• Spring Operating Mechanism (Disconnector mechanism)
Spring Operating Mechanism (Disconnector mechanism)
discuss personally
Model
SOM-24
Basic info
Brand Switchgear parts
Model NO. Spring Operating Mechanism (Disconnector mechanism)
Motor Voltage 24V
Series SOM
Product Detail

Technical Parameter:


ITEM

UNIT

VALUE

Mechanical Life time

TIMES

3000

Motor Voltage

AC/DC

24 48 110 220

Electroplating


RoHS

Rotation Angle

°

45-80°

Wire


Depend on customer's demand

Spring quantity

PIECE

1

Maunal or Motorized


Both OK

Usage Environment:


  1. Altitude:Less than 3000m(The most 5000m)

  2. ambient temperature:-40℃--40℃,The average daily temperature is not higher than 35°C

  3. verage daily relative humidity:95%    Monthly average relative humidity: 90% 

      Daily average saturated vapor pressure: ≤2.2×10-3Mpa Monthly average saturated vapor pressure: ≤1.8×10-3Mpa

  4. Earthquake intensity: no more than 8 degrees

  5. Horizontal acceleration: synthetic seismic wave 0.25g, sinusoidal resonance beat wave 0.15g

  6. Low temperature and cold area: no SF6 gas application, no need to consider the low temperature operation of SF6 gas, and it can operate normally at -45C.

  7. Plateau area: no need to consider the influence of plateau atmospheric pressure on insulation performance

  8. Strong wind and sand area: The safety protection level of the solid insulation ring main unit is IP67, and the control circuit room adopts special treatment to ensure long-term operation in strong wind and sand areas.

  9. Coastal wet areas: epoxy resin sealing, anti-moisture, anti-salt spray corrosion, to ensure long-term use in coastal areas. Areas with high environmental protection requirements: The impact of SF6 gas on atmospheric warming has been highly regarded, and the solid ring main unit has eliminated SF6 gas, which does not cause any pollution and harm to the environment and people.


Drawing:
Disconnector mechanism for solid.png

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Substance of Second - harmonic Restraint in Overcurrent ProtectionThe substance of second - harmonic restraint in overcurrent protection is to use the second - harmonic component to judge whether the current is a fault current or an excitation inrush current. When the percentage of the second - harmonic component to the fundamental - wave component is greater than a certain value, it is judged to be caused by the excitation inrush current, and the overcurrent protection is blocked.Therefore, the
Leon
07/18/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi