• HV510 series high-performance frequency converters
  • HV510 series high-performance frequency converters
  • HV510 series high-performance frequency converters
HV510 series high-performance frequency converters
discuss personally
Model
HV510/380V
Basic info
Brand RW Energy
Model NO. HV510 series high-performance frequency converters
Rated frequency 50/60Hz
Series HV
Product Detail

Overview

HV510 series frequency converter is a new generation of high-performance vector frequency converter of Hewang Electric, using a new high-performance open and closed loop vector control technology, supporting asynchronous motor and permanent magnet synchronous motor drive control; The high-quality, powerful performance and high-power density design enhance the advantages of ease of use, reliability, environmental adaptability, functional diversity, application flexibility in industrial applications, improve design standards and optimize installation space, etc., and upgrade the user experience in many aspects. It is widely used in metallurgy, lifting, petroleum, machine tools, plastics, metal products, papermaking, textile, printing and packaging and other automatic production equipment to drive.

Performance characteristics

Safe and reliable

  • Innovative independent air duct design

  • Efficient and accurate thermal simulation design

  • Rigorous temperature rise test and factory load aging

  • Automatic spraying process of conformal paint

  • Perfect fault protection function

High adaptability

  •  Wide grid adaptation design, -15%~+10%

  • Built-in C3 filter

  • EMC ground break design

  • Built-in brake unit design

  • Refined book-type design

Advanced control technology

  • V/F, open-loop vector, closed-loop vector control

  • Support drive asynchronous motor, permanent magnet synchronous motor

  • Support motor speed and torque mode control

  • Support two sets of motor parameter switching control

Excellent performance

  • Rich and comprehensive motor parameter self-identification ability

  • Perfect braking ability, support DC braking, energy consumption braking

  • Support various mainstream communication protocols: Profibus-DP, Profinet, etc.

  • Diversified expansion capabilities, I/O terminal cards, communication cards, etc

Featured app features

  • Output frequency up to 1500Hz

  •  Master-slave synchronous control function

  • Power failure restart function

  • Zero servo function

  • Swing frequency function

  • Encoder redundancy function

Autonomous and rapid commissioning

  • Background quick debugging software is available • Support frequency converter event recording and 12-channel oscilloscope recording

  • Support parameter editing, status monitoring, fault data and waveform download

Main parameters

project

Specifications and technical data

Input voltage

380V (-15%)~480V (+10%) three-phase

Input power frequency

50Hz/60Hz ±5%

Input voltage imbalance

≤3%

Output voltage

0V~input voltage

Output frequency

0Hz~1500Hz

Motor type

Asynchronous motor, permanent magnet synchronous motor

Control mode

V/F, OLVC (Open-Loop Vector Control), CLVC (Closed-Loop Vector Control)

speed regulation range

1:100 V/F; 1:200 OLVC; 1:1000 CLVC

Start torque

VF:100%(0.5Hz);OLVC:150%(0.25Hz);CLVC:200%(0Hz)

Torque accuracy

±5% (OLVC, 5Hz and above), ±3% (CLVC)

Torque pulsation

≤±5%, under vector control mode

Steady speed accuracy

OLVC: 0.2%; CLVC :0.01%

Torque response

≤5ms, under vector control

acceleration and deceleration time

0.0s~3200.0s;0.0min~3200.0min

Torque increase

0.0%~30.0%

Overload capacity

150% 1min/5min, 200% 3s/5min for heavy duty applications; Light load application 110% 1min/5min, 150% 10s/5min

VF curve

Linear type, multi-point type, V/F semi-separation mode, V/F complete separation mode

Input frequency resolution

Digital setting: 0.01Hz ; Analog setting: Maximum frequency ×0.025%

acceleration and deceleration curves

linear and S-curve acceleration and deceleration mode; Four acceleration and deceleration times, one emergency stop deceleration time

Jogging control

In some applications, the frequency converter needs to run at low speed for a short period of time to facilitate testing the condition of the equipment

Torque control

Torque control is possible when vector controlled

Simple PLC, multi-terminal speed

16 speed operation is achieved through the control terminal

Built-in PID

It can be easily formed as a closed-loop control system

Virtual IO

8 virtual VDI/VDO and 3 AI DI for simple logic control

Overvoltage and overcurrent stall control

Automatic current and voltage limit during operation to prevent frequent overcurrent and overvoltage tripping

DC braking

Start the DC brake and stop the DC brake

Pre-excitation

The motor is pre-excited when the frequency converter is started, and the magnetic field is established inside the motor, which can effectively improve the torque characteristics during the start of the motor

Overexcitation

It can effectively suppress the rise of bus voltage during the deceleration process, avoid frequent overvoltage faults, and realize rapid braking to meet the rapid stop of power outages

RPM tracking

Both asynchronous and synchronous machines support speed tracking function; Vector control and V/F control both support speed tracking function

Protection function

Overvoltage suppression, undervoltage suppression, V/F overcurrent suppression, ground short circuit protection, phase loss protection, speed deviation detection, overvoltage protection, overcurrent protection, undervoltage protection, overload protection, overtemperature protection, start protection, bus undervoltage point setting, bus overvoltage point setting, etc

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!