• HD11F, HS11F series single throw and double throw protective knife switches
  • HD11F, HS11F series single throw and double throw protective knife switches
  • HD11F, HS11F series single throw and double throw protective knife switches
HD11F, HS11F series single throw and double throw protective knife switches
discuss personally
Model
HS11F-100-1000A
HD11F-100-1500A
Basic info
Brand Switchgear parts
Model NO. HD11F, HS11F series single throw and double throw protective knife switches
Rated normal current 100-1000A
number of poles 3P,4P
Series HD11F, HS11F
Product Detail

Applicable scope

The HD11F and HS11F series single throw and double throw protective knife switches are newly developed products derived from HD11 and HS11 by our company.

They are ideal substitutes for HD11 and HS11, greatly improving personal safety protection performance and preventing accidental electric shock.

This series of products is mainly used in low-voltage distribution equipment for infrequent manual connection, disconnection, and isolation of power supply.

This product complies with the GB14048.3 IEC60947-3 standard.

Normal working and installation conditions

The ambient air temperature shall not be higher than+40 ℃ and not lower than -5 ℃

The elevation of the installation site shall not exceed 2000m

Humidity: When the maximum temperature is+40 ℃, the relative humidity of the air does not exceed 50%. Higher relative humidity can be allowed at lower temperatures, such as reaching 90% at 20 ℃. Corresponding measures should be taken for occasional condensation caused by temperature changes

The pollution level of the surrounding environment is Level 3

The switch should be installed in a place without significant shaking, shock vibration, and rain or snow invasion. The same installation location should have no explosive hazardous medium, and there should be no gas or dust in the medium that is sufficient to corrode metal and damage insulation.protective knife switches

Main technical parameters

Agreed heating current (A) 100 200 400 600 1000 1500
Rated working current (A) 100 200 400 600 1000 1500
Rated insulation voltage (V) 1000 1000 1000 1000 1000 1000
Rated working voltage (V) 400/690 400/690 400/690 400/690 400/690 400/690
Mechanical life (times) 8000 8000 5000 5000 3000 3000
Short time withstand current for 1 second(KA) 10 10 15 20 25 35
Operating force (N) ≤300 ≤300 ≤400 ≤400 ≤450 ≤450

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!