Technical Solution: RW Series Vacuum Pressure Impregnation (VPI) Dry-Type Transformers

Rockwill
17yrs 700++ staff 108000m²+m² US$0+ China

Technical Solution: RW Series Vacuum Pressure Impregnation (VPI) Dry-Type Transformers

I. Core Technological Innovations

  1. Defect-Free Insulation System
    • Utilizes Vacuum Pressure Impregnation (VPI) process to cast high-density epoxy resin, achieving void-free solidified insulation.
    • Partial discharge levels stably controlled at ​<10 pC​ (IEC 60076-11 standard).
    • Insulation thermal class reaches ​Class H (180°C), with insulation performance degradation rate ​≤5%​ throughout the lifespan.
  2. Robust Environmental Adaptability Structure
    • Integrated casting and sealing technology, achieving ​IP54 protection​ (resists persistent dust ingress and water splashing from all directions).
    • Flame-retardant grade F1​ (per GB/T 2207 standard testing, no sustained combustion under 900°C open flame).
    • Wide operating temperature range: ​-25°C to +40°C​ (no derating required in areas at ​≤1000m altitude).
  3. Energy Efficiency Optimization Design
    • ​≥15% reduction**​ in no-load losses for SCBH15/SCB14 series compared to GB 20052 energy efficiency standard.
    • Measured data (1000kVA): No-load loss ​≤0.40kW, Load loss ​≤7.8kW.
    • Dynamic load loss optimization technology, achieving efficiency ​≥98.5%​ within the 35%~100% load range.
  4. Intelligent Maintenance System
    • Embedded ​PT100 platinum resistors in windings​ (IEC 60751 Class A accuracy, temperature measurement error ​±1°C).
    • Supports ​Modbus RTU/TCP protocols. Enables via IoT gateway:
      • Real-time winding hot-spot temperature monitoring.
      • Three-phase unbalance analysis.
      • Dynamic load-rate energy efficiency assessment.

II. Scenario-Based Application Advantages

Application Scenario

Core Problem Solved

Technical Implementation Path

General Industry

Metal dust erosion; Frequent equipment starts/stops

IP54 housing seal + VPI pollution-resistant structure

Commercial Complexes

Stringent fire codes; Compact space

F1 flame-retardant grade + Compact design (28% footprint reduction)

Data Centers

Harmonic pollution (THDi ​≤8%); Require 7×24 stable power

Anti-harmonic magnetic circuit design + ​±2°C​ temperature control accuracy

III. Life Cycle Cost Optimization

Parameter

Oil-Immersed Transformer

This Solution

Benefit Comparison

Maintenance Cycle

Every 2 years

Maintenance-free

Saves ​¥40k/year​ in maintenance

Failure Rate

0.8 per 1000 units/year

0.2 per 1000 units/year

60% reduction​ in downtime losses

Residual Value (20 yrs)

30%

55%

25% increase​ in asset value

Total Cost of Ownership

Benchmark

30% lower

 

(Validated by TCO Model)

     

IV. Engineering Validation Data

  • Accelerated Aging Test:​ Continuous operation for ​5000 hours at 40°C/85% RH; Insulation resistance maintained ​≥1000 MΩ.
  • Seismic Performance:​ Passed ​Class II seismic test​ per GB/T 13540 standard (horizontal acceleration ​0.3g).
  • Noise Control:​ ​≤55 dB(A)​ noise level during operation at ​1000kVA load​ (measured at ​1m distance).
07/04/2025
Recommended
Application of New DC Circuit Breakers in Short-Circuit Fault Protection
I. Introduction​With the rapid advancement of modern information technology, intelligence has become a major trend in the development of industrial equipment. In the field of high-voltage switching, intelligent circuit breakers—as critical control components in power systems—form the foundation for automation and intelligence in power systems. This study focuses on an intelligent DC circuit breaker based on single-chip microcomputer (SCM) technology, emphasizing its practical applica
Application Solutions of DC Circuit Breakers in the New Energy Sector
I. Overview​With the rapid development of new energy power generation and electric vehicle (EV) charging facilities, DC systems have imposed higher requirements for safety protection equipment. Traditional AC circuit breakers cannot effectively interrupt DC fault currents, creating an urgent need for specialized DC circuit breaker solutions. This solution provides professional protection configurations for two major application scenarios: photovoltaic (PV) power generation systems and EV chargin
Low-Cost, Low-Loss DC Arc-Free Circuit Breaker Solution for Rail Transit
I. Solution Overview​This solution addresses the protection needs of DC systems (particularly rail transit traction power supply) against short-circuit faults by proposing a DC circuit breaker solution based on optimized mechanical breaker structure. It achieves arc-free interruption through capacitor voltage control, combining low on-state loss and high reliability, making it suitable for frequent operation scenarios.​II. Core Principle​Utilizes a fast mechanical switch topology combined with p
PEBS Circuit Breaker DC Safety Solution
Solution Overview​In modern renewable energy power systems, such as photovoltaic (PV) power generation and energy storage systems, fault protection on the DC side is a core element for ensuring safe, stable, and efficient operation. The Projoy PEBS series DC miniature circuit breakers are specifically designed for such applications, providing a comprehensive and efficient solution integrating arc control, overload protection, and short-circuit protection. This solution aims to deliver the highes
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.