ROCKWILL H59 Grounding Transformer Solution: Zig-Zag Winding & Smart Monitoring for Neutral Grounding Systems

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

ROCKWILL H59 Grounding Transformer Solution: Zig-Zag Winding & Smart Monitoring for Neutral Grounding Systems​

Application Scenarios:
Neutral point grounding in ungrounded or resonant grounded systems, limiting single-phase ground fault current, suppressing system overvoltage.

 

​I. Core Design Solutions​

  1. Customized Grounding Transformer
    • Built on the ​H59 oil-immersed transformer platform, with high-voltage side using ​Zig-Zag windings​ or ​Yn-d connection​ to provide stable neutral grounding impedance.
    • Complies with ​IEC 60076​ and ​NF C52-112 standards, with insulation strength designed to withstand ground fault current surges.
  2. Key Parameters Configuration

Parameter

Value/Specification

Rated Voltage

System voltage adaptation (6kV/10kV/20kV/33kV)

Short-Time Overload

Withstands 10–20× rated current for 10 seconds

Zero-Sequence Impedance

Customized per system capacitive current (Typical: 40Ω–100Ω)

Connection Method

Znyn11 or YNd11

  1. Grounding Method Selection
    • Resistance Grounding: Secondary side connected to ​stainless steel grid resistor cabinets, limiting fault current to a safe range (Optional: 200A–2000A).
    • Arc Suppression Coil Grounding: Paired with automatic tuning arc suppression coils to extinguish fault-point arcs.

 

​II. Technical Advantages​

  1. Reliable Structure & Protection
    • Fully sealed oil tank: ​IP23 protection rating, suitable for outdoor installation (–25℃ to +50℃).
    • Epoxy resin bushings: High-voltage side uses ​33kV-grade T-type cable terminations (EPDM material)​, ensuring insulation reliability in humid environments.
  2. Intelligent Monitoring System
    • Integrated ​DGPT2/DMCR protection relays​ for real-time monitoring of:
      ✓ Neutral point current/voltage
      ✓ Oil temperature (55℃ max. temperature rise)
      ✓ Oil level & pressure transients
      ✓ Fault gases (H₂, CH₄) content.
  3. High Efficiency & Energy Saving
    • Copper windings + ONAN cooling: No-load loss ≤0.2% of rated capacity (e.g., 1300W for 630kVA).
    • Efficiency >98.5%​​ (at full load, cosφ=1), meeting green grid standards.

 

​III. Engineering Adaptation Services​

  1. Customized Configuration
    • Bushings creepage distance customized for altitude (>1000m requires reinforced insulation) and pollution levels.
    • Optional add-ons:
      • 5-position non-excitation tap changer (±2×2.5%)​
      • Stainless oil valves & anti-vibration roller bases​.

 

​IV. Typical Case Parameters​

Capacity (kVA)

System Voltage (kV)

Zero-Seq. Impedance (Ω)

Resistor Current (A)

Protection Device

300

20

60

400

DGPT2 + Thermostat

500

33

85

800

DMCR + Gas Relay

 

​V. Service Commitment​

  • 10-year warranty: Lifelong maintenance for seals and windings.
  • 48-hour response: Technical support hotline ​​+86 577 27869969.
  • Documentation provided: Grounding calculation reports, type test certificates (including temperature rise & short-circuit tests).

Note: This solution requires user-provided parameters (e.g., system short-circuit capacity, capacitive current) for precision engineering. Rockwill engineers will customize designs accordingly.

06/13/2025
Recommended
Application of New DC Circuit Breakers in Short-Circuit Fault Protection
I. Introduction​With the rapid advancement of modern information technology, intelligence has become a major trend in the development of industrial equipment. In the field of high-voltage switching, intelligent circuit breakers—as critical control components in power systems—form the foundation for automation and intelligence in power systems. This study focuses on an intelligent DC circuit breaker based on single-chip microcomputer (SCM) technology, emphasizing its practical applica
Application Solutions of DC Circuit Breakers in the New Energy Sector
I. Overview​With the rapid development of new energy power generation and electric vehicle (EV) charging facilities, DC systems have imposed higher requirements for safety protection equipment. Traditional AC circuit breakers cannot effectively interrupt DC fault currents, creating an urgent need for specialized DC circuit breaker solutions. This solution provides professional protection configurations for two major application scenarios: photovoltaic (PV) power generation systems and EV chargin
Low-Cost, Low-Loss DC Arc-Free Circuit Breaker Solution for Rail Transit
I. Solution Overview​This solution addresses the protection needs of DC systems (particularly rail transit traction power supply) against short-circuit faults by proposing a DC circuit breaker solution based on optimized mechanical breaker structure. It achieves arc-free interruption through capacitor voltage control, combining low on-state loss and high reliability, making it suitable for frequent operation scenarios.​II. Core Principle​Utilizes a fast mechanical switch topology combined with p
PEBS Circuit Breaker DC Safety Solution
Solution Overview​In modern renewable energy power systems, such as photovoltaic (PV) power generation and energy storage systems, fault protection on the DC side is a core element for ensuring safe, stable, and efficient operation. The Projoy PEBS series DC miniature circuit breakers are specifically designed for such applications, providing a comprehensive and efficient solution integrating arc control, overload protection, and short-circuit protection. This solution aims to deliver the highes
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.