• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Nitrogen Insulated Switchgear

  • Nitrogen Insulated Switchgear
  • Nitrogen Insulated Switchgear
  • Nitrogen Insulated Switchgear
  • Nitrogen Insulated Switchgear
  • Nitrogen Insulated Switchgear

Key attributes

Brand Rw Energy
Series RGIS,DFW,XGN15
Description

Nitrogen Insulated Switchgear

Nitrogen gas insulation for medium-voltage switchgear — a clean, non-fluorinated alternative to SF6.

Product introduction

Nitrogen insulated switchgear is a medium-voltage metal-enclosed switchgear whose high-voltage compartment is insulated with nitrogen gas instead of sulfur hexafluoride. Nitrogen is a naturally abundant, inert gas with no global warming potential, which makes it an attractive insulation medium where an SF6-free, non-fluorinated solution is required.

Rockwell Energy manufactures nitrogen insulated switchgear for secondary distribution and industrial incomers. The switchgear uses sealed vacuum circuit breakers for current interruption, while nitrogen provides phase-to-earth and phase-to-phase insulation inside the gas-tight compartment. This combination delivers the same IEC 62271 performance class as conventional SF6 switchgear, but with no greenhouse gas in the equipment and no F-gas compliance burden at end of life.

Key features

The switchgear is built around a fully sealed, metal-enclosed tank that holds nitrogen at a controlled pressure. Live parts are isolated behind the gas envelope, giving compact dimensions suitable for kiosks, basements and industrial substations. The sealed vacuum breaker handles load, fault and transformer inrush currents, while an integrated pressure and position monitoring function reports the condition of the unit. An optional remote and distribution-automation interface is available for modern network control.

Because nitrogen has no greenhouse gas properties, the switchgear involves no leakage reporting, no fluorinated-gas inventory and no gas-recovery contractor at decommissioning. The steel enclosure and copper busbar are recyclable as standard materials. This makes nitrogen insulated switchgear a practical, low-lifecycle-cost choice for utilities and industrial users committed to decarbonizing their networks.

Typical specifications

Rated voltage 12kV / 24kV
Rated frequency 50 / 60 Hz
Insulation medium Nitrogen gas (non-fluorinated, zero GWP)
Breaking device Sealed vacuum circuit breaker
Rated normal current 630A / 1250A
Rated short-time withstand 20kA / 3s
Enclosure Metal-enclosed, gas-tight, recyclable
Standard IEC 62271-1, IEC 62271-200

Representative values are shown above. The certified datasheet for a specific project is prepared on request.

Nitrogen Insulated Switchgear

Applications

Nitrogen insulated switchgear is suited to urban and rural distribution networks, industrial plants, commercial buildings and renewable-energy substations where the project specification requires SF6-free, non-fluorinated equipment. It is also a direct replacement option where aging SF6 switchgear is being retired and the network owner wants to remove greenhouse gases from the system.

Documentation Resource Library Nitrogen Insulated Switchgear

Restricted
Partial Discharge Online Monitoring System for Ring Main Units Partial Discharge Online Monitoring System for Ring Main Units
Catalogue
English
PDF

Certifcations Nitrogen Insulated Switchgear

Frequently asked questions

Nitrogen provides phase-to-earth and phase-to-phase insulation inside a gas-tight sealed compartment, while a sealed vacuum circuit breaker handles current interruption.

Yes. The high-voltage compartment is insulated with nitrogen gas, which is a naturally abundant inert gas with no global warming potential. There is no SF6 or any fluorinated gas in the equipment.

Yes. It is built and type-tested to the same IEC 62271 performance class as conventional SF6 switchgear, with sealed vacuum interruption and gas-tight construction.

Nitrogen has zero global warming potential, so there is no leakage reporting, no fluorinated-gas inventory and no gas-recovery cost at end of life. The steel enclosure and copper busbar are recyclable.

For more detail on configuration, ratings or a quotation for a specific project, please contact Rockwell Energy.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: 100 Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Low Voltage Electrical Components/Renewable Energy and EV Charging/Electrical Testing and Metering/Lighting and Monitoring Equipment/Power Generation and Backup Systems/Power and Distribution Transformers/Instrument Transformers and Sensors/Transformer and Switchgear Parts/Construction Equipment and Tools/Electrical Manufacturing and Factory Automation/Lightning Protection and Electrical Insulation/Electrical Safety Equipment/Substations and E-Houses/Power Electronic Equipment/Electrical Panel and Controlgear/Power Quality Equipment
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register