• KWJC - 1500 Series High - Current Test Bench
KWJC - 1500 Series High - Current Test Bench
discuss personally
Model
KWJC - 1500
Basic info
Brand Wone Store
Model NO. KWJC - 1500 Series High - Current Test Bench
Rated voltage 220V
Rated capacity 5kVA
Series KWJC - 1500 Series
Product Detail

Overview

  • The KWJC - 1500 High - Current Test Bench is a new - type verification bench designed and developed by our company in accordance with the GB14048 《Low - voltage Switchgear and Control gear》 standard, the technical standards of relevant products, and users' special requirements.

  • This verification bench is composed of new - type components such as a voltage regulator, a current booster, a high - precision ammeter, a voltmeter, an AC contactor, buttons, and indicator lights. It can be used by production manufacturers or relevant quality inspection departments to conduct over - current and temperature rise tests on switches for safety assurance.

Parameters

Project

Parameters

Power input

Rated voltage

AC 220V±10% 50Hz

Power Input

2-phase 3-wire

rated output

Rated capacity

5kVA

Output current value

0~1500A

Error

≤1%

waveform distortion

≤1%

Instrument Accuracy

Ammeter accuracy

Level of 1

Voltmeter accuracy

Level of 1

Operating temperature

-10℃-45℃

Environmental humidity

20%~80%RH

 

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Automatic Reclosing Scheme in Transmission Systems
Automatic Reclosing Scheme in Transmission Systems
Automatic Reclosing Scheme for Transmission SystemsThe automatic reclosing system is a series-connected network designed to reduce operating costs and enhance network reliability. Extra-high voltage (EHV) transmission lines are used to transmit large amounts of power, on the order of thousands of megawatts (MW), and therefore should not be interrupted at all costs. Although faults on these overhead lines are common, the power transmitted through them should not be interrupted for long periods du
Encyclopedia
08/07/2025
Transformer Bushing Operating Principle
Transformer Bushing Operating Principle
In electrical power systems, a bushing is an insulating device that allows an electrical conductor to pass safely through a grounded conductive barrier, as in the case of transformers or circuit breakers. All transformer windings are connected to high-voltage lines, so special attention must be paid to the terminal connections to prevent flashover between the high-voltage terminals and the transformer body. In low-voltage distribution transformers, cable connections are made within a terminal bo
Edwiin
08/07/2025
Working Principle and Introduction of Rectifier Transformers
Working Principle and Introduction of Rectifier Transformers
Working Principle of Rectifier TransformersThe working principle of a rectifier transformer is the same as that of a conventional transformer. A transformer is a device that converts AC voltage based on the principle of electromagnetic induction. Typically, a transformer consists of two electrically isolated windings—the primary and secondary—wound around a common iron core. When the primary winding is connected to an AC power source, the alternating current generates a magnetomotive
Ron
08/07/2025
Common Faults and Diagnostic Technologies of Oil-immersed Distribution Transformers
Common Faults and Diagnostic Technologies of Oil-immersed Distribution Transformers
1.Common Faults and Diagnostic Measures1.1 Transformer Oil Leakage1.1.1 Oil Leakage from Tank Weld SeamsFor oil leakage at flat joints, direct welding is applicable. For leakage at corners or joints reinforced with stiffeners, the exact leakage point is often difficult to locate, and re-leakage may occur after welding due to internal stress. For such cases, repair welding with an added iron plate is recommended: for two-surface joints, the iron plate can be cut into a spindle shape for welding;
Vziman
08/07/2025
Why Should a Transformer Core be Grounded?
Why Should a Transformer Core be Grounded?
During transformer operation, the core and the metallic structures and components that secure the core and windings are exposed to a strong electric field, inducing a high potential relative to ground. If the core is left ungrounded, a potential difference can develop between the core and grounded parts such as clamps and the tank, leading to intermittent discharges. Additionally, the magnetic field surrounding the windings induces varying electromotive forces (EMF) in different metallic compone
Encyclopedia
08/07/2025
Why do resistors typically have values such as 4.7kΩ or 5.1kΩ instead of round numbers like 5kΩ?
Why do resistors typically have values such as 4.7kΩ or 5.1kΩ instead of round numbers like 5kΩ?
Many beginners in circuit design may find standard resistor values puzzling. Why are common values like 4.7 kΩ or 5.1 kΩ instead of round numbers such as 5 kΩ?The reason lies in the use of an exponential distribution system for resistor values, standardized by the International Electrotechnical Commission (IEC). This system defines a series of preferred values, including the E3, E6, E12, E24, E48, E96, and E192 series.For example:The E6 series uses a ratio of approximately 10^(
Rockwell
08/07/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!