Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV

  • Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV

Key attributes

Brand ABB
Model NO. VD4G generator circuit breaker Small footprint, full protection for generator applications
Rated voltage 15kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series VD4G

Product descriptions from the supplier

Description

Description:

ABB offers its new vacuumgenerator circuit breakers at 15 kV,4000 A, 63 kA in accordance to thenew Dual Logo IEEE/IEC 62271-37-013 standard to satisfy yourbusiness needs in power generation applications.

Features:

Protect your assets

  • Use a solution completely inaccordance with the latest global standards - IEC as well as IEEE

  • Count on a generator circuit breakersuitable for all highly demanding conditions, including out-of-phase condition and island mode

  • Be safe thanks to a completely testedsolution for DC-component up to130%, so no need to add any time delay in the protection

Maximize your output

  • Experience the easy installation/integration of VD4G, thanks to itsinterfaces and dimensions equivalentto the standard version VD4

  • Accelerate your projects with theoutstanding technical support grantedby our Field Application Engineeringm team

Optimize your investment

  • Choose ratings that fit your needs from 25/16 kA @ 15 kV to 63/50 kA @ 15 kV

  • Take advantage of using the samecompact switchgear setup like inpower distribution systems

Technical characteristics:

Standards IEEE/IEC 62271-37- 013

 

Documentation Resource Library
Public.
VD4G generator circuit breaker Small footprint, full protection for generator applications
Catalogue
English
FAQ
Q: What is a generator circuit breaker?
A: A generator circuit breaker (GCB) is a specialized switchgear device used in power generation systems to safely connect or disconnect a generator from the electrical grid or load. It is designed to interrupt high fault currents, protect the generator from overloads, short circuits, and other electrical faults, and ensure reliable operation during normal and abnormal conditions.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 580000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 580000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Electrical House (eHouse) Solutions
    Reduce site complexity, improve lead timeABB eHouses are prefabricated transportable substations, designed to house medium voltage and low voltage switchgear, critical power equipment and automation cabinets.An eHouse solution is a cost effective, risk reduced alternative to conventional concrete block and brick construction. Each eHouse module is custom engineered to meet application requirements with respect to equipment layout, site footprint limitations and logistics considerations.Installat
    04/16/2025
  • Improve speed to deployment Modular prefabricated and pre-engineered solutions
    Reduce site works and risk of schedule delays and cost overrunsOverview:With a complicated data center project that has short delivery timelines, prefabricated modular solutions and pre-engineered modular solutions may be the answer.Modular solutions are ideal for enterprise, colocation, edge and cloud data centers, where project replicability and expandability are critical, alongside fast deployment time.Reduce risk by leveraging prefabricated and integrated solutions:Fast track projects with p
    04/16/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.