• WDJB-3000SM Digital-Analog Integrated Relay Protection Tester
  • WDJB-3000SM Digital-Analog Integrated Relay Protection Tester
  • WDJB-3000SM Digital-Analog Integrated Relay Protection Tester
WDJB-3000SM Digital-Analog Integrated Relay Protection Tester
$36000.00
Model
DAPT-30/0.2E
DAPT-5/0.2E
Basic info
Brand Wone
Model NO. WDJB-3000SM Digital-Analog Integrated Relay Protection Tester
AC current 30A
Power ≥350VA
Series WDJB-3000SM
Product Detail

Description

WDJB-3000SM digital-mode integrated relay protection tester with 12 roads of small signal output, 10 sets of switch input, 8 sets of switch output nodes, output and reception functions of 9-1,9-2, FT3, GOOSE, and fully supports all standards of the tested equipment.

Specifications

AC current source
Number of channels 6 roads
amplitude (RMS)  6 (0~30A) / phase
Resolution 0~0.3A:0.03mA;0.3~3A:0.3mA;3~30A:3.0mA
Accuracy 0.05A~30A: 0.1%
Frequency Static  0~1000Hz
Dynamic at 0~3000Hz
Resolution 0.001Hz
accuracy ≤0.001Hz
Harmonic distortion rate 0.5%
Response speed 50uS
Capability
current value 5A 30A
power ≥75W ≥450W


output time
current value ≤10A 10A~20A 20A~30A
time long ≥100S ≥20S


DC electric voltage source
Number of channels  4 road + 1 road independent DC power supply
Size  4,176V / phase
Resolution  5mV
accuracy ≤0.5%
Wave coefficient 0.5%
Capability
magnitude of voltage 110V 176V
power ≥80W ≥120W
output time
magnitude of voltage 0~176V
time long


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!