10kV Three-phase oil-immersed distribution transformer in China

Add us on Google
  • 10kV Three-phase oil-immersed distribution transformer in China

Key attributes

Brand ROCKWILL
Series S11
Rated voltage 6-11kV
Rated frequency 50/60Hz
Rated capacity 30-1600kVA
Connection Group Dyn11、Yyn0
Description

The 10kV Three-phase Oil-immersed Low-loss Energy-saving Distribution Transformer, supplied by a professional China Manufacturer with flexible OEM/ODM customization, is a core component of modern power distribution networks, engineered for superior efficiency and reliability. Utilizing advanced core materials and an optimized design, it significantly reduces no-load and load losses compared to standard models. Custom specifications can be realized through our OEM/ODM service.

This transformer delivers substantial energy savings and lower operating costs over its lifespan, making it an economically smart and environmentally responsible choice for utilities and industries aiming to enhance the sustainability of their power infrastructure.

Product Showcase Video

Product model

  • S: Three-phase Oil-immersed
  • 11: Performance Level
  • M: Fully Sealed
  • □: Rated Capacity (kVA)
  • □: Voltage Class (kV)

Conditions of use

  • Altitude: No more than 1000m, indoor or outdoor.
  • Ambient temperature: The highest ambient air temperature is +40℃, the highest daily average temperature is +30℃
  • maximum annual average temperature is +20℃, and the minimum temperature is -25℃.
  • Transformers can be provided to operate under special conditions according to user requirements.

Key Technical Features

  • Advanced Low-Loss Core Design:Constructed with high-grade, low-loss amorphous alloy or high-permeability silicon steel core, which dramatically reduces no-load (core) losses, the primary source of energy waste in transformers.
  • Optimized Energy Efficiency:Meets or exceeds stringent energy efficiency standards (such as IE3, IE4 or Chinese GB Standard). Its design minimizes total ownership cost by prioritizing high performance at both full and partial loads.
  • Robust Oil-Immersed Construction:The time-tested oil-immersed design provides excellent insulation and heat dissipation, ensuring stable operation, a long service life, and reliable performance under fluctuating load conditions.
  • Reduced Operating Costs:The significant reduction in energy losses translates directly into lower electricity bills, offering a rapid return on investment and a smaller carbon footprint.
  • Durable and Reliable Performance:Features a fully sealed tank to prevent oil oxidation, corrugated radiators for effective cooling, and high-quality components to ensure minimal maintenance and maximum uptime.

Performance Parameters

Rated Capacity

Voltage Combination and Tapping Range

Connection Group

No-load Loss (W)

Load Loss at 120℃ (W)

Short-circuit Impedance %

No-load Current %

High Voltage (kV)

Tapping Range %

Low Voltage (kV)

30

6

6.3

6.6

10

10.5

11

 

± 5

± 2×2.5

 

0.4

Dyn11

Yyn0

100

630/600

4.0

2.3

50

130

910/870

2.0

63

150

1090/1040

1.9

80

180

1310/1250

1.9

100

200

1580/1500

1.8

125

240

1890/1800

1.7

160

280

2310/2200

1.6

200

340

2730/2600

1.5

250

400

3200/3050

1.4

315

480

3830/3650

1.4

400

570

4520/4300

1.3

500

680

5410/5150

1.2

630

810

6200

4.5

1.1

800

980

7500

1.0

1000

1150

10300

1.0

1250

1360

12000

0.9

1600

1640

14500

0.8

Note: for transformers rated at 500 kva and below, the load loss values above the diagonal lines in the table apply to dyn 11 or yzn 11 connection groups, and the load loss values below the diagonal lines apply to yyno connection groups.

Typical Application Scenarios

  • Public Utility Grids: Widely used in 10kV distribution substations for stepping down voltage to supply residential communities, commercial districts, and public facilities.
  • Industrial Power Supply: Serves as a dedicated power source for factories, manufacturing plants, and industrial parks where continuous operation and energy cost control are critical.
  • Renewable Energy Integration: Functions as a grid-connection point for distributed generation sources like solar and wind farms, where high efficiency is crucial for maximizing energy yield.
  • Infrastructure Projects: Provides reliable power for key infrastructure such as water pumping stations, railway systems, and airports, ensuring operational stability and energy savings.

Why choose Rockwill?

  • 20+ years experienced China Manufacturer, full production chain, OEM/ODM available
  • IEC / ANSI / IEEE certified, third-party lab verified, ISO management system
  • Digital quality control, stable performance & competitive cost
  • Global service network across 100+ countries, one-stop grid solution & technical support

Solutions - Distribution Transformer

  • Innovative Application Solutions for Single-Phase Distribution Transformers in U.S. Rural and Suburban Grid Modernization
    1 Rural Grid Challenges and Technical Advantages of Single-Phase TransformersThe U.S. rural and suburban grid faces critical challenges: aging infrastructure and low load density result in inefficient power supply, with line losses reaching 7%–12%—significantly higher than urban grids (4%–6%). Over 60% of rural areas exceed the 300-meter power supply radius standard, causing widespread voltage instability (peak voltage drops of 15%–20%). Three-phase transformers in low-load-density areas (<2
  • Single-Phase Distribution Transformers: The Key to Flexible and Efficient Deployment of EV Charging Infrastructure
    Single-Phase Distribution Transformers: The Key to Flexible and Efficient Deployment of EV Charging InfrastructureAmid the rapid deployment of EV charging infrastructure, overcoming grid limitations and achieving cost-effective flexible layouts has become critical. Traditional three-phase power supply solutions often face challenges like lengthy installation cycles and extensive modifications, particularly struggling in imbalanced distributed scenarios. Single-phase distribution transformers are
  • Advanced Solutions for Single Phase Distribution Transformers in the US Market
    Ⅰ. Characteristics of the U.S. Power System & Technical Requirements for Single-Phase TransformersThe U.S. power system utilizes a 480V/277V three-phase four-wire system as the primary power supply standard for commercial facilities, while residential applications adopt a 120V/240V single-phase three-wire system.Technical Parameters: Input Voltage: Must cover a fluctuation range of ±10% (e.g., 277V ±27.7V). Output Voltage Accuracy: Controlled within ±3%. Insulation System: Must meet Class H

Case Studies - Distribution Transformer

  • Rockwill Delivers Customized Pad-Mounted Transformers to Support Key Infrastructure Project in Afghanistan
    Project OverviewIn March 2021, Rockwill prepared a batch of pad-mounted transformers for shipment to Afghanistan. These units were designed to meet the specific requirements of a local infrastructure project, demonstrating our capability to deliver tailored solutions for challenging environments and diverse operational needs.Technical SolutionThe shipment included pad-mounted transformers with a capacity range of 25kVA to 2500kVA and a voltage rating of 20/0.4kV. Engineered for reliability and e
  • Rockwill 2500kVA Step up Transformer Success in Namibia
    01 General Overview: Namibia 20 MW PV Power Station Project1.1 Project BackgroundNamibia possesses some of the world’s best solar resources, with average Global Horizontal Irradiation (GHI) exceeding 2400 kWh/m². However, PV plants are often located in the central plateau and arid regions where the natural environment is extremely harsh. The project sites are situated at altitudes between 1500m and 2000m and exposed to IEC 60721-3-3 Class 3S4 environments (Severe Sand and Dust).In the

Documentation Resource Library Distribution Transformer

Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
H61 HV/LV distribution transformer
Restricted
H61 HV/LV distribution transformer H61 HV/LV distribution transformer
Catalogue
English
PDF
H59 HV/LV distribution transformer
Restricted
H59 HV/LV distribution transformer H59 HV/LV distribution transformer
Catalogue
English
PDF

Frequently asked questions

This distribution transformer meets or exceeds IE3, IE4 and relevant Chinese GB energy efficiency standards.

The fully sealed tank avoids oil oxidation. Together with corrugated radiators, it ensures good cooling performance and less maintenance.

Yes. As a China Manufacturer, we provide OEM/ODM service for special environmental and technical requirements.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register