• JDZXW-36W2 Outdoor Voltage Transformer
JDZXW-36W2 Outdoor Voltage Transformer
discuss personally
Model
JDZXW-36W2
Basic info
Brand Wone Store
Model NO. JDZXW-36W2 Outdoor Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 35/√3kV
Secondary voltage 110/√3V
Series JDZXW
Product Detail

Product Overview

JDZXW-36W2 voltage transformer adopts outdoor epoxy resin material casting and single pole insulated voltage transformer, is widely used for measuring current, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest voltage for equipment 36 kV (Up to ~40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Outdoor Protection Design:Adopts silicone rubber composite insulation jacket with IP67 protection rating, resisting salt fog, dust, UV radiation, and other harsh environmental factors to ensure long-term outdoor operational stability. The external insulation creepage distance ≥31mm/kV, suitable for Class Ⅲ and above pollution areas, effectively reducing the risk of fouling flashover accidents.

  • High-precision Voltage Conversion:Utilizes high-quality silicon steel core and optimized electromagnetic design, with voltage ratio error controlled within Class 0.2 and phase difference ≤10', providing precise voltage signals for metering devices and relay protection systems to meet high-precision measurement requirements of power systems.

  • Wide Temperature Adaptability:Operates within the temperature range of -40℃~+70℃, using low-temperature tough epoxy resin and high-temperature resistant insulation materials to ensure stable performance in extreme temperature environments and avoid insulation aging caused by temperature changes.

  • High Insulation Reliability:The insulation system passes 36kV/75kV/170kV withstand voltage tests with partial discharge ≤5pC, and is equipped with built-in overvoltage protection devices to effectively prevent damage from switching overvoltage and lightning impulse.

Main technical parameter

  • Rated primary voltage:30/√3kV or 33/√3kV or 34.5/√3kV or 35/√3kV etc

  • Rated secondary voltage:100/√3V or 110/√3V or 115/√3V or 120/√3V

  • Rated voltage of residual voltage windings:100/ 3V or 110/ 3V or 115/ 3V or 120/ 3V

  • Technical standard accords with IEC 60044-2.2003 or IEEE etc

Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download