• Ladle refining furnace transformer(distribution transformer)
Ladle refining furnace transformer(distribution transformer)
discuss personally
Model
SLR11-20000
Basic info
Brand Vziman
Model NO. Ladle refining furnace transformer
Rated capacity 20000kVA
Series Ladle refining furnace transformer
Product Detail

Description
The ladle refining furnace (LF furnace) transformer is a core equipment in the iron and steel smelting industry, primarily used to provide stable electric energy for the molten steel refining process. Its performance directly impacts the efficiency, energy consumption, and safety of steel production. With the development of electric furnace steelmaking technology, especially the popularization of large-scale LF furnaces above 40 tons, the design and technical standards of transformers have gradually shifted towards high efficiency and internationalization, forming a technological trend centered on energy conservation, reliability, and low maintenance.

Key Features

Energy Efficiency: Low no-load/load losses, optimized impedance voltage; uses Baowu/Nippon Steel 30Z130/30Q130 silicon steel. 

Reliability: 30+ year design life; fully oblique core joints, German Georg shear (<0.02mm burr), low-magnetic steel clamping. 

Overload Capability: Stable operation at 120% load via oxygen-free copper windings, small oil gaps, and cooling cylinder structures. Low Maintenance: 10+ years maintenance-free; vacuum oil injection, anti-aging seals, and folded plate tanks prevent leaks.

Components

Core

  • Material: Uses Baowu 30Z130 or Nippon Steel 30Q130 silicon steel, matching materials used in developed countries.

  • Structure: Full oblique-joint lamination design with low-magnetic steel plate pull rods for clamping, eliminating punching holes to ensure uniform magnetic flux density across core sections without distortion.

  • Processing: German Georg shearing line controls burrs ≤0.02mm (standard ≤0.05mm) and length tolerance ≤0.2mm/m, improving lamination factor to reduce local overheating, noise, and no-load losses.

Windings

  • Material: Oxygen-free copper magnet wires (P<0.017241 at 20°C) with precise insulation paper wrapping.

  • Design: Small oil gaps, internal/external oil baffles, and cooling cylinder structure enhance axial/radial stability, overload capacity, and reduce losses.

  • High-Voltage Solutions: "8"-type coils for one-time winding in high-load voltage regulation and 110kV-grade products, improving strength and reducing eddy current losses.

Body

  • Structure: Laminated wood for all wooden parts to enhance lead frame rigidity; upper/lower pressboards made of insulation boards or epoxy molded parts to increase conductor-to-ground insulation distance and reduce "window height" dimensions.

  • Insulation: Imported cardboard for main insulation, multi-coil integral assembly, and Norwegian steam drying equipment to ensure thorough drying without damaging insulation.

Oil Tank

  • Design: Folded plate structure minimizes welds, tested for positive/negative pressure to ensure sealing reliability.

  • Loss Reduction: Low-magnetic steel or magnetic shielding in strategic positions reduces additional losses from busbar magnetic fields on the tank wall, effectively preventing leakage and reducing losses.

Assembly

  • Process: Hydraulic compaction after body drying and vacuum oil injection to eliminate winding bubbles and reduce partial discharge.

  • Sealing: Anti-aging sealing materials address oil leakage; control circuits (gas relay, thermometers, etc.) integrated into a top-mounted junction box for a sleek, unified appearance.

Accessories

  • Cooling: YS1 water-coolers or stainless steel spiral plate coolers; anti-pollution high-voltage bushings increase creepage distance.

  • Tap Changers: Advanced "M" or "V" type from leading manufacturers with remote display and control interfaces.

  • Oil System: Karamay naphthenic anti-aging transformer oil in fully enclosed tanks with pressure relief valves and diaphragm conservators for complete protection.

Transformer Maintenance and Technical Assurance Summary

For transformer maintenance, long-distance transported core-hanging products require post-arrival checks to address loose fasteners and facilitate user acceptance, while routine overhauls should focus on replacing mechanical wear parts (e.g., pumps) per the original cycle. Quality assurance includes designing windings with a 20% overload margin (e.g., 24000kVA for a 20000kVA-rated LF furnace transformer) to ensure stable operation at 120% load, with impedance voltage ≤8% and heat load calculations based on the higher capacity. Anti-impact and short-circuit measures enhance coil axial/radial stability via high-voltage-grade wires, precise drying, hydraulic compaction, and multi-support structures. To guarantee 20-year maintenance-free operation, the design uses Karamay naphthenic oil in fully enclosed tanks with diaphragm conservators, anti-aging seals, and regular oil chromatographic analysis. Key improvements include Baowu/Nippon Steel silicon steel cores with ultra-low burr shearing, oxygen-free copper windings with small oil gaps, laminated wood bodies, folded-plate tanks with magnetic shielding, and integrated control systems. Future trends for ore-heating furnaces include single-phase transformers with side-mounted water-cooling for ≥15000kVA models, while maintenance prioritizes non-intrusive monitoring via oil analysis to reduce costs and contamination risks.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!