• New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
  • New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
  • New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
$300000.00
Model
SCC-600
SCC-450
Basic info
Brand Wone
Model NO. New Silicon Steel Sheet Automatic Cut to Length Line Machine for Transformer Lamination Core with Motor PLCS Industrial Use
Shearing thickness 0.23-0.35mm
Shearing width 60-640mm
Shearing length 600-3500mm
Weight of material >3000kg
Series SKJ
Product Detail

Features

  • lThe high accuracy of sheet feeding and cutting is guaranteed by precise photoelectric encoder, SIEMENS AC servo drive system and SIMOTION Motion controller. 

  • lCentral positioning for whole line guide width adjustment is controlled by computer.

  • lAdoption of graphic operation terminal with human-machine menu and colored processing pattern display enables operators to complete lamination shapes confirmation and parameters input through the touch screen.

  • lCompensation and achieves rapid adjustment of cutting length.

  • lCutting function and can cut step-lap lamination automatically.

  • lPreset number of sheets can be done automatically.Punching and shearing are driven by high dynamic servomotors, efficient with low noise.

  • lAutomatic stacking is adopted to stack silicon steel sheets from largest to smallest sizes or from smallest to largest sizes.

 Composition

(1). Double head decoiler    (2). Sheet guiding device    (3). Sheet feeder

(4). Punching unit    (5). Shearing unit    (6). Discharge table   (7). Diverting mechanism

(8). Stacking trolley   (9). Control cabinet    (10). Operating console

Specifications

Item

SKJ450

SKJ600

Shearing thickness

0.23-0.35mm

0.23-0.35mm

Shearing width

40-450mm

60-640mm

Shearing length

340-2000mm

600-3500mm

Punching aperture

customized

customized

Feeding speed

240m/min

240m/min

Shear rate (length 1000 mm)

50 piece/min

50 piece/min

Shearing accuracy

±0.1

±0.1

Shearing angel accuracy

±0.01°

±0.01°

Shearing burrs

0.02mm

0.02mm

Outer diameter of coiled material

No more thanφ1000mm

No more thanφ1000mm

Coil I.D.

φ500mm

φ500mm

Weight of material

No more than 1500kg

No more than 3000kg

Spindle telescoping range of decoiler

φ470-φ520mm

φ470-φ520mm

Carried material table height

No more than 200 mm

No more than 300 mm

Discharge direction

Transverse

Transverse

41f079f02aa0afba2393a26d2eeec6e0.jpeg

d5764ac4a5f6f4b369fc089f8a869df8.jpeg

Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!