RCW-S21.9M 21.9kV MV foras vacuum recloser

  • RCW-S21.9M 21.9kV MV outdoor vacuum recloser

Attributa principalia

Marca ROCKWILL
Numerus Modeli RCW-S21.9M 21.9kV MV foras vacuum recloser
Votum nominatum 21.9kV
currus electricus nominatus 630A
currentis rumpendi nominale in circuitu commutato 16kV
Tensio sustentans frequentia industriale 70kV/min
Voltage tolerabile impulsum fulminis nominale 170kV
Manuale clausura Yes
Series RCW

Descriptiones productorum a fornitori

Descriptio

Describtiō :

Sēriēs RCW automatīcī circuit reclosers possunt adhibērī in aeriālibus distribūtiōnis līnīs sicut et in distribūtiōnis substationibus pro omnibus voltōrum classibus ab 11kV usque ad 38kV in 50/60Hz potentiā systēmā. Et eius ratiō cūrrentis potest attingere 1250A. Sēriēs RCW automatīcī circuit reclosers integrant functionēs controlis, prōtectionis, mēnsūrātionis, communicationis, fault detectionis, on-line monitoringis claudendi vel aperiendi. Sēriēs RCW vacuum recloser prīncipaliter combinatur cum integratione terminālis, currentis transformer, permanentis magneticī actuatoris et eius recloser controller.

Characteristīcae :

  • Gradus optionales disponibiles in ratiō cūrrentis ambitu.

  • Cum protectione relē et logica pro selectiōne usūris.

  • Cum protocolīs communicationis et I/O portīs pro selectiōne usūris.

  • PC software pro testandō, setup, programmatione, update controlleris.

Parametri :

image.png

image.png

Dimensiones externae

企业微信截图_17105494892828.png

Requisitum ambientale

image.png

Demonstrātiō productī

Quae sunt insulationis faultī outdoor vacuum reclosers et eorum solutionēs?正方型 单相.png

Insulationis Faultī :

Insulator Flashover :

  • Mundāre Insulators: Pro insulatoribus qui experientur flashover propter superficiālem contaminationem, mundātio regularis necessaria est. Instrumenta specialia mundandi insulatorēs, sicut pincētae mundandi insulatorēs aut pistola aquae altae pressionis, uti possunt. Post mundātionem, anti-flashover coatinges super superficies insulatorum aspergi possunt ad augmentandam eorum resistentiam ad contaminationem.

  • Substituere Insulators: Si insulatorēs ostendunt diminutionem fortitudinis insulationis propter fulminātōrum ictūs vel alias causās, et exhibent fīssūras vel damna manifesta, substituendi sunt prompte. In substituendo insulatorēs, eligantur qui satisfaciant requirementibus voltōrum et fortitudinis mechanicārum equipmentī.

Insulationis Senectūs :

  • Testare Performance Insulationis: Utere testeribus resistance insulationis, testeribus dielectricae loss, aliisque instrumentis ad regularem testandum performance insulationis materialium insulationis. Quando declinatio performance insulationis detecta est, causas senectūtis analyzanda sunt.

  • Substituere Componentes Insulationis: Si senectūs insulationis gravis est, sicut quando phaenomena partialis disiecti observantur, componentes insulationis senescentes (sicut bushings insulationis, supports insulationis) substituendi sunt prompte. Praeterea, meliora conditionem operativam equipmentī, sicut per augmentandam ventilationem et restringendam humiditatem, ad retardandam processum senectūtis insulationis.

Resolutiones Insulationis Faultī :

Insulator Flashover :

  • Mundāre Insulators: Pro insulatoribus qui experientur flashover propter superficiālem contaminationem, mundātio regularis necessaria est. Instrumenta specialia mundandi insulatorēs, sicut pincētae mundandi insulatorēs aut pistola aquae altae pressionis, uti possunt. Post mundātionem, anti-flashover coatinges super superficies insulatorum aspergi possunt ad augmentandam eorum resistentiam ad contaminationem.

  • Substituere Insulators: Si insulatorēs ostendunt diminutionem fortitudinis insulationis propter fulminātōrum ictūs vel alias causās, et exhibent fīssūras vel damna manifesta, substituendi sunt prompte. In substituendo insulatorēs, eligantur qui satisfaciant requirementibus voltōrum et fortitudinis mechanicārum equipmentī.

Insulationis Senectūs :

  • Testare Performance Insulationis: Utere testeribus resistance insulationis, testeribus dielectricae loss, aliisque instrumentis ad regularem testandum performance insulationis materialium insulationis. Quando declinatio performance insulationis detecta est, causas senectūtis analyzanda sunt.

  • Substituere Componentes Insulationis: Si senectūs insulationis gravis est, sicut quando phaenomena partialis disiecti observantur, componentes insulationis senescentes (sicut bushings insulationis, supports insulationis) substituendi sunt prompte. Praeterea, meliora conditionem operativam equipmentī, sicut per augmentandam ventilationem et restringendam humiditatem, ad retardandam processum senectūtis insulationis.



Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

Solutiones Relatae

Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum