• JZW-72.5 Outdoor Voltage Transformer
JZW-72.5 Outdoor Voltage Transformer
discuss personally
Model
JZW-72.5
Basic info
Brand Wone Store
Model NO. JZW-72.5 Outdoor Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 66/√3kV
Secondary voltage 110/√3V
Series JZW
Product Detail

Product Overview

JZW-72.5 voltage transformer, epoxy resin casting and outdoor installation, is widely used for measuring current, electric energy and protective relaying in the power system with the frequency of 50Hz or 60 Hz and rated voltage of 66kV or 69kV.

The product can be operated on many circumstances such as the areas of altiplano, tropical area, chillness, coastland and dirtiness etc.

Key Features

  • High Voltage Rating Adaptability:With a rated voltage of 72.5kV, it is specially designed for medium-to-high voltage outdoor substations, enabling precise system voltage measurement to meet metering, protection, and monitoring needs of grids up to 72.5kV.
  • Fully Sealed Weather-resistant Structure:Featuring silicone rubber composite insulators and a stainless steel housing, it achieves IP67 protection rating, offering excellent moisture, dust, and salt fog resistance. It withstands strong UV radiation and extreme temperatures from -40℃ to +70℃, adapting to harsh outdoor environments like deserts and coastal areas.
  • Anti-fouling Flashover & Explosion-proof Design:With external insulation creepage distance ≥35mm/kV, anti-fouling flashover skirts, and a hydrophobic coating, it suits Class Ⅳ pollution areas. Certified to IEC 60076-11 explosion-proof standards, it integrates a pressure relief device to ensure no explosion risk during faults.
  • High-precision Voltage Transformation:Utilizing low-loss silicon steel sheets and foil winding technology, it maintains voltage ratio error ≤0.2% and phase difference ≤10', meeting 0.2-class metering accuracy requirements to provide precise voltage data for power grids.
  • Low Power Consumption & Long Lifespan:With no-load loss ≤60VA and load loss ≤150VA, it saves 15% energy compared to traditional transformers. The epoxy resin casting insulation system ensures a 40-year service life, reducing replacement frequency and O&M costs.

Main technical parameter

  • Highest voltage for equipment: 72.5kV
  • Rated primary voltage: 66/√3kV or 69/√3kV etc
  • Limiting output :2000VA
  • Rated power-frequency withstand voltage: 140kV
  • Rated lightning impulse withstand voltage: 325kV or 350kV
  • Rated insulation level: 72.5/140/325kV or  72.5/140/350 kV
  • Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers or IEEE STD C57.13-2008

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!