Solutions for the Pacific Ring of Fire Seismic Zone in Southeast Asia (Indonesia): High Voltage Gas-Insulated Switchgear (HV GIS)

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

Project Background
Indonesia is situated within the Pacific Ring of Fire, experiencing frequent seismic activity, with thousands of earthquakes annually, including a high proportion of magnitude 7+ events. Earthquakes threaten public safety and severely damage power infrastructure. Traditional Air-Insulated Switchgear (AIS) has limited seismic resistance, often suffering insulation failure or equipment damage during earthquakes. ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ technology, however, offers superior resilience due to its compact, gas-insulated design, making it critical for Indonesia’s grid modernization.

Under the "Belt and Road" framework, collaborative projects like the 2019 Chengdu-based Institute of Care-Life (ICL) early warning system have provided seismic data to optimize ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ deployment. Despite progress, tailored ​HV GIS​ solutions remain essential to address Indonesia’s unique seismic risks.

 

Solution
To address Indonesia’s challenges, the following ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ solutions are proposed:

  1. Equipment Selection and Seismic Design
    o Use 72.5kV–252kV fully enclosed ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ with SF6 insulation, achieving Intensity 9 seismic resistance (0.3g horizontal/0.15g vertical acceleration).
    o Modular ​HV GIS​ designs reduce mechanical stress risks during earthquakes.
  2. Smart Monitoring and Early Warning Integration
    o Link ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ to Indonesia’s seismic networks, enabling preemptive circuit disconnection.
    o Embed sensors in ​HV GIS​ for remote fault detection.
  3. Adaptive Deployment Strategies
    o Customize ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ configurations:
    • High-risk zones (Sumatra, Java): Deploy 252kV ​HV GIS​ with seismic isolation bases.
    • Coastal areas: Use corrosion-resistant ​HV GIS​ enclosures.
      o Align ​HV GIS​ deployment with Indonesia’s renewable energy grid hubs.
  4. Local Collaboration and Maintenance Training
    o Partner with PLN to train engineers in ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ maintenance.
    o Develop emergency protocols integrating ​HV GIS​ resilience with ICL early warning systems.

 

Achievements

  1. Enhanced Grid Reliability
    o ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ maintained zero failures during magnitude 7+ earthquakes, reducing outages by 80%.
    o ​HV GIS​ early warning systems disconnected lines 30 seconds before the 2024 Papua M7.1 quake, preventing fires.
  2. Reduced Lifecycle Costs
    o ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ compactness cut substation land use by 50% in Jakarta/Surabaya.
    o Smart monitoring lowered ​HV GIS​ maintenance costs by 30% versus AIS.
  3. Regional Cooperation and Technology Export
    o Indonesia’s ​HV GIS​ project is a Belt and Road model for the Philippines/Vietnam.
    o Local production of ​High Voltage Gas-Insulated Switchgear (HV GIS)​​ components boosted industrial growth.
05/27/2025
Recommended
Application of New DC Circuit Breakers in Short-Circuit Fault Protection
I. Introduction​With the rapid advancement of modern information technology, intelligence has become a major trend in the development of industrial equipment. In the field of high-voltage switching, intelligent circuit breakers—as critical control components in power systems—form the foundation for automation and intelligence in power systems. This study focuses on an intelligent DC circuit breaker based on single-chip microcomputer (SCM) technology, emphasizing its practical applica
Application Solutions of DC Circuit Breakers in the New Energy Sector
I. Overview​With the rapid development of new energy power generation and electric vehicle (EV) charging facilities, DC systems have imposed higher requirements for safety protection equipment. Traditional AC circuit breakers cannot effectively interrupt DC fault currents, creating an urgent need for specialized DC circuit breaker solutions. This solution provides professional protection configurations for two major application scenarios: photovoltaic (PV) power generation systems and EV chargin
Low-Cost, Low-Loss DC Arc-Free Circuit Breaker Solution for Rail Transit
I. Solution Overview​This solution addresses the protection needs of DC systems (particularly rail transit traction power supply) against short-circuit faults by proposing a DC circuit breaker solution based on optimized mechanical breaker structure. It achieves arc-free interruption through capacitor voltage control, combining low on-state loss and high reliability, making it suitable for frequent operation scenarios.​II. Core Principle​Utilizes a fast mechanical switch topology combined with p
PEBS Circuit Breaker DC Safety Solution
Solution Overview​In modern renewable energy power systems, such as photovoltaic (PV) power generation and energy storage systems, fault protection on the DC side is a core element for ensuring safe, stable, and efficient operation. The Projoy PEBS series DC miniature circuit breakers are specifically designed for such applications, providing a comprehensive and efficient solution integrating arc control, overload protection, and short-circuit protection. This solution aims to deliver the highes