• Indoor AC high-voltage vacuum load break switch
Indoor AC high-voltage vacuum load break switch
discuss personally
Model
FZN25A-12/200
Basic info
Brand ROCKWILL
Model NO. Indoor AC high-voltage vacuum load break switch
Rated voltage 12kV
Rated normal current 200A
Rated frequency 50/60Hz
Series FZN
Product Detail

Product Overview

 Indoor AC high-voltage vacuum load switch (hereinafter referred to as load switch) is suitable for three-phase AC 50Hz, 12kV power supply network, as a break load current and close short-circuit current. The product can be equipped with manual and motor operating mechanisms, especially suitable for places with severe conditions, long maintenance cycles and frequent operation requirements.
Vacuum load switch-fuse combination with fuse (hereinafter referred to as combination appliance) FZRN25A-12(D)/T200-31.5 can break the short-circuit current for short-circuit protection. The product has a mechanism tripping, equipped with a fuse with an impactor, when passing the overload current or short-circuit current, the fuse is blown, and the impactor hits the tripping device to make the load switch automatically open to avoid phase loss operation.

Key Features

  • High - efficiency Arc Extinction and Breaking Capacity:Leveraging the high insulation strength and rapid arc - extinction characteristics of the vacuum interrupter, it can quickly extinguish the arc and reliably break load currents, overload currents, and even short - circuit currents under certain conditions. This significantly reduces the ablation of the contacts by the arc and extends the electrical service life of the equipment. For example, in a frequently operated power distribution system, it can stably perform circuit switching operations, reducing the probability of failures.
  • High Insulation Performance:The vacuum environment itself has extremely high insulation performance. Coupled with a reasonable insulation structure design, the indoor AC high - voltage vacuum load break switch can operate reliably in high - voltage environments, effectively preventing phase - to - phase and phase - to - ground short circuits and ensuring the safety and stability of the power system.
  • Fast Switching:Equipped with an advanced operating mechanism, it can achieve fast switching operations with short switching times. It can quickly isolate faulty circuits, reducing the impact of faults on the system. For instance, in the event of a short - circuit fault, it can rapidly cut off the circuit, limit the duration of the short - circuit current, and reduce the risk of equipment damage.

Technical Parameters

 Operating Environmental Conditions

  • Ambient Air Temperature: Maximum +40°C, Minimum -10°C
  • Altitude: Not exceeding 1000m
  • Relative Humidity: Daily average not greater than 95%, Monthly average not greater than 90%
  • Seismic Intensity: Less than Grade 8
  • Ambient Air Shall Be Free from Pollution by Corrosive, Flammable Gases, Water Vapor and Other Harmful Gases
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!