Key attributes

Brand Switchgear parts
Model NO. DNT-R1J series Semiconductor equipment protection fuse links
Rated voltage AC 1300V
Rated normal current 630-1250A
Breaking capacity 100kA
Series DNT-R1J

Product descriptions from the supplier

Description

How do environmental factors like temperature or humidity affect the performance of semiconductor fuses?

 Environmental factors, particularly temperature and humidity, can significantly affect the performance and reliability of semiconductor fuses. Here’s a closer look at how these factors impact fuse operation:

1.Temperature Effects:

Temperature Coefficient: Most fuse elements have a positive temperature coefficient, meaning their resistance increases with temperature. As the temperature rises, the fuse element heats up, and its resistance increases, which can lead to a reduction in current carrying capacity. In extreme cases, this might cause the fuse to open (blow) under normal current conditions.

Derating: Fuses are often derated for high ambient temperatures. Manufacturers usually provide derating curves that show how the current rating of the fuse should be reduced based on the ambient temperature. Operating a fuse at a higher temperature than it is rated for can significantly shorten its life and increase the likelihood of premature failure.

Thermal Endurance: Long-term exposure to high temperatures can degrade the materials used in the fuse, potentially leading to failures. This degradation can be accelerated by factors such as thermal cycling, where the fuse is repeatedly heated and cooled.

2.Humidity Effects:

Corrosion: High humidity can lead to corrosion of the metal parts in the fuse, particularly the end caps and the fuse element itself. Corrosion can increase the resistance of the fuse element and potentially lead to overheating and failure.

Moisture Ingress: If moisture penetrates the fuse body, it can cause short-circuiting, especially in fuses that are not hermetically sealed. This can be a significant issue in environments where condensation is likely to occur.

Deterioration of Insulation: Humidity can also deteriorate any insulation material in or around the fuse, potentially leading to electrical leakage or short-circuits.

3.Combined Temperature and Humidity Effects:

Accelerated Aging: The combination of high temperature and high humidity can accelerate the aging process of fuses. Materials used in the fuse may deteriorate faster under these conditions, reducing the fuse’s lifespan.

Thermal Shock: Rapid changes in temperature, especially when combined with humidity, can cause thermal shock. This can lead to physical stress and potential damage to the fuse structure.

To mitigate these environmental impacts:

Select Appropriate Fuses: Choose fuses that are designed to operate in the specific environmental conditions they will be exposed to. This might include fuses with higher temperature ratings or those designed to resist corrosion and moisture ingress.

Environmental Protection: Implement environmental control measures, such as maintaining a controlled temperature and humidity level, using enclosures to protect fuses from direct exposure to harsh conditions, or employing conformal coatings to provide additional protection against moisture and contaminants.

Regular Maintenance and Inspection: Regularly inspect fuses for signs of corrosion, damage, or other deterioration due to environmental factors. Replace any fuses that show signs of damage or that have been in service beyond their recommended lifespan.

By understanding and managing the impact of environmental factors like temperature and humidity, the reliability and performance of semiconductor fuses in various applications can be maintained effectively.

Basic parameters of fuse links

Product model size Rated voltage          V Rated current         A Rated breaking  capacity    kA
DNT1-R1J-160 1 AC 1300 160 100
DNT1-R1J-200 200
DNT1-R1J-250 250
DNT1-R1J-315 315
DNT1-R1J-350 350
DNT1-R1J-400 400
DNT1-R1J-450 450
DNT1-R1J-500 500
DNT1-R1J-550 550
DNT2-R1J-350 2 350
DNT2-R1J-400 400
DNT2-R1J-450 450
DNT2-R1J-500 500
DNT2-R1J-550 550
DNT2-R1J-630 630
DNT2-R1J-710 710
DNT2-R1J-800 800
DNT3-R1J-630 3 630
DNT3-R1J-710 710
DNT3-R1J-800 800
DNT3-R1J-900 900
DNT3-R1J-1000 1000
DNT3-R1J-1100 1100
DNT3-R1J-1250 1250
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.