• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Pangkalahatang Pagsusuri ng Transformer na Naka-Integrate

  • Integrated Transformer Comprehensive Test Device

Mga Pangunahing Katangian

Brand Switchgear parts
Numero ng Modelo Pangkalahatang Pagsusuri ng Transformer na Naka-Integrate
Rated Current 5000A
Serye HB28BZ

Mga Deskripsyon ng Produkto mula sa Supplier

Pagsasalarawan

Mga Katangian

Ang sistemang experimental ay maaaring detektohin ang mga distribution transformers, American style box type substations, at European style box type substations.
Isang wiring lang ang kailangan upang matapos ang mga proyektong pagsusuri tulad ng direct resistance, transformation ratio, on load switch, no-load test, load test, induction withstand voltage, temperature rise test, at iba pa. Ito rin ay maaaring mag-automatikong gawin ang mga pagsusuri tulad ng insulation, dielectric loss, power frequency withstand voltage, zero sequence impedance, at iba pa.
Ang sistema ng pagsusuri ay mayroong 20kV high-voltage switching device at 5000A high current fast short-circuit switching device, na maaaring automatikal na matapos ang mga pagsusuri ng no-load, load, zero sequence impedance, at temperature rise. Ang high-voltage output device ay maaaring palawigin para sa madaling pagkonekta ng sample na isusubok.
Ang sistemang experimental ay mayroong espesyal na error testing device, na maaaring mag-analisa nang kwantitatibo ng mga error sa pagsusuri at makakuha ng tama at wastong resulta ng pagsusuri.
Ang sistemang experimental ay may LED Chinese character display protection screen, na maaaring ipakita ang kalagayan ng sistema sa anumang oras upang mapanatili ang kaligtasan ng mga tauhan na gumagamit nito.
Ang sistemang experimental ay may kakayahan sa teknolohiyang impormasyon at nagtatapos ng data exchange sa pamamagitan ng koneksyon ng grid at cloud platform management system.

Class C test equipment Model Technical parameters
DC resistance testing unit HB5851 Automatic current testing: 5mA, 40mA, 200mA, 1A,5A,10A
dielectric loss testing unit HB5805 Output voltage: 100V,250V,500V,1000V,2500V,5000V Short-circuit current: 5mA
voltage ratio group testing unit HB7601 Range: Capacitance: 3pF~60000pF, Dielectric loss: 0~10%, Ratio: 1-3000 Measurement accuracy: Capacitance: ±(1%× reading + 1pF), Dielectric loss: ±(1%× reading + 0.0004), Ratio: Class 0.2
Impedance test unit HB6605 Range: Capacitance: 3pF~60000pF, Dielectric loss: 0~10%, Ratio: 1-3000 Measurement accuracy: Capacitance: ±(1%× reading + 1pF), Dielectric loss: ±(1%× reading + 0.0004), Ratio: Class 0.2
test unit power analyzer HB2000 Measurement Range: 0.9 to 10,000; Measurement Accuracy: ±0.2%
short-circuit power tester HB2813 Voltage Measurement Ranges: 50V,100V,250V,500V (phase voltage); Voltage Measurement Error: ±(0.05% reading + 0.05% range); Current Measurement Ranges: 1A,5A,10A,20A,50A,100A; Current Measurement Error: ±(0.05% reading + 0.05% range)
three-phase sinusoidal frequency conversion test power supply HB28YZ Voltage Measurement Error: ±(0.2% reading + 0.2% range); Current Measurement Error: ±(0.2% reading + 0.2% range); Power Measurement Error: ±(0.5% reading + 0.5% range)
test transformer YDQ-10/50 Rated Capacity: 30kVA; Output Voltage: 600V,850V; Output Frequency: 50-200 Hz
voltage divider FC-50 Rated Capacity: 10kVA; Output Voltage: 50kV
high-voltage peak meter HB2601 Rated Voltage: 50kV with 1.5% measurement accuracy
compensation capacitor bank HB2819W Measurement Range: 0-50kV with 1% precision
electric high-current switch HB29GK3 Rated Voltage: 690V; Compensation Capacity: 260kvar
electric disconnect switch HB29GK2 Rated Current: 5000A (3-phase)
ground conduction resistance tester HB5878 Rated Voltage: 10kV; Rated Current: 200A (10A auxiliary contacts)
single-phase current source HB2819Z-1 Automatic test currents: 200mA, 1A,5A,10A.10A:0.5mΩ~800mΩ (5A): 2mΩ~20,1A:5mΩ~10Ω
control system   Features automatic testing switching, measurement range adjustment, low-voltage short-circuit voltage measurement, compensation control, data communication, and safety protection systems.
computer-based system and software HB2819GL-1 Test system login, test personnel management, test sample identification, test item setting, test data setting, project switching, status reading, data uploading, environmental parameter reading and judgment.
equipment structure and accessories HB2819ZN-1 Equipment carrying, high voltage electric switch switching, low voltage electric switch switching, outgoing car drive, high voltage electrical connection, sealing structure.

 

FAQ
Q: Mayroong mga espesyal na pangangailangan para sa pag-install at operasyon?
A:
Nangangahang ang operasyon ng mga propesyonal na inhenyero elektrikal, na may pangunahing mga pangangailangan na nakaayon sa mga internasyonal na espesipikasyon para sa operasyon ng elektrisidad:
  1. Paghahanda bago ang operasyon: Siguruhin na ang transformer na sususpinilin ay lubhang walang kuryente, na-discharge, at na-ground; linisin ang mga terminal ng test ng transformer upang alisin ang mga oxide layer, dust, at oil stains upang maiwasan ang pagkakaapekto ng contact resistance sa resulta ng test;
  2. Espesipikasyon ng pagkakakonekta: Gumamit ng high-quality na tansong kable na may angkop na cross-sectional area (≥4mm² para sa small current tests, ≥16mm² para sa large current tests); sumunod nang mahigpit sa wiring diagram upang ikonekta, na iwasan ang reverse connection ng high-voltage/low-voltage sides at poor grounding;
  3. Mga hakbang sa operasyon: Piliin ang mga item ng test sa touchscreen → I-set ang mga parameter ng transformer (capacity, rated voltage) → Simulan ang awtomatikong testing → Monitorin ang progreso ng test sa tunay na oras → Pagkatapos, i-export ang PDF/Excel test reports;
  4. Mga pagsasadya sa kaligtasan: Sa panahon ng withstand voltage testing, itayo ang mga safety fences at warning signs sa paligid ng transformer at device; hindi pinapayagan ang anumang tao na lumapit sa high-voltage test area; agad na itigil ang test kung may abnormal na spark, ingay, o alarm.
Q: Ano ang mga pangunahing punsiyon at prinsipyo ng paggana?
A:

 Ito ay isang mataas na naka-integrate, multi-functional na precision testing instrument na disenyo para sa comprehensive na electrical performance detection ng mga power transformers, distribution transformers, oil-immersed transformers, at dry-type transformers. Ang pangunahing function nito ay ang pag-integrate ng 8+ key test items sa isang device, na nagpapahintulot ng one-stop testing ng transformer winding DC resistance, turns ratio & connection group, no-load/load loss, insulation resistance, withstand voltage, OLTC dynamic performance, at optional winding deformation (FRA) test, nang walang repeated wiring.

Prinsipyong Paggamit: Konektahan ang device sa high-voltage side, low-voltage side, neutral point, at control circuit ng transformer nang isa lang. Ang embedded industrial computer ay nagkokontrol ng relay matrix upang awtomatikong mag-switch ng test circuits, lumilikha ng standard test signals (high voltage/large current), kumukolekta ng real-time data sa pamamagitan ng 16-bit high-speed ADC sampling module, nagproseso ng data gamit ang DSP digital signal processing technology, at kinokompara ito sa IEC 60076, IEEE C57, at GB 1094 standards upang lumikha ng compliant at traceable test report. Ito ay nag-integrate ng maraming test functions upang maiwasan ang problema ng pag-switch sa pagitan ng split instruments, na malaking nagpapabuti sa testing efficiency.

Alamin ang iyong supplier
Tindahan Online
Rate ng on-time delivery
Oras ng Pagsagot
100.0%
≤4h
Pangkalahatang Impormasyon ng Kompanya
Lugar ng Trabaho: 1000m² Kabuuang bilang ng mga empleyado: Pinakamataas na Taunang Export (US Dollar): 300000000
Lugar ng Trabaho: 1000m²
Kabuuang bilang ng mga empleyado:
Pinakamataas na Taunang Export (US Dollar): 300000000
Serbisyo
Uri ng Pagnenegosyo: Sales
Pangunahing Kategorya: Mga Aksesorya ng Pagsasakatawan/Pagsusuri ng mga aparato/Mataas na Voltaheng mga Aparato/Mga aparato sa mababang voltaje/Instrumentasyon/Mga Pagsasagawa ng Produksyon/Pangkalahatang Paggamit ng Enerhiya sa Pagproseso ng IEE-Business
Pamamahala ng Buhay
Mga serbisyo sa pangangalaga at pamamahala sa buong buhay para sa pagbili, paggamit, pagpapanatili, at售后 ng kagamitan, upang masiguro ang ligtas na operasyon ng mga kagamitang pangkuryente, tuluy-tuloy na kontrol, at maaliwalas na pagkonsumo ng kuryente.
Ang supplier ng kagamitan ay nakapasa sa sertipikasyon ng karapatang pumasok sa platform at teknikal na pagtatasa, tinitiyak ang pagtugon, propesyonalismo, at katiyakan mula pa sa pinagmulan.

Mga Produkto na May Kaugnayan

Kaalamayan na may Kaugnayan

  • Mga Aksidente sa Pangunahing Transformer at mga Isyu sa Pagsasanay ng Light Gas
    1. Tala ng Aksidente (Marso 19, 2019)Noong ika-16:13 ng Marso 19, 2019, inulat ng monitoring background ang isang light gas action ng No. 3 main transformer. Ayon sa Code for Operation of Power Transformers (DL/T572-2010), sinaunang tiningnan ng mga tauhan ng operation and maintenance (O&M) ang kondisyon ng No. 3 main transformer sa lugar.Konfirmasyon sa lugar: Inulat ng WBH non-electrical protection panel ng No. 3 main transformer ang isang Phase B light gas action ng katawan ng transformer
    02/05/2026
  • Mga Kamalian at Pamamaraan sa Paggamot ng Single-phase Grounding sa 10kV Distribution Lines
    Mga Katangian at mga Device na Paggamit sa Pagkakakilanlan ng Single-Phase Ground Fault1. Mga Katangian ng Single-Phase Ground FaultMga Signal ng Sentral na Alarm:Tumutunog ang bell ng babala, at nag-iilaw ang indicator lamp na may label na “Ground Fault sa [X] kV Bus Section [Y].” Sa mga sistema na may Petersen coil (arc suppression coil) na nakakonekta sa neutral point, nag-iilaw din ang indicator na “Petersen Coil Operated.”Mga Indikasyon ng Insulation Monitoring Voltmeter:Bumababa ang voltag
    01/30/2026
  • Pamamaraan ng pag-ground ng neutral point para sa 110kV~220kV power grid transformers
    Ang pagkakasunod-sunod ng mga paraan ng pag-ground ng neutral point sa mga transformer ng power grid na 110kV~220kV ay dapat tugunan ang mga pangangailangan ng insulation withstand ng mga neutral points ng mga transformer, at kailangang ito ring panatilihin ang zero-sequence impedance ng mga substation na hindi masyadong nagbabago, habang sinisigurado na ang zero-sequence comprehensive impedance sa anumang short-circuit point sa sistema ay hindi liliit ng tatlong beses ang positive-sequence comp
    01/29/2026
  • Bakit Gumagamit ng Bato Gravel Pebbles at Crushed Rock ang mga Substation?
    Bakit Gumagamit ng Bato, Gravel, Pebbles, at Crushed Rock ang mga Substation?Sa mga substation, ang mga kagamitan tulad ng power at distribution transformers, transmission lines, voltage transformers, current transformers, at disconnect switches ay nangangailangan ng pag-ground. Sa labas ng pag-ground, susuriin natin nang mas malalim kung bakit karaniwang ginagamit ang gravel at crushed stone sa mga substation. Bagama't tila ordinaryo lang sila, ang mga bato na ito ay gumaganap ng mahalagang pap
    01/29/2026
  • Bakit Kailangan I-ground ang Core ng Transformer sa Iisang Punto Lamang? Hindi ba Mas Handa ang Multi-Point Grounding?
    Bakit Kailangan I-ground ang Core ng Transformer?Sa panahon ng operasyon, ang core ng transformer, kasama ang mga metal na istraktura, bahagi, at komponente na naka-fix sa core at windings, ay lahat nasa malakas na elektrikong field. Sa impluwensya ng elektrikong field na ito, nakakakuha sila ng relatyibong mataas na potensyal sa paghahambing sa lupa. Kung hindi grounded ang core, magkakaroon ng potential difference sa pagitan ng core at ng mga grounded clamping istraktura at tank, na maaaring m
    01/29/2026
  • Pag-unawa sa Neutral Grounding ng Transformer
    I. Ano ang Neutral Point?Sa mga transformer at generator, ang neutral point ay isang tiyak na punto sa winding kung saan ang absolutong voltaje sa pagitan ng punto na ito at bawat panlabas na terminal ay pantay. Sa diagrama sa ibaba, ang puntoOay kumakatawan sa neutral point.II. Bakit Kailangan ng Pag-ground ang Neutral Point?Ang elektrikal na paraan ng koneksyon sa pagitan ng neutral point at lupa sa isang tatlong-phase AC power system ay tinatawag naneutral grounding method. Ang paraan ng pag-
    01/29/2026
Hindi pa rin nakakahanap ng tamang supplier Let verified suppliers find you Kumuha ng Kita Ngayon
Hindi pa rin nakakahanap ng tamang supplier Let verified suppliers find you
Kumuha ng Kita Ngayon
Inquiry
+86
I-click para i-upload ang file
I-download
Kumuha ng IEE-Business Application
Gamit ang app na IEE-Business upang makahanap ng kagamitan makuha ang mga solusyon makipag-ugnayan sa mga eksperto at sumama sa industriyal na pakikipagtulungan kahit kailan at saanman buong pagsuporta sa pag-unlad ng iyong mga proyekto at negosyo sa enerhiya