• LDZC55 Current Transformer
LDZC55 Current Transformer
discuss personally
Model
LDZC55-100/5
Basic info
Brand Wone Store
Model NO. LDZC55 Current Transformer
Rated frequency 50/60Hz
Rated insulation voltage 10kV
Rated current ratio 100/5
Series LDZC
Product Detail

Product Overview

Single Cable Cores Type CT.LDC55 adopts newly high permeability core with high measuring accuracy.Secondary winding fully enclosed vacuum casting in antiflaming plastic shell. It easily installed by making the primary cable through the whole, applied to electrical system cable with highest equipment voltage 0.72KV, functioning as the tool of current metering , signal collection, relay protection. The current transformer can be executed according to the standard IEC 61869-1:2007 and IEC 61869-2:2012. Or IEC60044-1

Key Features

  • Intelligent Self-Calibration & Fault Diagnosis:Equipped with high-precision ADC and digital signal processing units, it real-time compares measured values with theoretical ones, automatically compensating errors caused by temperature, aging, etc., achieving calibration accuracy of ±0.05%. Through machine learning algorithms analyzing historical data, it predicts potential faults (insulation aging, winding short circuits, etc.) 72 hours in advance, and uploads early warnings to cloud management platforms via Modbus or MQTT protocols.
  • Modular Plug-and-Play Design:Adopting standardized interfaces and rail-mounted structures, it supports hot-swappable replacement without power outages. Functional modules (measurement, communication, power units) are independently packaged for flexible configuration. For example, adding an optical fiber module extends transmission distance beyond 20km to meet long-distance monitoring needs.
  • Extreme Environment Adaptability:Housing made of 316L stainless steel with double epoxy vacuum casting, reaching IP68 protection. Withstands -55℃~+125℃, resists salt spray >2000h and UV aging >5000h. ATEX/IECEx certified for explosive gas (Zone 1/2) and dust (Zone 21/22) environments, suitable for high-risk sites like petrochemical plants and coal mines.
  • Low Power Consumption & Energy Harvesting:Using low-power CMOS chip design, total power consumption <0.5W, 60% lower than traditional products. Built-in energy harvesting modules extract power from primary current to supply secondary circuits, outputting 5mA/5V DC at rated current for self-power supply, reducing external power dependency and O&M costs.

Technical Data

  • Rated insulation level: 0.72/3/10kV
  • Rated primary current: up to 1500A
  • Rated secondary current: 5A or 1A
  • Installation Altitude : 2000m

Specification

Outline

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!