SF6 brīvā gāza izolētais pārslēgspēks primārajai sadalei

  • SF6-free gas-insulated switchgear for primary distribution

Galvenie atribūti

Zīme ABB
Modela numurs SF6 brīvā gāza izolētais pārslēgspēks primārajai sadalei
Nominalais spriegums 12kV
Nomīnālā frekvence 50/60Hz
Sērija PrimeGear ZX2

Produktu apraksti no piegādātāja

Apraksts

Klientu priekšrocības:

Saderība ar IEC standartiem un F-gāzes regulējumu

  •  Saderība ar IEC standartiem un ar ES F-gāzes regulējumu (ES) 2024/573.

  •  Augstas reitings līdz 2500A. Viena šķidraine modulāra un kompakta zemas spiediena izstrāde, balstīta uz dabiskām izcelsmes gāzēm (bez SF6).

  •  Pārtraukuma pakalpojumu nepārtrauktība LSC 2A  un sadalījuma klase PM*.

Uzticība un elastība 

  • Kompakta un modulāra izstrāde telpas optimizācijai. 

  • Lieliska uzturība nav nepieciešama, jo visi augstsprieguma daļēji ir pastāvīgi aizsargāti gāzu rezervuarā un aizsargāti no piesārņojuma, mitruma, ārējiem objektiem un citām vides ietekmēm.

  • Zema spiediena dizainā dēļ apgaismojuma aparāts var palikt darbā līdz remontam, pat ja notiek neliela izkape. 

  • Apgaismojuma aparātam var pievienot monitoringu un diagnostiku (piemēram, temperatūras, gāzes, daļēja izkāpe) lai sekotu pārvaldītajām vērtībām. Automatizācijas un kontrolēšanas funkcijas, balstītas uz strāvas un sprieguma sensoriem un IEC 61850 protokolu, ļauj pielāgot to ražošanas fāzē un mainīgajām slodzēm darbības laikā.

  • Labāk zināma un pierādīta vakuuma izolētājs tipa VD4X. 

  • Ārējā konusa kabeļu beigu sistēma.

Drošība 

  •  Augsts operators drošības līmenis ar priekšējo, sānu un aizmugurējo loku aizsardzību,  sertificēta AFL(R) 40kA 1s (saskaņā ar IEC 62271-200). 

  • Ievietojamās šķidraines tehnoloģija un rūpnīcā montēta spiediena atlīdzināšanas kanāls ļauj drošu, ātru un vie glu instalāciju vietas. 

  • Ar apgaismojuma aparāta shēmu un darbības pārvaldību priekšējā panelī, nav nepieciešams atvērt durvis manuālai darbībai, kas padara apgaismojuma aparātu lietotājam draudzīgu.

  •  Plašs monitoringa un diagnostikas funkciju spektrs drošai un uzticībai darbībai. Visi pārslēgšanas ierīces ir ar dzinēju vadāmas un  var tikt pārvaldītas attālināti.

  •  Mehāniskie un elektriskie bloķētāji novērš apgaismojuma aparāta paneļu nepareizo darbību.

Tehniskie parametri:

Konstrukcijas diagramma:

 

 

Dokumentu resursu bibliotēka
Public.
SF6-free gas-insulated switchgear for primary distribution
Catalogue
English
FAQ
Q: What’s the difference in the circuit breaker for air-insulated vs gas-insulated?
A: Air-insulated switchgear circuit breaker is typically removable or withdrawable. The circuit breaker is based on vacuum circuit technology. In the gas-insulated, it is fixed mounted. The function of withdraw is provided by a separate disconnecting switch. Typically, a three-position switch with connected, disconnected, and ready-to-earth position.
Q: What’s the difference in the circuit breaker for air-insulated vs gas-insulated?
A: Air-insulated switchgear circuit breaker is typically removable or withdrawable. The circuit breaker is based on vacuum circuit technology. In the gas-insulated, it is fixed mounted. The function of withdraw is provided by a separate disconnecting switch. Typically, a three-position switch with connected, disconnected, and ready-to-earth position.
Q: What are the maintenance requirements associated with the air-insulated switchgear (AIS) vs gas-insulated (GIS)?
A: Gas-insulated switchgear requires very low maintenance as all high voltage parts are permanently protected in a gas tank from soiling, humidity, entry of foreign bodies and other environmental influences. Primary, the drives located outside gas compartment require inspection and maintenance. On the other hand, gas-insulated switchgear repair requires additional training (e.g. for gas works) and the replacement or parts may not be as easily. In the air-insulated switchgear visual inspection is recommended in regular intervals, maintenance of power parts is given in installation, operation and maintenance manual (1VLM000363).
Q: What smart solutions are available for ABB’s AIS portfolio?
A: ABB’s switchgear smart solutions are designed to help our customers make data-driven decisions. Our customers can benefit from a wide range monitoring, diagnostic, automation and control features for their ABB’s air-insulated medium voltage switchgear. Contact our sales team to learn more about ABB’s smart solutions for each of our switchgear.
Izpratāties ar savu piegādātāju
Tuvērtnica
Punktuālais piegādes rādītājs
Atbildes laiks
100.0%
≤4h
Uzņēmuma pārskats
Darba vieta: 20000m² Kopējais darbinieku skaits: Augstākā gada eksportvērtējums USD: 580000000
Darba vieta: 20000m²
Kopējais darbinieku skaits:
Augstākā gada eksportvērtējums USD: 580000000
Pakalpojumi
Biznesa veids: Pārdošana
Galvenās kategorijas: Augstsprieguma elektroierīki/Zemā sprieguma elektroierīces
Dzīvesilga garantija
IEE-Business iekārtu iegādes, lietošanas, uzturēšanas un pēcpārdošanas visdzīves cikla aprūpes pārvaldības pakalpojumi, nodrošinot elektroiekārtu drošu darbību, nepārtrauktu kontroli un drošu elektroenerģijas patēriņu
Iekārtu piegādātājs ir izgājis platformas kvalifikācijas sertifikāciju un tehnisko novērtējumu, nodrošinot atbilstību, profesionalitāti un uzticamību avotā

Saistītie produkti

Saistītās zināšanas

Saistītās risinājumi

Vēl neesat atradis piemērotu piegādātāju Liet ļaujiet apstiprinātiem piegādātājiem atrast jūs Saņemt piedāvājumu tūlīt
Vēl neesat atradis piemērotu piegādātāju Liet ļaujiet apstiprinātiem piegādātājiem atrast jūs
Saņemt piedāvājumu tūlīt
Pieprasījums
Lejupielādēt
Iegūt IEE Business lietojumprogrammu
Lietojiet IEE-Business lietotni lai atrastu aprīkojumu iegūtu risinājumus savienotos ar ekspertiem un piedalītos nozares sadarbībā jebkurā laikā un vietā pilnībā atbalstot jūsu enerģētikas projektus un biznesa attīstību