| Muhimmiya | Transformer Parts |
| Model NO. | WSLD Series electric cage tap changer WSLD Series electric cage tap changer |
| Rated Voltage | 35kV |
| Raitidu kọ̀ọ̀kan | 800A |
| Na' iya masu yin kawo da yanayi | Neutral voltage regulation |
| Na'ibi na tukarƙi | 5~10 |
| Na'urar da yawan makarantunƙasa | 5~10 |
| Siri | WSLD Series |
Overview
WSLD Series Non-excitative tap-changer belongs to a cage-like structure without oil container, which can be directly installed in the oil tank of the transformer. According the different outline structures, the switch can be divided into vertical, bell and horizontal types.
outline

Switch type |
Rated Voltage kV |
Position of Voltage regulation |
Installation Dimension |
|||
L1 |
L2 |
H1 |
H2 |
|||
WSLⅡDL200 - 400/10 - 6X5 - 10X9 F |
10 |
Central part |
210 |
110 |
540 |
720 |
WSLⅢDL200 - 400/10 - 5X5 - 10X10 F |
10 |
Neutral Point |
210 |
110 |
540 |
720 |
WSLⅡDL630 - 800/10 - 6X5 - 10X;9 F |
10 |
Central part |
230 |
130 |
610 |
790 |
WSLⅢDL630 - 800/10 - 5X5 - 10X0 F |
10 |
Neutral Point |
230 |
130 |
610 |
790 |
WSLⅡDL200 - 400/35 - 6X5 - 10X9 F |
35 |
Central part |
275 |
170 |
710 |
890 |
WSLⅢDL200 - 400/35 - 5X5 - 10X10 F |
35 |
Neutral Point |
275 |
170 |
710 |
890 |
WSLⅡDL630 - 800/35 - 6X5 - 10X9 F |
35 |
Central part |
300 |
195 |
810 |
990 |
WSLⅢDL630 - 800/35 - 5X5 - 10&X10 F |
35 |
Neutral Point |
310 |
200 |
815 |
990 |

Switch type |
Rated Voltage kV |
Position of Voltage regulation |
Installation Dimension |
|||
L1 |
L2 |
H1 |
H2 |
|||
| WSLⅡDL200~400/10 - 11X10~14X13 F | 10 |
Central part |
210 |
110 |
540 |
720 |
| WSLⅢDL200~400/10 - 11X11~14X14 F | 10 |
Neutral Point |
210 |
110 |
540 |
720 |
| WSLⅡDL630~800/10 - 11X10~12X11 F | 10 |
Central part |
230 |
130 |
610 |
790 |
| WSLⅢDL630~800/10 - 11X11~12X12 F | 10 |
Neutral Point |
230 |
130 |
610 |
790 |
| WSLⅡDL200~400/35 - 11X10~14X13 F | 35 |
Central part |
275 |
170 |
710 |
890 |
| WSLⅢDL200~400/35 - 11X11~14X14 F | 35 |
Neutral Point |
275 |
170 |
710 |
890 |
| WSLⅡDL630~800/35 - 11X10~12X11 F | 35 |
Central part |
300 |
195 |
810 |
990 |
| WSLⅢDL630~800/35 - 11X11~12X12 F | 35 |
Neutral Point |
310 |
200 |
815 |
990 |

Switch type |
Rated Voltage kV |
Position of Voltage-regulation |
Installation Dimension |
|||
L1 |
L2 |
H1 |
H2 |
|||
WSⅡJLDL200~630/10 - 4×3~10×9 Y |
10 |
Central part |
150 |
110 |
480 |
716 |
WSⅡJLDL200~630/10 - 5×5~10×10 Y |
10 |
Neutral Point |
150 |
110 |
480 |
716 |
WSⅡJLDL800/10 - 6×5~10×9 Y |
10 |
Central part |
170 |
130 |
550 |
786 |
WSⅡJLDL800/10 - 5×5~10×10 Y |
10 |
Neutral Point |
170 |
130 |
550 |
786 |
WSⅡJLDL200~630/35 - 6×5~10×9 Y |
35 |
Central part |
210 |
170 |
650 |
886 |
WSⅡJLDL200~630/35 - 5×5~10×10 Y |
35 |
Neutral Point |
210 |
170 |
650 |
886 |
WSⅡJLDL800/35 - 6×5~10×9 Y |
35 |
Central part |
240 |
195 |
750 |
986 |
WSⅡJLDL800/35 - 5×5~10×10 Y |
35 |
Neutral Point |
240 |
195 |
750 |
986 |