• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


GRV8-1UVS Single Phase Under Voltage Relay

  • GRV8-1UVS Single Phase Under Voltage Relay

Key attributes

Brand MV Switchgear Accessories
Model NO. GRV8-1UVS Single Phase Under Voltage Relay
Rated frequency 45Hz-65Hz
Series GRV8

Product descriptions from the supplier

Description

Product Highlight:

Precise Voltage Monitoring: Utilizes True RMS measurement for accurate voltage detection across diverse power conditions.

Adjustable Settings: Customize under voltage thresholds and trip delays to suit specific application needs.

Broad Frequency Compatibility: Operates effectively within a 45Hz to 65Hz range, accommodating various power systems.

Visual Feedback: Integrated LED indicators provide clear, real-time status updates for quick diagnostics.

Space-Saving Design: Compact 1-MODULE format with DIN rail mounting for easy integration into control panels.

The GRV8-1UVS is a high-performance single phase under voltage relay engineered to safeguard critical equipment from damaging voltage drops. Ideal for industrial, commercial, and HVAC applications, this relay ensures reliable protection for sensitive loads like motors, compressors, and air conditioning systems. With its compact design and advanced monitoring capabilities, the GRV8-1UVS is a trusted solution for maintaining operational stability.

Rated Voltage: AC 220V / 230V / 240V

Frequency Range: 45Hz – 65Hz

Measurement Accuracy: <1%

Under Voltage Range: Adjustable (e.g., 160V – 210V)*

Trip Delay Time: Adjustable (e.g., 0.1s – 10s)*

Item GRV8-1UVS
Function Under voltage
Monitoring terminials L-N
Supply terminals L-N
Rated supply voltage(Un) 220V/230V/240V
Rated supply frequency 45Hz-65Hz
Under voltage threshold S:70%-95%of Un
Trip delay time(Tu) 0.1s
Hysteresis 5V
Measurement error ≤1%
Power on delay time(Td) Adjustable: 5min-15min
Recovery delay time(Tr) Adjustable: 5min-15min
Konb setting accuracy 10% of scale value
Supply indication green LED
Output indication red LED
Output 1×SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Mechanical life 1*107
Electrical life(AC1) 1*105
Operating temperature -20℃ to +55℃(-4℉ to 131℉)
Storage temperature -35℃ to +75℃(-22℉ to 158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category III
Pollution degree 2
Max.cable size(mm²) solid wire max.1*2.5 or 2*1.5/with sleeve max.1*2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90×18×64mm
Weight 63g,65g
Standards EN 60255-1,IEC60947-5-1

Trip Delay Time: Adjustable (e.g., 0.1s – 10s)*

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.