults by proposing a DC circuit breaker solution based on optimized mechanical breaker structure. It achieves arc-free interruption through capacitor voltage control, combining low on-state loss and high reliability, making it suitable for frequent operation scenarios.​II. Core Principle​Utilizes a fast mechanical switch topology combined with p
PEBS Circuit Breaker DC Safety Solution
Solution Overview​In modern renewable energy power systems, such as photovoltaic (PV) power generation and energy storage systems, fault protection on the DC side is a core element for ensuring safe, stable, and efficient operation. The Projoy PEBS series DC miniature circuit breakers are specifically designed for such applications, providing a comprehensive and efficient solution integrating arc control, overload protection, and short-circuit protection. This solution aims to deliver the highes
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.