• DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
  • DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS22B-550D/5000-63
DS22B-550D/4000-63
DS22B-420D/3150-63
DS22B-363D/5000-63
DS22B-363D/4000-63
DS22B-252D/5000-63
DS22B-252D/4000-63
DS22B-252D/3150-50
DS22B-252D/2000-50
DS22B-145D/2500-50
DS22B-126D/4000-50
DS22B-126D/3150-50
DS22B-126D/2000-50
Basic info
Brand ROCKWILL
Model NO. DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS22B
Product Detail

Product introduction

DS22B Switch Disconnector is a kind of outdoor HV electricity transmission equipment at three-phase AC frequency of 50Hz/60Hz. it is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way he electricity runs is changed, in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product is in the single-post single arm vertical telescopic structure. The contact is of the forceps-type, Vertical insulating breaks will be formed after the opening. The product can be used as an disconnect switch for bus. it is directly installed directly under the bus and only occupies a small space. JW10 earthing switch can be attached for grounding the bus at the lower layer, The grounding for the bus at the upper layer requires an independent earthing switch. 363kV and 550kV switch Disconnector and earthing switch are equipped with the SRCJ2 motor actuator for the single pole operation, Meanwhile, the tre-pole linkage can be achieved, The 126kV and 252kV isolating switches adopt SRCJ7 and SRCJ3 motor-based actuators to realize the tri-pole linkage. The grounding switch adopts CS11 and SRCS manual actuators to actualize tri-pole linkage.

This switch Disconnector has passed the verification by the review procedure organized by China Machinery industry federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internal level of the same kinds of products.

DS22B switch Disconnector comprises three single poles and actuator, Each single pole is made of a base, post insulator operating insulator and conductive part. The conductive part includes the gear box and foldable conductive arm fixed on the top of the post insulator, and the fixed contact hanging on the overload bus.

The actuator drives the operating insulator, and through the ink lever-driven conducive arm, if and lower the insulator to tighten or separate the moving contact and fixed contact on the directly overhead bus line to open or close the disconnect switch. After the opening, a vertical insulating break will be formed.

Main characteristic

  • State-of-art structure: The switch Disconnector is in the single-arm, foldable and telescopic structure, The driving elements and balancing springs are sealed within the conductive tube to reduce their adverse effects on natural environment and render the appearance compact and simple; The drive base adopts a link lever, Compared with angular wheels, the product is simpler and easier to adjust.
  • Superior conductance system: The conductive part made of Al-alloy of high conductance rate is characteristic of good conductance, high mechanical strength, light weight and strong corrosion resistance; The current will pass through the foldable area of the conductive arm via soft connection (without recourse to any movable contacts) to ensure reliable conductance, few maintenance, no examination, and long-term reliable operation.
  • Stable static contact structure:The hanging fixed contact is fixed with a pure alloy conductor ring to realize high degree of current flow capacity, The fixed contacts are hanged and fixed with the steel wires in the triangle shape to ensure the adjustment friendliness, stability and the reduction in vertical displacement.
  • Provide one-key sequential control "double confirmation" function expansion.
  • Unique forceps-type contact: The contact is of the forceps-type. The moving knife switch will be additionally accompanied by the extremal spring to ensure the constant contact pressure. The lower end of the knife switch is in sot connection with the base (without recourse to any movable contacts) to ensure reliable conductance and avoid the over-heating from poor contact The base for the moving contact is welded with the upper guide tube to prevent the water from penetrant into the milling mouth of the clamping head, The connection between the base of the contact and the draw rod is uniquely sealed to ensure no water penetration or accumulation at the base for the movable contact, In this way, the rust of parts within the conducive arm or the obstacles to the movement of the contact as a result of the ice coating in winter will be eliminated, and the failure of the disconnect switch to be opened or closed will also be avoided; The arc contact can be mounted onto the movable and fixed contacts to enable the switch Disconnector to switch current capacitive and inductive current by opening and closing bus line.
  • Simple and superior earthing switch: 363kV and above earthing switch is in the single-arm standing and openable structure, with the structurally simple plug-type contact. The conductive rod for grounding will move in two steps at the moments of opening and closing. At the moment of closing, the conductive rod will rotate vertically and rise up lo the fixed contact, and then automatically plug itself into the star-shaped contact. By doing so, the contact will be made reliable and be able to sustain the heavy short-circuit current.

Main technical parameters

Order notice 

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

It can be decided whether a earthing switch should be attached to the switch Disconnector;

It must be decided whether the upper bus line of the switch Disconnector is soft or hard. Additionally, the external diameter of the tubular busbar shall be specified;

It must be decided whether the disconnect switch is arranged in cross-over or parallel form;

The actuator's model, motor's voltage, control voltage and the number of contacts for auxiliary switch.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul