RNM1-8 Household Metal Distribution Box

  • RNM1-8 Household Metal Distribution Box
  • RNM1-8 Household Metal Distribution Box
  • RNM1-8 Household Metal Distribution Box
  • RNM1-8 Household Metal Distribution Box
  • RNM1-8 Household Metal Distribution Box

Key attributes

Brand Switchgear parts
Model NO. RNM1-8 Household Metal Distribution Box
Mounting type Concealed installation
number of circuit 8
Series RNM1

Product descriptions from the supplier

Description

The RNM1 series metal cabinet residential distribution box is a dual-tone residential distribution box introduced by  Electric. Its details convey humanistic care, and meticulous craftsmanship achieves a light luxury aesthetic. The unparalleled golden ratio and dual-tone design seamlessly blend with any home style, captivating the heart at every glance. It offers a joy of innovation and an extraordinary life

The distribution box is a distribution box with plastic cover and metal box, mainly used for
1.Power distribution system: electrical installation, supporting and house renovation and decoration of building electrical power distribution system.
2.Installation method The metal box is matched with the plastic cover, which is especially suitable for the concealed installation of the distribution box in the construction and decoration works.
3.Stylish appearance design is suitable for high-end residential buildings, hotels, office buildings and other places that show modern life taste.
4.The products that meet the standards have first obtained 3C certification and meet the standards of GB17466.1 and GB17466.24

Concealed size

Item

Specification

Panel size(mm)

Bottom box size(mm)

RNM1-8

8

222x210x100

196x190x85

RNM1-12

12

294x210x100

268x190x85

RNM1-16

16

366x210x100

340x190x85

RNM1-20

20

438x210x100

412x190x85

RNM1-24

24

294x335x100

268x315x85

RNM1-32

32

366x335x100

340x315x85

RNM1-40

40

438x335x100

412x315x85

RNM1-16D

16

366x230x100

340x210x85

RNM1-20D

20

438x230x100

412x210x85

Open installation size

Item

Specification

Panel size(mm)

Bottom box size(mm)

RNM1-8M

8

222x210x100

222x210x85

RNM1-12M

12

294x210x100

294x210x85

RNM1-16M

16

366x210x100

366x210x;85

RNM1-20M

20

438x210x100

438x210x85

RNM1-24M

24

294x335x100

294x335x85

RNM1-32M

32

366x335x100

366x335x85

RNM1-40M

40

438x335x100

438x335x85

RNM1-16DM

16

366x230x100

366x230x85

RNM1-20DM

20

438x230x100

438x230x85

FAQ
Q: What daily maintenance work is required for a Household Metal Distribution Box and what is the cycle?
A:

Daily maintenance is divided into regular inspection and irregular patrol inspection:

·Monthly Inspection: ① Check if the box door is tightly closed, and if there is any peculiar smell/abnormal noise; ② Clean dust on the box surface and keep the heat dissipation holes unobstructed;

· Quarterly Inspection: ① Tighten wiring terminals to prevent loosening and heating; ② Test the residual current device (press the test button) to ensure normal function;

·Annual Inspection: ① Check if the anti-rust coating of the box falls off, repaint in time; ② Evaluate circuit load and adjust shunt configuration.

Q: What is the core function of a Household Metal Distribution Box and what advantages does it have over plastic distribution boxes?
A:

Household Metal Distribution Box is the control hub of a home's power system, used for centralized installation of circuit breakers and residual current devices (RCDs), realizing power distribution management and safety protection for circuits such as lighting, sockets, and air conditioners.

Compared with plastic distribution boxes, its advantages are as follows:

· Sturdy Structure: Cold-rolled steel material is impact-resistant and deformation-proof, with a service life of 15-20 years;

· Safety Protection: Has electromagnetic shielding function to prevent circuit interference and stronger flame retardancy;

· Good Heat Dissipation: Metal material conducts heat quickly, avoiding tripping of internal equipment due to overheating.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.