• WDBR-IV Accuracy 0.2 Transformer Capacity and No-Load Tester
  • WDBR-IV Accuracy 0.2 Transformer Capacity and No-Load Tester
WDBR-IV Accuracy 0.2 Transformer Capacity and No-Load Tester
$1500.00
Model
WDBR-IV
Basic info
Brand Wone
Model NO. WDBR-IV Accuracy 0.2 Transformer Capacity and No-Load Tester
Output Voltage 0~10V
Output current 0~10A
Series WDBR-IV
Product Detail

Description

This instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the active transformer capacity tester and the transformer characteristic parameter tester. In the characteristic test, it can be tested by the traditional two-meter method or the standard three-wire four-wire tester. The phase system test can not only compare the parameters with the traditional test method, but also accurately measure the parameters. It can accurately measure a series of power frequency parameters such as capacity, type, no-load current, no-load loss, load loss, impedance voltage, etc. of various transformers. The accuracy of capacity and characteristic test results is 100%. The capacity measurement range: 10kVA~100000kVA.

Specifications

Interal power output range
Voltage 0~10V
 Current 0~10A
 Characteristic test power input range
 Voltage 0~750V
  Current  0~100A
Test accuracy
Voltage, current ±0.2%
Power ±0.5% (CosΦ>0.1), ±1.0% (0.02<CosΦ<0.1)
Working temperature -20℃~+60℃
 Charger power requirements  Mains AC160V~265V
Insulation degree
  (1)The insulation resistance of the capacity test, voltage and current input points to the chassis is greater than or equal to 100MΩ
 (2) The charging power input to the chassis is subjected to a power frequency of 2KV (effective value), and the test time is 1 minute.
Volume  32cm×24cm×13cm
Weight 2.5㎏




Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l