| Muhimmiya | Switchgear parts |
| Model NO. | Din rail mount fuse holder RT18-125-3P+N |
| Kwọnnye Nmeri | 3P+N |
| Siri | RT18-125-3P+N |
A cikin rail mount fuse holder yana iya amfani a hanyar AC (alternating current) da kuma DC (direct current) applications. Ingantaccen design da kuma specifications ta fuse holder zai taimaka wajen tabbatar da ya dacewa don AC ko DC circuits. A kan zaɓi na fuse holder, ita ce muhimmanci a duba abubuwa masu:
1.Voltage Rating: Duba cewa rating voltage ta din rail mount fuse holder yana dace don applicationka AC ko DC. Rating voltage ya kamata maza ko kudan voltage ta electrical systemka game da tabbacin insulation da kuma inganci.
2.Current Rating: Fara da rating current da take da shawarwari don circuitka, bane na AC ko DC applications. Fuse holders suna gina wajen kula da sauran ranges of current, saboda haka zaɓi holder wanda zai iya kula da maximum current da aka neman a cikin circuitka, bane na AC ko DC.
3.Construction and Design: Fuse holders na AC da kuma DC applications zai iya canza da farko na design don amsa da kyakkyawan cikin type daɗinsa. Misali, AC fuse holders zai iya canza da karfi mai karfi game da handling the alternating current's periodic voltage reversals. Amma, akwai kowane fuse holders suna gina wajen kula da AC da kuma DC currents.
4.Compliance with Standards: Duba cewa fuse holder yana da compliance da relevant safety and industry standards for both AC and DC applications.
Fuse Holder Types Tabbatar da certifications ko markings wadanda suke bayyana compliance da standards kamar UL (Underwriters Laboratories), CSA (Canadian Standards Association), ko IEC (International Electrotechnical Commission) for the specific voltage and current type you are working with.
Daga zaɓin fuse holder wanda yake da rating voltage da kuma current requirements na AC ko DC circuitka, zan iya tabbatar da suitability da kuma proper functioning a cikin applicationka.
Item No.DN56124
| Product model | RT18-125 |
| Description | Fuse switch disconnector, standard structure with null line at right |
| Pole | 3P+N |
| Mounting method | DIN rail installation |
| Wiring method | 4-50mm2 |
| Fuse size | 22*58 |
| Rated operational current le | 125A(500VAC)/100A(690VAC) |
| Rated operational voltage Ue | 500VAC/690VAC |
| Rated insulation voltage | 800V |
| Rated impulse withstangd current lpk | 6KV |
| Breaking capacity with fuse | 100KA(500VAC)/50KA(690VAC) |
| Utilization category with fuse | gG |
| LED Indicator voltage | 110-690VAC/DC |
| IP | IP20 |
| Reference standard | IEC 60269-2 GB/T 13539.2 |