Desktop Dissolved Gas Analysis Analyzer

Add us on Google
  • Desktop Dissolved Gas Analysis Analyzer

Key attributes

Brand ROCKWILL
Model NO. Desktop Dissolved Gas Analysis Analyzer
Signal output digits 24 Bit
Temperature control accuracy of column box ± 0.02℃
Display accuracy 0.01℃
Series DGA
Description

The Desktop Dissolved Gas Analysis Analyzer (DGA) determines dissolved gas content in the insulating oil of power system equipment. A single injection completes analysis of seven key fault gases (H₂, CO, CO₂, CH₄, C₂H₄, C₂H₆, C₂H₂) for early detection of latent overheating and discharge faults. Built-in remote control covers gas-path pressure display, temperature setting, one-key startup, ignition and current adjustment, while digital FID zero-adjustment ensures stable, reliable operation in grid preventive maintenance.

Main feature

  • Built - in remote control technology for intuitive display of instrument gas path pressure

  • Remote control technology for temperature setting and display operations of the instrument

  • Remote control technology for one - key startup

  • Computer remote control to complete operations such as ignition and current setting with a click

  • Digital FID electronic zero - adjustment technology to enhance the instrument's anti - interference ability

  • Thermal conductivity tungsten filament protection function against gas interruption

Technology parameters

Signal output digits 24 bit
Temperature control accuracy of column box ±0.01°C
Display accuracy 0.1°C
Gas pressure control accuracy 0.01 psi (upgradeable to 0.001 psi)
Maximum shunt ratio 8000:1
Gases analyzed (single injection) H₂, CO, CO₂, CH₄, C₂H₄, C₂H₆, C₂H₂
Minimum detection concentration C₂H₂ ≤ 0.1 ppm
TCD detector sensitivity S ≥ 3500 mV·mL/mg (benzene), up to 12000 mV·mL/mg
TCD baseline noise / drift ≤ 10 µV / ≤ 50 µV per 30 min
FID detector detection limit ≤ 5.0×10⁻¹² g/s (hexadecane)
FID baseline noise / drift ≤ 2×10⁻¹⁴ A / ≤ 1×10⁻¹³ A per 30 min
ECD detector detection limit ≤ 1.0×10⁻¹³ g/s (γ-666)
ECD baseline noise / drift ≤ 40 µV / ≤ 100 µV per 30 min
FPD detector detection limit ≤ 1.4×10⁻¹² g/s (P), ≤ 5×10⁻¹¹ g/s (S)
FPD baseline noise / drift ≤ 20 µV / ≤ 50 µV per 30 min
Expandability Up to 6 external events

Gas path process 

image.png

Schematic diagram

Schematic diagram of hydrogen flame ionization detector (FID)

Desktop Dissolved Gas Analysis Analyzer

Structural diagram of hydrogen flame ionization detector (FID)

Desktop Dissolved Gas Analysis Analyzer

Applicable Standards

GB/T 17623‑2017、DL/T 722‑2014、IEC 60599、IEEE C57.104

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register