• Ceramic Load Drop Out Fuse
  • Ceramic Load Drop Out Fuse
Ceramic Load Drop Out Fuse
discuss personally
Model
RW3-38kV-100/200A
RW3-24kV-100/200A
RW3-15kV-100/200A
RW3-11kV-100/200A
Basic info
Brand Switchgear parts
Model NO. Ceramic Load Drop Out Fuse
Rated voltage 38kV
Rated normal current 100/200A
lightning impulse withstand voltage 170kV
Series RW3
Product Detail

LOADBREAK Cutout

This LOADBREAK fuse cutout is available for application on 10kv to 38kv distribution system. The addition of the arc chute provides loadbreak capability for fuse cutouts. Also expands the flflexibility of the protective devices.The loadbreak fuse cutout provides short circuit protection to overhead lines with the added feature of a loadbreaking function. Maximum rating current 100-200A

Product features

High performance of weather aging resistance 

For porelain insulator, the porcelain body connects with hardware fitting by cement pouring, we use the (por-rok)ANCHORING cement manufactured by CGM INC from USA. This kind of cement has rapid solidification, high mechanical strength, low expansion coefficient and superior weather resistance.

For polymer insulator, the hardware fitting crimped onto fiberglass rod, material of housing and sheds manufacture of high-temperature Vulcanized Silicone Rubber, and the insulator moulded by one piece injection molding. It has good sealing performance and good performance of tracking and erosion resistance.

All ferrous parts processed by hot dip galvanized, its zinc coating more than 86u, it has good corrosion resistance.

Design feature of single vent

Our fuse cutout adopts the design feature of single vent, exhaust downwards and outwards when fuse cutout interrput. Prevent the intrusion of rainwater, avoid damage to the upper line by free gas, and this design can improve the interrput capacity.

Excellent conductivity

All copper casting part adopts bronze/brass, it has excellent mechanical strength and excellent conductivity.

All contact parts be silver-plated, it adopts convex design on the contact surface, this design can reduce the contact resistance and ensure excellent conductivity.

The high-strength memory cooper alloy sheets can ensure contact with lower contact smoothly and without any affecting when fuse drop out.

It adopts Arc-shortening copper rod to improve the interrput capacity when short circuit fault.

Reliable load breaking capacity

For Loadbreak type fuse cutout, its arc chamber made of special reinforced nylon material. It has good mechanical strength, anti-aging and flame retardant. suitable for use the area like high ultraviolet area, high altitude area, coastal area, etc.

Relevant international executive standards

All fuse cutouts we manufacture and test according to the latest international standard IEC 60282-2:2008 & IEEE Std C37.41-2008 & IEEE Std C37.42-2009.

WARM TIPS

When order,please indicate the detailed information as below listed:

1) Rated voltage and rated current .

2) Minimum creepage distance.

3) The material of insulator.

4) Please indicate whether arc-shortening rod should be fitted with fuse cutout.

5) Please indicate the type of mounting bracket.

Rated voltage(KV)

Rated current(A)

Rated interrupting current (KA)

Lightning impulse withstand voltage to ground (BIL KV)

Minimum power frequency withstand dry voltage to ground (KV)

Minimum creepage distance(mm)

11 - 15

100/200

12

110

42

220

11 - 15

100/200

12

125

50

320

24 - 27

100/200

12

150

65

470

33 - 38

100/200

8

170

70

660

33 - 38

100/200

8

170

70

720

33 - 38

100/200

8

170

70

900

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a 50Hz-Designed Power Transformer Operate on 60Hz Grid?If a power transformer is designed and built for 50Hz, can it run on a 60Hz grid? If so, how do its key performance parameters change?Key Parameter ChangesShort-Circuit Impedance:For a given transformer (same voltage and capacity), short-circuit impedance is proportional to frequency. Thus, a 50Hz-designed unit operating at 60Hz sees a 20% increase—higher frequency intensifies alternating leakage field opposition to current.No-Load
Vziman
07/29/2025
What are the common faults of overhead cables?
What are the common faults of overhead cables?
Overhead cables, due to their exposure to external environments, are subject to various influences that can lead to different types of faults. Below are some common types of faults in overhead cables and their causes:1. Mechanical DamageCaused by external forces such as falling trees, vehicle collisions, or construction accidents.Prolonged vibrations or swinging can also cause material fatigue in cables.2. Weather-Related FaultsLightning Strikes: Direct hits or nearby lightning strikes can cause
Felix Spark
07/29/2025
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
A core challenge in online cable eccentricity measurement is the cable’s high - speed motion. This requires non - contact measurement equipment that can handle cable jitter. X - ray cable eccentricimeters, based on optical transmission imaging, measure multi - layer contour dimensions to calculate the geometric center of conductors relative to insulation eccentricity. However, they have drawbacks: slow measurement speed (only a few times per second), increased errors from cable jitter, and
Oliver Watts
07/29/2025
An Intelligent Device for Insulation Restoration of Low-Voltage Overhead Cables
An Intelligent Device for Insulation Restoration of Low-Voltage Overhead Cables
1. Current Situation and ProblemsLow - voltage overhead cables often suffer insulation damage. Urbanization and infrastructure construction expose them to complex environments (construction, severe weather like strong winds/rains causing scratches or impacts, animal damage), easily breaking insulation layers. Long - term operation also degrades insulation due to aging, corrosion, and prolonged sunlight—e.g., cables in old communities age and crack, raising failure risks.Existing restoratio
Dyson
07/29/2025
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station
1 Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station1.1 Data CollectionBefore constructing the BIM model for cable laying, it is necessary to deeply master the detailed parameters of the involved equipment specifications, materials used in construction, and site conditions, aiming to improve the accuracy of model construction. To ensure that the BIM model can accurately reflect the actual situation of the construction site, the core lies in accurately colle
Echo
07/29/2025
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
Cable Detection and Analysis of Integrated Wiring System in Intelligent Buildings
The integrated wiring system of intelligent buildings, as the core carrier of information transmission, functions like a "nervous system." It connects signals such as voice, data, and images, enabling device interconnection and efficient information transmission. Cable detection is a key link to ensure system performance and information security, focusing on index detection, problem troubleshooting, and response measures.1. Core Cable Detection Indicators1.1 Appearance and Identification Verific
Oliver Watts
07/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!