• JDZW3-36 outdoor epoxy resin casting Voltage transformer
JDZW3-36 outdoor epoxy resin casting Voltage transformer
discuss personally
Model
JDZW3-36
Basic info
Brand Wone Store
Model NO. JDZW3-36 outdoor epoxy resin casting Voltage transformer
Rated frequency 50/60Hz
Primary voltage 35kV
Secondary voltage 110V
Series JDZW
Product Detail

Product Overview

JDZW3-36 voltage transformer, outdoor epoxy resin casting and double pole insulated VT, is widely used for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50Hz or 60Hz and insulation voltage 36 kV (Up to 40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Excellent Outdoor Insulation Protection:JDZW3-36 uses high-quality epoxy resin as the main insulation material, with a silicone rubber coating on the outer layer. The internal traditional epoxy resin casting process ensures the transformer's insulation and electrical performance. Silicone rubber features excellent arc resistance, hydrophobicity, and climatic adaptability, enabling the equipment to operate normally in high-altitude, high-salt fog, rainy, and strong UV environments. Even if system faults cause explosions, the external silicone rubber structure restrains internal resin, reducing splashing damage to surrounding personnel, livestock, or equipment.

  • High Precision & Low Partial Discharge:The vacuum casting process achieves uniform electric field distribution with low partial discharge, enabling precise voltage measurement. Voltage ratio error is controlled within a minimal range, meeting high-precision metering and protection needs to provide reliable voltage data for 36kV and below power systems.

  • Fully Enclosed & Sealed Design:Primary and secondary terminals are completely sealed to prevent dust, moisture, and impurities from invading, avoiding electrical performance degradation caused by external factors. This extends service life and ensures stable operation in complex outdoor environments.

  • Strong Anti-Fouling Capability:The external insulation has high dry arc and large creepage distance, with creepage distance meeting or exceeding relevant standards—especially suitable for high-pollution areas. The surface undergoes special treatment to further enhance anti-fouling performance and reduce flashover risks.

  • Durable Metal Components:All metal components are hot-dip galvanized to enhance corrosion resistance, withstanding long-term outdoor exposure to wind, rain, and sunlight—ensuring reliable long-term service in outdoor environments.

Main technical parameter

  • Rated primary voltage:30 kV or 33 kV or 35 kV etc.

  • Rated secondary voltage:100 V or 110 V

  • Rated power-frequency withstand voltage: 70kV

  • Rated lightning impulse withstand voltage: 170kV

  • Technical standard accords with IEC 60044-2.2003.

  • Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!