Model
LDS135-500/5
Basic info
Brand Wone Store
Model NO. LDS135 Current Transformer
Rated frequency 50/60Hz
Power frequency withstand voltage 3kV
Rated current ratio 500/5
Series LDS
Product Detail

Product Overview

 Double cable Cores Type CT.LDS135 adopts newly high permeability core with high measuring accuracy.Secondary winding fully enclosed vacuum casting in antiflaming plastic shell. It easily installed by making the primary cable through the whole,applied to electrical system cable with highest equipment voltage 0.72,functioning as the tool of current metering , signal collection, relay protection. The current transformer can be executed according to the standard IEC 61869-1:2007 and IEC 61869-2:2012. Or IEC60044-1

Key Features

  • Modular Combination Expansion Capability:Engineered with a modular architecture, the LDS235 supports parallel connection of multiple units to meet ultra-high current measurement requirements. Users can flexibly scale the number of transformers based on actual load current, expanding the transformation ratio beyond 5000/5A while maintaining consistent measurement accuracy.
  • Dynamic Range Expansion Technology:Leveraging advanced magnetic circuit optimization and signal processing algorithms, the LDS135 achieves an industry-leading dynamic response ratio of 1:300. It delivers exceptional linearity from 0.1% of rated current under light loads to 30kA short-circuit fault conditions, ensuring reliable full-spectrum monitoring for power systems.
  • IoT-Integrated Design:Equipped with built-in IoT modules supporting NB-IoT and 4G protocols, the LDS135 seamlessly integrates with smart grid management platforms. Cloud-based remote configuration, real-time data monitoring, and analytics enable maintenance teams to access device status anytime, anywhere, streamlining intelligent and centralized power asset management.
  • Flexible Anti-Shock Structure:Featuring an innovative flexible buffer design with elastic support materials and seismic damping structures, the LDS135 withstands mechanical shocks up to 10G and severe vibrations. Ideal for applications with high vibration requirements such as rail transit systems and offshore wind platforms.

Technical Data

  • Rated secondary current:5A
  • Power frequency withstand voltage:3kV
  • Rated frequency:  50/60Hz
  • Installation site:  Indoor
  • Technical standard:   IEC 60044-1 (IEC 61869-1&2)

Specification

Outline

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!