• DNT-R1J series Semiconductor equipment protection fuse links
  • DNT-R1J series Semiconductor equipment protection fuse links
  • DNT-R1J series Semiconductor equipment protection fuse links
DNT-R1J series Semiconductor equipment protection fuse links
discuss personally
Model
DNT3-R1J-630-125A/AC 1300V/100kA
DNT2-R1J-350-800A/AC 1300V/100kA
DNT1-R1J-160-550A/AC 1300V/100kA
Basic info
Brand Switchgear parts
Model NO. DNT-R1J series Semiconductor equipment protection fuse links
Rated voltage AC 1300V
Rated normal current 630-1250A
Breaking capacity 100kA
Series DNT-R1J
Product Detail

How do environmental factors like temperature or humidity affect the performance of semiconductor fuses?

 Environmental factors, particularly temperature and humidity, can significantly affect the performance and reliability of semiconductor fuses. Here’s a closer look at how these factors impact fuse operation:

1.Temperature Effects:

Temperature Coefficient: Most fuse elements have a positive temperature coefficient, meaning their resistance increases with temperature. As the temperature rises, the fuse element heats up, and its resistance increases, which can lead to a reduction in current carrying capacity. In extreme cases, this might cause the fuse to open (blow) under normal current conditions.

Derating: Fuses are often derated for high ambient temperatures. Manufacturers usually provide derating curves that show how the current rating of the fuse should be reduced based on the ambient temperature. Operating a fuse at a higher temperature than it is rated for can significantly shorten its life and increase the likelihood of premature failure.

Thermal Endurance: Long-term exposure to high temperatures can degrade the materials used in the fuse, potentially leading to failures. This degradation can be accelerated by factors such as thermal cycling, where the fuse is repeatedly heated and cooled.

2.Humidity Effects:

Corrosion: High humidity can lead to corrosion of the metal parts in the fuse, particularly the end caps and the fuse element itself. Corrosion can increase the resistance of the fuse element and potentially lead to overheating and failure.

Moisture Ingress: If moisture penetrates the fuse body, it can cause short-circuiting, especially in fuses that are not hermetically sealed. This can be a significant issue in environments where condensation is likely to occur.

Deterioration of Insulation: Humidity can also deteriorate any insulation material in or around the fuse, potentially leading to electrical leakage or short-circuits.

3.Combined Temperature and Humidity Effects:

Accelerated Aging: The combination of high temperature and high humidity can accelerate the aging process of fuses. Materials used in the fuse may deteriorate faster under these conditions, reducing the fuse’s lifespan.

Thermal Shock: Rapid changes in temperature, especially when combined with humidity, can cause thermal shock. This can lead to physical stress and potential damage to the fuse structure.

To mitigate these environmental impacts:

Select Appropriate Fuses: Choose fuses that are designed to operate in the specific environmental conditions they will be exposed to. This might include fuses with higher temperature ratings or those designed to resist corrosion and moisture ingress.

Environmental Protection: Implement environmental control measures, such as maintaining a controlled temperature and humidity level, using enclosures to protect fuses from direct exposure to harsh conditions, or employing conformal coatings to provide additional protection against moisture and contaminants.

Regular Maintenance and Inspection: Regularly inspect fuses for signs of corrosion, damage, or other deterioration due to environmental factors. Replace any fuses that show signs of damage or that have been in service beyond their recommended lifespan.

By understanding and managing the impact of environmental factors like temperature and humidity, the reliability and performance of semiconductor fuses in various applications can be maintained effectively.

Basic parameters of fuse links

Product model size Rated voltage          V Rated current         A Rated breaking  capacity    kA
DNT1-R1J-160 1 AC 1300 160 100
DNT1-R1J-200 200
DNT1-R1J-250 250
DNT1-R1J-315 315
DNT1-R1J-350 350
DNT1-R1J-400 400
DNT1-R1J-450 450
DNT1-R1J-500 500
DNT1-R1J-550 550
DNT2-R1J-350 2 350
DNT2-R1J-400 400
DNT2-R1J-450 450
DNT2-R1J-500 500
DNT2-R1J-550 550
DNT2-R1J-630 630
DNT2-R1J-710 710
DNT2-R1J-800 800
DNT3-R1J-630 3 630
DNT3-R1J-710 710
DNT3-R1J-800 800
DNT3-R1J-900 900
DNT3-R1J-1000 1000
DNT3-R1J-1100 1100
DNT3-R1J-1250 1250
Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!