• Single-phase 12 kW Small diesel generator
  • Single-phase 12 kW Small diesel generator
  • Single-phase 12 kW Small diesel generator
  • Single-phase 12 kW Small diesel generator
Single-phase 12 kW Small diesel generator
discuss personally
Model
DMD15000LE
Basic info
Brand Wone
Model NO. Single-phase 12 kW Small diesel generator
Phases Single-phase
Engine Max Output Power 16/3600 kW/rpm
Generator Rated Power 12kW
Generator Rated Voltage 230V
Generator Capacity 40L
Series Small diesel generator set
Product Detail

Description:

  •  Adopt double-cylinder V-shaped structure, strong power.

  •  Large silencer, dynamic balance shaft, low noise unit design, shell and frame with shock absorption function. 

  • Large capacity fuel tank to ensure long-term continuous work.

  • Non-fuse circuit breaker provides overload protection, capacitive voltage regulator to ensure stable voltage output.

  • Directional wheel and universal wheel structure, easy to move.

Parameter:

image.png

Feature:

Two - cylinder air - cooled engine - compact structure:

It is a four - stroke direct - injection air - cooled engine with excellent transmission mechanism design. It has the characteristics of light weight, small volume, and low failure rate. The high - precision fuel injection pump enables the fuel to burn fully and save fuel.

企业微信截图_17346584123890.png

High - strength open - frame structure - convenient maintenance:

It uses high - quality metal pipes, American - style design, and the cross - frame is welded as a whole, with high safety factor, good heat dissipation performance, convenient maintenance, and is suitable for various engineering construction applications.

OTC automatic welding:

The frame is more solid, the joints are not easily broken, safer and more reassuring.

企业微信截图_17346584986180.png

Humanized brake universal wheels - convenient to move:

The brake universal casters can be temporarily fixed when in use, and can be switched to the rotation mode at any time when pushed. Its structure allows horizontal 360 - degree rotation, with flexible rotation, convenient for outdoor construction movement. The material of the wheels is nylon, which has the characteristics of wear - resistance and long service life.

企业微信截图_17346587076318.png

Multi - function digital display voltmeter - one - key display:

The voltage, frequency, and usage time of the generator can be displayed with one key, allowing you to know the usage status of the generator at any time. Equipped with over - current and over - load protection devices, it can independently protect the engine.

企业微信截图_17346589105626.png


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!