• HD11F series (Model G) Open knife switch with protective cover
  • HD11F series (Model G) Open knife switch with protective cover
HD11F series (Model G) Open knife switch with protective cover
discuss personally
Model
HD11F-200-1000A
Basic info
Brand Switchgear parts
Model NO. HD11F series (Model G) Open knife switch with protective cover
Rated voltage AC 400V/AC 690V
Rated normal current 200-1000A
number of poles 3P,4P
Series HD11F
Product Detail

This series of products are mainly used in low-voltage distribution equipment for infrequent manual connection, disconnection and isolation of power supply.

This product conforms to GB/T14048.3 IEC60947-3 standard.

The ambient air temperature is not higher than +40 ℃ and not lower than -5 ℃.

The altitude of the installation site shall not exceed 2000m.

Humidity: when the maximum temperature is +40 ℃, the relative humidity of the air does not exceed 50%. At a lower temperature, a higher relative humidity can be allowed, such as 90% at 20 ℃. Corresponding measures should be taken for the occasional condensation due to temperature changes.Open knife switch

The pollution level of the surrounding environment is level 3.

The switch shall be installed in a place without significant shaking, shock vibration and rain and snow invasion. At the same time, the installation place shall be free of explosive dangerous medium, and the medium shall be free of gas and dust sufficient to corrode metal and damage insulation.

The insulating material of the product can reach flame retardant VO level.

Agreed heating current (A)

250

400 630

1000

Rated working current (A)

100/160

200/250 400 630 1000
Rated insulation voltage (V)

1000

1000 1000 1000

1000

Rated working voltage (V)

400 / 690

400 / 690 400 / 690 400 / 690

400 / 690

Mechanical life (Times)

8000

8000 5000 5000

3000

1s short-time withstand current (kA)

6

10 15 12 25
Operating force (N)

≤ 100

≤ 150 150 250 250

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!