Visokofrekvenčni on-line UPS (3fazni vhod in 3fazni izhod)

  • High frequency on-line UPS (3phase in and 3phase out)

Ključne lastnosti

Znamka Switchgear parts
Model št Visokofrekvenčni on-line UPS (3fazni vhod in 3fazni izhod)
Moč 10KW
Frekvenčni obseg 50/60Hz
Kapaciteta 10kVA
Serija HBGS

Opisi izdelkov od dobavitelja

Opis

Serija HBGS v celoti obsega bistvo najnovejše tehnologije. Celotna naprava uporablja svetovno najnaprednejšo DSP digitalno nadzorno tehnologijo in tehnologijo nadzora z visoko frekvenco, s čimer ustvarja majhen obseg, lahkost in visoko učinkovitost: neničelni načrt preoblikovanja in tehnologija izhoda s čistim sinusnim valom zagotavljata, da je oprema uporabnika primerna za različne naprave. Z uporabo edinstvenega pretvorbnega obvoda AC-DC se preverja izhodni tok in napon strmi napajalne naprave. Preko visokofrekvenčnega modulatorja širine impulza se valovna oblika vhodnega toka sinhronizira z valovno obliko napona, kar omogoča dosego visokega vhodnega faktorja moči večjega od 95 %. V normalnih pogojih se preko obvoda AC-DC pridobi DCBUS-ov napon. Nato se DCBUS prevede v AC izhod preko inverterja, in vse bremena uporabljajo čist sinusni vir napajanja, ki je stabiliziran in očiščen od motenj. Uporaba odličnosti! Kot komponenta pretvorbe moči GBT, zaradi visokofrekvenčnih značilnosti BGT, omogoča, da UPS inverterji dosežejo delovno frekvenco 40KHz, s čimer se poveča učinkovitost inverterja in skupna učinkovitost UPS-a. Povečanje frekvence inverterja tudi zmanjša hrup inverterja. Zato postavitev serije HBG UPS neposredno v računalniški prostor ne bo vplivala na vašo delo. On-line visokofrekvenčni UPS serije HBG je povezan z omrežnim strežnikom preko komunikacijskega vmesnika RS232 in programske opreme za nadzor moči, s čimer zagotavlja trenutno stanje moči. Tako se tudi izvajajo inteligentne funkcije, kot so samodejni časovni pregled, avtomatsko shranjevanje, samodejno časovno vklop/izklop in beleženje stanja moči, s čimer se doseže ničelna razdalja med človekom in strojem. Ko je strmi vir napajanja prekinjen, UPS obvesti strežnik, da se pripravi na izklop in samodejno shrani vse podatke na disk, izvaja normalne ukaze za izklop. Tudi v brezosebni omrežni okolju lahko zagotovi varnost podatkov omrežnega sistema.

Uporabniško področje

Široko uporabljeno v upravnih centrih omrežij in računalniških centrih, bankah in borzi, davčnih uradih, komunikacijah, poštarskih storitvah, radiotelevizijskih, javnih varnostnih in prometnih organih. Pomembna področja podatkov, kot so električna energija, zdravstvo, industrijski nadzor in obramba.

 

Tehnični parametri

Model Specification 10KH(S) 15KH(S) 20KH(S) 30KH(S) 40KH(S) 60KH(S) 80KS 100KS 120KS 160KS 200KS
Phase Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output
Capacity 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW 80KVA/80KW 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW
Input                      
Rated Voltage 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load)
Frequency Range 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz
Power Factor ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load
Output                      
Output Voltage 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N)
Voltage Regulation (Battery Mode) ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1%
Frequency Range (Synchronous Tracking Range) 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz
Frequency Accuracy (Battery Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max)
Harmonic Distortion ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load)
Conversion Time                      
Mains to Battery 0 0 0 0 0 0 0 0 0 0 0
Inverter to Bypass 0 0 0 0 0 0 0 0 0 0 0
Waveform (Battery Mode) Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave
Overload                      
Mains Mode 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds
Battery Mode 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds
Parallel Capacity Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 2 units in parallel Up to 2 units in parallel Up to 2 units in parallel Up to 2 units in parallel Up to 2 units in parallel
Efficiency                      
Mains Mode 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 94.0% 94.0% 94.0% 94.0% 94.0%
ECO Mode 98.5% 98.5% 98.5% 98.5% 98.5% 98.5% 98.0% 98.0% 98.0% 98.0% 98.0%
Battery Mode 94.5% 94.5% 94.5% 94.5% 94.5% 94.5% 93.0% 93.0% 93.0% 93.0% 93.0%
Battery                      
Standard Unit                      
Battery Model 12V/9Ah 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah - N/A N/A N/A N/A N/A
Quantity (Cells) ±10 cells ×1 string ±16 cells ×1 string - ±16 cells ×2 strings - - N/A N/A N/A N/A N/A
Standard Charging Time 4 hours to 90% 4 hours to 90% - 4 hours to 90% - - N/A N/A N/A N/A N/A
Maximum Charging Current 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable - 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable - - N/A N/A N/A N/A N/A
Charging Voltage ±120VDC ±192VDC - ±120VDC/±192VDC - - N/A N/A N/A N/A N/A
Long-term Unit                      
Battery Model - - - Depends on Power Supply Time Depends on Power Supply Time Depends on Power Supply Time - - - - -
Quantity (Cells) ±10 cells ±16~±20 cells (Adjustable) - ±16~±20 cells (Adjustable) ±16~±20 cells (Adjustable) ±16~±20 cells (Adjustable) - - - - -
Maximum Charging Current 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable (Max 12A charging current) - 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable (Max 12A charging current) 12A 12A 16A 16A - -  
Charging Voltage ±13.65V × Number of Batteries (10) ±13.65V × Number of Batteries (16~20) - ±13.65V × Number of Batteries (16~20) ±13.65V × Number of Batteries (16~20) ±13.65V × Number of Batteries (16~20) - - - - -
Indicator Light                      
LCD Display System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication
Alarm Sound                      
Battery Mode Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds
Low Battery Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second
Overload Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second
Error Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep
Physical Performance                      
Standard Unit                      
Dimensions (W×D×H)mm 250X630X750 250X630X750 300 x815 x 1000 300 x815 x 1000 300 x815 x 1000 300 x815 x 1000 N/A N/A N/A N/A N/A
Net Weight (kgs) 109 126 139 225 250 - N/A N/A N/A N/A N/A
Long-term Unit                      
Dimensions (W×D×H)mm 250X630X750 250X630X750 300 x815 x 1000 300 x815 x 1000 360 x 790 x 1010 360 x 790 x 1010 550 x 850 x 1500 550x950x1700 650x1000x2100 - -
Net Weight (kgs) 43 43 43 60 61 108 113 150 185 - -
Operating Environment                      
Operating Temperature 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C
Humidity <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation
Noise Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m
Control Management                      
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC
Optional SNMP Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management
*Če je izhodna napetost nastavljena na 3x360VAC, se izhodna moč zmanjša na 90%
*Specifikacije strme struje so podvržene spremembam brez predhodnega obvestila
FAQ
Q: Kakšne prednosti ima viškofrekvenčni on-line UPS z 3faznim vhodom in 3faznim izhodom v primerjavi z drugimi vrstami tri-faznih UPS-jev
A:

 V primerjavi s nizko-frekvenčnimi tri-faznimi UPS in izvenmrežnimi tri-faznimi UPS ima očitne konkurenčne prednosti: ① Visoka učinkovitost & energijska ušteda: visoko-frekvenčna tehnologija dvojnega pretvorjenja zmanjša izgube energije za 15%~20% v primerjavi s nizko-frekvenčnimi modeli; učinkovitost v ECO načinu doseže 96%, kar znatno zniža dolgoročne stroške poslovanja; ② Kompaktnost & varčevanje prostora: manjša prostornina in lažja teža (30%~40% lažja kot nizko-frekvenčni UPS), kar pomeni varčevanje namestitvenega prostora za velike projekte (npr. podatkovne centre); ③ Stabilen tri-fazni izhod: uravnava tri-fazni obremenjevalni tok (toleranca neravnotežja ≤25%), nizka harmonična dekompozicija (THD <3%), primeren za občutljivo močno opremo (industrijski nadzorno-sistemski sistemi, medicinska MRI); ④ Hitro preklopilo & nič časa nedelovanja: <2ms brezmejno preklopilo na baterijsko napajanje, ki preprečuje prekinitev proizvodnje ali izgubo podatkov; ⑤ Močna razširljivost: podpora vzporednemu povezovanju 2~8 enot za razširitev kapacitete, da bi zadostila prihodnjim potrebam rastujoče obremenitve; ⑥ Inteligentno upravljanje: opremljen s LCD dotiknim zaslonom, podpora oddaljenemu nadzorovanju (SNMP/Modbus/4G), omogoča centralizirano upravljanje več UPS enot.

Q: Kaj je osrednja funkcija in delovanje visokofrekvenčnega on-line UPS (3fazni vhod in 3fazni izhod)?
A:

 To je močna neprekinjena električna oskrba, zasnovana za trofazne električne sisteme, predvsem za zaščito velikih naprav pred nepravilnostmi v električni mreži. Osnovne funkcije: ① Oskrba stabilnim trofaznim stromom, izolira nihanja napetosti, prekomerne napetosti, padce, harmonike in odrezovanje struje; ② Omogoča brezhibno preklapljanje na baterijsko energijo ob odpovedi omrežne napetosti (brez prekinitve) za zagotovitev zveznega delovanja opreme pod velikim obremenitvijo; ③ Uravnava trofazno obremenitev in utiša motnje v omrežju. Načelo delovanja: Uporaba visokofrekvenčne dvojne pretvorbe – trofazni strom vhod je pretvorjen v enosmerni tok s pravokotnikom, nato pa enosmerni tok ponovno pretvorjen nazaj v stabilen trofazni strom (čisti sinusni val) za uporabo pri obremenitvi; ko pride do odpovedi omrežne napetosti, baterijski paket takoj oskrbuje inverter z enosmerno energijo (čas preklopa <2ms); visokofrekvenčna zasnova (20kHz~50kHz) naredi UPS bolj kompakten in energijsko učinkovit kot nizkofrekvenčni trofazni UPS.

Poznajte svojega dobavitelja
Spletna trgovina
Stopnja pravočasne dobave
Čas odziva
100.0%
≤4h
Pregled podjetja
Delovni prostor: 1000m² Skupno število zaposlenih: Najvišja letna izvozna vrednost v dolarjih: 300000000
Delovni prostor: 1000m²
Skupno število zaposlenih:
Najvišja letna izvozna vrednost v dolarjih: 300000000
Storitve
Vrsta posla: Prodaja
Glavne kategorije: Opremi za opremo/Preverjanje opreme/Visokonapetostna oprema/Nizko napetostna oprema/merila in naprave/Proizvodno opremo/električni pribor
Trajni zavarovalni upravnik
Storitve upravljanja z vsoživljenjsko oskrbo za nabavo opreme, uporabo, vzdrževanje in servis po prodaji, ki zagotavljajo varno delovanje električne opreme, neprekinjen nadzor in brezskrbno porabo električne energije.
Dobavitelj opreme je opravil potrdilo o ustreznosti platforme in tehnično oceno, s čimer zagotavlja skladnost, strokovnost in zanesljivost že v izvoru.

Povezani izdelki

Povezane znanje

  • Nesreče glavnega transformatorja in težave pri delovanju lahkega plina
    1. Zapis o nesreči (19. marec 2019)Dne 19. marca 2019 ob 16:13 je nadzorno okolje poročalo o dejanju svetega plina na glavnem transformatorju št. 3. V skladu s Pravilnikom za delovanje močnih transformatorjev (DL/T572-2010) so održevalci (O&M) preverili stanje glavnega transformatorja št. 3 na mestu.Potrditev na mestu: Na plošči neelektrične zaščite WBH glavnega transformatorja št. 3 je bil zaznan dejanje svetega plina v faznem B delu transformatorja, ponovno postavitev pa ni bila učinkovita
    02/05/2026
  • Napake in njihova obdelava pri enofaznem talom v 10kV distribucijskih črtah
    Značilnosti in naprave za zaznavanje enofaznih ozemljitvenih okvar1. Značilnosti enofaznih ozemljitvenih okvarCentralni alarmni signali:Zazvoni opozorilni zvon in se prižge kazalna lučka z napisom »Ozemljitvena okvara na [X] kV avtobusu, odsek [Y]«. V sistemih z izgubno tuljavo (tuljavo za ugasitev loka) za ozemljitev srednje točke se prav tako prižge kazalna lučka »Izgubna tuljava v obratovanju«.Indikacije voltmetra za nadzor izolacije:Napetost okvarjene faze se zmanjša (pri nepopolni ozemljitv
    01/30/2026
  • Neutralni točka povezava za transformatorje elektroenergetskega omrežja 110kV~220kV
    Način zemljanja neutralne točke transformatorjev v omrežju napetosti 110kV~220kV mora zadostovati zahtevam izolacije neutralne točke transformatorja in se prav tako truditi ohraniti neničelno impedanco preobrazovalnic praktično nespremenjeno, hkrati pa zagotavlja, da neničelna celostna impedanca pri katerikoli kratkoporočni točki v sistemu ne presega trikratnice pozitivne celostne impedanci.Za 220kV in 110kV transformatorje v novih gradnji in tehničnih prenovah morajo njihovi načini zemljanja ne
    01/29/2026
  • Zakaj podstanice uporabljajo kamenje šiske male kamenčke in drobljen kamen
    Zakaj podstanice uporabljajo kamen, grud, krike in drobljen kamen?V podstanicah je za opremo, kot so prenosni in distribucijski transformatorji, prenosne linije, napetostni transformatorji, tokovni transformatorji in odskokne vložke, potrebno zemljenje. Poleg zemljenja bomo zdaj podrobneje raziskali, zakaj so gruda in drobljen kamen v podstanicah pogosto uporabljana. Čeprav izgledajo običajno, imajo ti kameni ključno vlogo za varnost in funkcionalnost.V načrtovanju zemljenja podstanic—zlasti, ko
    01/29/2026
  • Zakaj mora biti jedro transformatorja zazemljeno le na eni točki Ne bi bilo večtočkovno zazemljanje bolj zanesljivo
    Zakaj je potrebno zemljiti jedro transformatorja?Med delovanjem se jedro transformatorja skupaj s kovinskimi strukturami, deli in komponentami, ki fiksirajo jedro in viklinke, nahajajo v močnem električnem polju. Pod vplivom tega električnega polja pridobijo relativno visok potencial glede na zemljo. Če ni zemljitev jedra, bo obstajala razlika potencialov med jedrom in zemljenimi priklopni strukturami ter rezervoarjem, kar lahko vodi do intermitentnega izboja.Dodatno, med delovanjem okoli viklin
    01/29/2026
  • Razumevanje nevtralnega priključka transformatorja
    I. Kaj je nevtralna točka?V transformatorjih in generatorjih je nevtralna točka določena točka v zavojnici, kjer je absolutna napetost med to točko in vsakim zunanjim terminalom enaka. Na spodnjem diagramu točkaOprikazuje nevtralno točko.II. Zakaj je potrebno nevtralno točko zazemliti?Električna povezava med nevtralno točko in zemljo v sistemih trofazne stromo napetosti se imenujemetoda zazemljanja nevtralne točke. Ta način zazemljanja neposredno vpliva na:Varnost, zanesljivost in ekonomičnost e
    01/29/2026
Še niste našli pravilnega dobavitelja Pustite preverjene dobavitelje, da vas najdejo Pridobi Ponudbo Tujma
Še niste našli pravilnega dobavitelja Pustite preverjene dobavitelje, da vas najdejo
Pridobi Ponudbo Tujma
Povpraševanje
+86
Kliknite za nalaganje datoteke
Prenos
Pridobite IEE Business aplikacijo
Uporabite aplikacijo IEE-Business za iskanje opreme pridobivanje rešitev povezovanje z strokovnjaki in sodelovanje v industriji kjer in kdajkoli popolnoma podpira razvoj vaših električnih projektov in poslovanja