• KW-10A DC Resistance measurement
KW-10A DC Resistance measurement
discuss personally
Model
KW-10A
Basic info
Brand Wone Store
Model NO. KW-10A DC Resistance measurement
Rated voltage 220V
Series KW-10A
Product Detail

Overview

  • The DC resistance measurement of windings is one of the routine tests for transformers. Its main purpose is to check whether the connection or mechanical characteristics between windings, between windings and leads are good, and whether the resistances between phases of windings are balanced, etc., so as to ensure the safe operation of transformers.

  • The series of transformer DC resistance testers developed and produced by our company adopt a 32 - bit ARM core as the processing core to control the whole machine, and automatically complete functions such as self - calibration, steady - current judgment, data processing, and resistance value display. They can measure the DC resistance of various types of transformers and mutual inductors. The instrument can directly work using the internal battery, which greatly facilitates the use of field workers.

Parameters

Project

Parameters

Error

≤0.2%

Resolution

0.1μΩ

Data storage

2000

Power supply

12V Lithium battery

Changer rated

AC 180V~260V 50/60Hz

Standby power consumption

≤1.8W

Operating temperature

-10~40℃

Operating humidity

≤80RH

Weight

3kg

 

Current-measurement range comparison table

Current

measurement range

Current

measurement range

10A

0.5mΩ~600mΩ

0.2A

3Ω~30Ω

5A

1mΩ~1.2Ω

50mA

20Ω~120Ω

3A

5mΩ~2Ω

20mA

50Ω~300Ω

1A

10mΩ~6Ω

10mA

100&Ω~600Ω

0.5A

1Ω~12Ω

2mA

500Ω~3000Ω

 

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a