• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


H61 50kVA-160kVA Distributio Transformer

  • H61 50kVA-160kVA Distribution Transformer
  • H61 50kVA-160kVA Distribution Transformer

Attributa principalia

Marca Vziman
Numerus Modeli H61 50kVA-160kVA Distributio Transformer
Capacitas nominata 160kVA
Series H61 Distribution Transformer

Descriptiones productorum a fornitori

Descriptio

Product overview:

H61 series distribution transformer made by WONE, is an oil type transformer conforming to IEC 60076 standard, which can meet the needs of different countries. H61 oil immersed transformer is suitable for overhead distribution network in rural and urban surrounding areas. The upper incoming line is adopted for high voltage and the side outgoing line is adopted for low voltage, which is equipped with triangular lightning arrester.

  • Standard: IEC 60076 (Publications 1-2-3-4 and 5); D60-p60 onee power sector.

  • Rated power: 50kva-100kva-160kva.

  • Working voltage: high voltage: 3.3kV to 36kV; Low voltage: 400-430 V.

  • Other specific voltages can be provided according to customer requirements.

Product parameters:

  • Composition of H61 distribution transformer.

  • 3 HV ceramic insulator.

  • 4 LV ceramic insulators.

  • Triangular lightning arrester.

  • Temperature measurement .

  • Pressure relief valve.

  • Oil level gauge.

  • 4 lifting lugs.

  • Four pulleys are welded at the bottom of the water tank.

  • 2 grounding.

  • Nameplate, warranty.

What is a Distribution Transformer?

Distribution transformers are key equipment in the power system used to convert high-voltage electrical energy into low-voltage electrical energy suitable for users. They serve as a bridge in the transmission and distribution systems, ensuring the safe and efficient transmission of electrical energy from high-voltage transmission lines to the user end.

Distribution transformers: Transformers specifically designed to convert high-voltage electrical energy (such as 10 kV, 35 kV) into low-voltage electrical energy (such as 400 V, 220 V) for users.


Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 10000m² Numerus omnium laborantium: 300 Summa Annua Exportatio (USD): 150000000
Locus Operis: 10000m²
Numerus omnium laborantium: 300
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Identificatio Risorum et Mensorum Controli pro Operibus Substitutionis Transformatoris Distributionis
    1. Praeventio et Controulus Periculi Fulgoris ElectriciIuxta standards designi typici pro renovationibus rete distributionis, distantia inter fusibile cadens transformatoris et terminale alta tensio est 1.5 metri. Si grua ad substitutionem utitur, saepe impossibile est retinere praescriptam minimum clearance securitatis 2 metri inter brachium gruae, apparatus levandi, funes, funes filiferae, et partes vivae 10 kV, quod periculum grave fulgoris electrici praebet.Mensurae Controuli:Mensura 1:Exsti
    12/25/2025
  • Analyse communium faultorum et causarum in inspectione ordinaria distributionis transformatorum
    Frequentes Causae et Defectus in Inspectione Ordinaria Transformatorum DistributionisUt componentes terminales systematum transmissionis et distributionis electricitatis, transformatores distributionis iocum crucialem ludunt in suppeditatione electricitatis fidei dignae ad usus finales. Tamen, multi usuarii habent cognitionem limitatam de apparatu electrico, et inspectio ordinaria saepe fit sine auxilio professionali. Si quaevis ex conditionibus sequentibus observantur in operatione transformato
    12/24/2025
  • Analyse praesidii fulminis ad transformatores distributionis
    Analysis of Fulguris Protection Measures for Distribution TransformersTo prevent fulguris surge intrusion and ensure the safe operation of distribution transformers, this paper presents applicable fulguris protection measures that can effectively enhance their fulguris withstand capability.1. Fulguris Protection Measures for Distribution Transformers1.1 Install surge arresters on the high-voltage (HV) side of the distribution transformer.According to SDJ7–79 Technical Code for Overvoltage
    12/24/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum