• Low voltage pole mounted circuit breaker D165T with digital trip unit
Low voltage pole mounted circuit breaker D165T with digital trip unit
discuss personally
Model
D165/4
Basic info
Brand Wone Store
Model NO. Low voltage pole mounted circuit breaker D165T with digital trip unit
Rated normal current 165A
Rated frequency 50/60Hz
Series D
Product Detail

Description

These breakers are designed to operate within low - voltage networks, typically handling voltages of 600V AC or less and 750V DC or less. Their primary function is to interrupt the flow of current when faults such as overloads, short - circuits, or under - voltage conditions occur. They are widely used in various applications, including industrial plants, commercial buildings, and residential electrical systems. In industrial settings, they protect large - scale machinery and equipment from electrical malfunctions. In commercial buildings, they ensure the safety of lighting, heating, and cooling systems. In residential areas, they safeguard household appliances and wiring.

Features

  • Safe Circuit Interruption:LV circuit breakers are engineered to open and close circuits safely. This is vital as improper circuit interruption can lead to electrical arcs, which may cause fires or damage to equipment. They can handle the high - energy surges associated with breaking an electrical circuit without endangering the surrounding environment.

  • Repeated Breaking Operations:They are capable of performing breaking operations repeatedly. This feature ensures long - term reliability. In a power system where faults may occur occasionally, the breaker needs to be able to respond multiple times without degradation in performance. For example, in an industrial facility with fluctuating electrical loads, the breaker may need to trip and reset several times over its lifespan.

  • Multiple Electrode Breaking:Many LV circuit breakers can break multiple electrodes simultaneously. In complex electrical setups, such as three - phase power systems, this ability allows for the quick and effective isolation of all live conductors during a fault. This helps in preventing the spread of electrical faults and reduces the risk of damage to connected equipment.

  • High Breaking Capacity:Some models possess high breaking capacities. This is especially important in industrial and commercial applications where large short - circuit currents can occur. For instance, in a manufacturing plant with high - power machinery, a short - circuit could generate a substantial amount of current. A breaker with a high breaking capacity can safely interrupt this large current, protecting the entire electrical infrastructure.

Main Parameters

Dimensions

Weight

17 kg

Height

550 mm

Width

370 mm

Length

400 mm

Standards

Standards

HN 63-S-11

Electrical values

Rated Voltage (Ur)

0.44 kV

Rated current

165 A

Rated short-circuit breaking capacity

4 kA

Rated short-circuit making current

6.8 kA

Rated short-time withstand current (1s)

4 kA/s


10 kV

Lightning impulse withstand level of voltage (1.2/50)

20 kV

Features

Degree of protection

IP31

Output number

1

Conductor size

25 - 70mm²

Temperatures

Operating temperature

-25 ... 50 °C

Storage temperature

-25 ... 70 °C

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!