• IMB Series HV outdoor current transformers
IMB Series HV outdoor current transformers
discuss personally
Model
IMB-800
IMB-420
IMB-245
IMB-145
IMB-73
Basic info
Brand Rockwell
Model NO. IMB Series HV outdoor current transformers
Rated voltage 800kV
Series IMB Series
Product Detail

Overview

Main features
● The unique ‘filling’ composition of oil and quartz results in a compact design
● No oil change or filtration required as the expansion chamber / cooler is filled with Nitrogen (N2) / Metal bellows
● All external iron parts are MS painted for protection against detrimental effects of atmosphere and chemicals
● High seismic withstand capability in both vertical and horizontal directions
● Flexible design to meet special customer requirements such as low currents, high burden, creepage and high altitude
● All gaskets are below oil level ensuring positive oil sealing

Primary winding

The hairpin shaped conductor with graded insulation ensures uniform voltage distribution. The winding is insulated with special paper which has high mechanical and dielectric strength as well as low dielectric losses and good resistance to ageing.

Ratio selection is generally achieved through suitable secondary tapping in the secondary winding.

For ratios in multiples up to and including 1500 A (e.g. 1500-750, 1400-700, 1000-500-250, etc.) selection can also be achieved by a reconnectable primary winding. The primary winding is divided into equal parts, which can be connected in series or parallel by means of external links on the connection head.

The Short Time Current (STC) rating is as per series connection of primary winding (i.e. minimum cross section). With a parallel connection, the STC rating is therefore doubled.

The primary winding consists of a tube open at both ends allowing the oil to circulate. The heat losses are dissipated in the expansion chamber/cooler.

Tan Delta measuring terminal (D3/F terminal)

The outer shield of primary insulation is connected to a bushing in the secondary terminal box and earthed. This is designated as D3/F terminal.

This Tan Delta (D3/F) terminal must be earthed before the CT is charged.

Core

The Current Transformers can normally accommodate up to five cores. However more cores can also be provided on request. High-grade-silicon-steel CRGO is used for manufacture of cores. Stringent accuracy requirements of metering cores are achieved by using special cores made from nickel-iron alloy.

High grade enameled wires are used for winding secondary turns on the cores. They are evenly distributed across the periphery of the core, reducing leakage reactance to a minimum.

Tank & insulator

The lower portion of the CT consists of a aluminium or MS painted tank in which the cores are positioned around the straight limb primary winding. The upper portion of the transformer consists of high-grade brown glazed insulator made from porcelain or polymer. The gaskets are made of oil-proof material.

Technology paramete

 

Know your supplier
Rockwell
Wenzhou Rockwell Transformer Co., Ltd. It is a high - tech enterprise integrating R & D, production, sales, and service. It focuses on the manufacturing of power transformers and supporting equipment, and is committed to providing efficient, reliable, and energy - saving power transmission and distribution solutions for global customers. We can offer: •Distribution transformers and substations •Outdoor switchgears and breakers(recloser) •Switchgears and it’s components (GIS, RMU, VCB, SF6 CB) Market and Service: We always take customers as the orientation and provide customized services according to their requirements. Our products are exported to the Middle East, Africa, Northern Europe, South America, and many other countries and regions. Drive the future of electricity with technological innovation and become a leading global supplier of intelligent power equipment.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
60000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!