Key attributes

Brand Wone Store
Model NO. DC MCCB molded case circuit breakers
Rated normal current 100A
Rated frequency 50/60Hz
Series PEMC

Product descriptions from the supplier

Description

Description

DC MCCB (DC Molded Case Circuit Breaker) is a core protection and control device specifically designed for DC power systems. It adopts a high-strength insulated molded case packaging structure and integrates functions of current detection, fault judgment, and instantaneous breaking. Its core role is to realize the reasonable distribution of electrical energy in DC power distribution circuits, while accurately identifying and quickly cutting off faults such as overload, short circuit, and undervoltage in the circuit. This prevents fault expansion from damaging DC power supplies, power distribution equipment, and downstream loads (such as energy storage systems, photovoltaic inverters, DC motors, etc.), making it a key component to ensure the stable and safe operation of DC power systems.

Features

  • Strong DC Breaking Capacity: Aiming at the characteristic of "difficult arc extinction" in DC circuits, it is equipped with a dedicated DC arc-extinguishing system (such as a multi-slit arc-extinguishing chamber and a magnetic blow device). The rated short-circuit breaking capacity (Ics) can reach several tens of kiloamperes (e.g., 50KA~100KA, depending on the specific model), which can quickly extinguish fault arcs and ensure breaking reliability.

  • Accurate Fault Protection: It supports multiple protection functions such as overload long-time delay, short circuit short-time delay, instantaneous short circuit, and undervoltage protection. The protection parameters can be flexibly set according to the rated current and load characteristics of the DC system, adapting to DC power distribution scenarios of different power levels.

  • Wide Voltage and Current Adaptability: The voltage level covers DC 24V~1500V (suitable for low-voltage and medium-voltage DC systems), and the rated current range is from several tens of amperes to several hundreds of amperes (e.g., 63A~630A). It can meet the power distribution needs of different scenarios such as energy storage power stations, data center UPS, and photovoltaic DC combiner boxes.

  • High Environmental Adaptability: It uses high and low temperature resistant, anti-aging insulating materials and a sealed structure. The operating temperature range can reach -30℃~+70℃, and it has a certain degree of dustproof and moisture-proof performance (some models meet the IP40 protection level), making it suitable for complex environments such as outdoors, computer rooms, and industrial workshops.

Technical Parameter

Product Model PEMC Series 1000V, 2P, 63A~800A PEMC Series 1500V, 2P, 225A~800A PEMC Series 1500V, 3P, 63A~800A
Rated working voltage Ue DC1000V DC1500V DC1500V
Rated working current Ie 63A~250A 225A~800A 280A~320A
Mechanical life 10000 times 10000 times 10000 times
Rated Insulation Voltage Ui 1250V 1500V 1500V
Release Type Thermal Magnetic Thermal Magnetic Thermal Magnetic
Electrical life 1500 times 1500 times 1500 times
Rated impulse withstand voltage Uimp 8kV 12kV 12kV
Breaking capacity Ics=Icu=20kA Ics=Icu=20kA Ics=Icu=20kA

High Craftsmanship and Standards

  • High voltage

  • Heat and humidity resistance

  • Zero arcing

  • Large distance

  • High life expectancy

  • Low temperature rise

  • Strong environmental adaptability

  • Maximum voltage DC 1500V, maximum current 800A

 

 

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Rockwill Passes Single-Phase Ground Fault Test for Smart Feeder Terminal
    Rockwill Electric Co., Ltd. has successfully passed the real-scenario single-phase-to-ground fault test conducted by the Wenzhou of China Electric Power Research Institute for its DA-F200-302 hood-type feeder terminal and integrated primary-secondary pole-mounted circuit breakers—ZW20-12/T630-20 and ZW68-12/T630-20—receiving an official qualified test report. This achievement marks Rockwill Electric as a leader in single-phase ground fault detection technology within distribution networks.The DA
    12/25/2025
  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.