• The high-voltage disconnect switch uses rod-shaped porcelain insulators
The high-voltage disconnect switch uses rod-shaped porcelain insulators
discuss personally
Model
ZCW1-252/N2.5-3
Basic info
Brand Wone Store
Model NO. The high-voltage disconnect switch uses rod-shaped porcelain insulators
Rated voltage 252kV
Rated frequency 50/60Hz
Series ZCW
Product Detail

Product Description

The high-voltage disconnect switch, which incorporates rod-shaped porcelain insulators, is a critical component in high-voltage power transmission and distribution systems. Its primary function is to provide visible isolation in electrical circuits during maintenance or emergency situations, ensuring the safety of operators and equipment. The rod-shaped porcelain insulators serve as both mechanical supports for the switch’s conductive parts and reliable insulation barriers, preventing electrical leakage and maintaining system stability even in harsh operating environments such as outdoor substations or industrial power grids.

Main Features

  • Superior Insulation Performance:The rod-shaped porcelain insulators offer excellent dielectric strength, effectively withstanding high voltage levels to prevent flashovers and ensure safe isolation between live parts and grounded structures.

  • Robust Mechanical Support:The sturdy porcelain construction provides strong mechanical stability, enabling the switch to withstand external forces like wind, vibration, and conductor tension, ensuring long-term structural integrity.

  • Weather and Pollution Resistance:The porcelain material is highly resistant to extreme temperatures, humidity, UV radiation, and industrial pollution, maintaining performance in outdoor and harsh industrial settings.

  • Clear Isolation Visibility:Designed to provide a distinct visible break in the circuit when opened, complying with safety standards and facilitating easy verification of isolation status.

  • Compatibility with High-Voltage Systems:Engineered to integrate seamlessly with high-voltage networks, supporting voltage levels typically used in transmission and distribution, and ensuring reliable operation in grid applications.

Main Parameters

Model

Factory code

Rated voltage

The damage load is not small

Creepage distance

Main Dimensions (mm)

weight




curved

torsion


Overall height

Maximum umbrella diameter

Upper mounting holes

lower mounting holes




kV

kN

kN.m

mm

H

D

D1-n-d1

D2-n-d2

kg

ZCW1-252/N2.5-3

229277

252


2.5

6300

2400

240

127-4-M16

127-4-M16

161

T2-1050-III

289205

252


3

6300

2400

240

127-4-M16

127-4-M16

117.3

ZCW1.1-252/N2-4

229303

252


2.5

7812

2400

255

127-4-M16

127-4-M16

148

T2-1050-IV

289204

252


3

7812

2300

210

127-4-M16

127-4-M16

123.0

C8-1050-III

289202

252

8

4

6300

2300

260

127-4-M16

254-8-Ф18

175.8

ZSW1.1-252/8-3

229287

252

8

8

6300

2300

265

140-4-M12

250-8-Φ18

200

ZSW1.6-252/8-3

229319

252

8

6

6300

2300

285

140-4-M12

250-8-Ф18

195

ZSW1.3-252/10-3

229322

252

10

8

6300

2400

285

127-4-M16

250-8-Ф18

223

ZSW1.4-252/10-3

229321

252

10

8

6300

2300

265

225-4-Ф18

250-8-Ф18

210

ZSW1.5-252/10-3

229327

252

10

8

6300

2300

265

140-4-M12

250-8-Ф18

196

ZSW1-252/12.5-3

229247

252

12.5

10

6300

2300

290

225-4-Ф18

275-8-Ф18

250

ZSW1.1-252/16-3

22944D

252

16

10

6300

2300

305

254-8-Ф18

300-8-Ф18

260

C8-1050-IV

289203

252

8

4

7812

2300

282

225-8-Ф18

254-8-Ф18

197.0

C8-1050-IV

289206

252

8

4

7812

2300

282

127-4-M16

254-8-Ф18

193.0

ZSW1.5-252/8-4

229320

252

8

6

7812

2400

316

140-4-M12

250-4-Ф18

244

ZSW1.7-252/8-4

229302

252

8

8

7812

2400

316

127-4-M16

250-8-Ф18

250

ZSW1.8-252/8-4

229306

252

8

8

7812

2400

341

225-4-Ф18

275-8-Ф18

298

ZSW1.3-252/10-4

229323

252

10

8

7812

2400

316

127-4-M16

286-6-Ф18

250

ZSW1.4-252/10-4

229324

252

10

8

7812

2400

316

225-4-Ф18

250-8-Ф18

251

ZSW1.1-363/8-3

289300

363

8

4

9080

3500

290

190-4-Ф18

300-4-Ф18

322

ZCW1-363/N4-3

289304

363


4

9080

3500

235

127-8-M10

127-8-M10

233

ZSW1-363/12-3

289306

363

12

6

9080

3500

315

127-4-M16

325-8-Ф18

378

ZCW1-550/N4L-3

22985

550


4

13750

4400

225

127-8-M10

127-8-M10

242

T4-1950-IV

289501

550


4

17050

4700

286

127-4-M16

127-4-M16

410.0

ZCW1.2-550/N4L-4

229565

550


4

17050

4700

290

127-8-M10

127-8-M10

373

ZSW1.1-550/12-3

229556

550

12

10

13750

4400

342

127-4-M16

325-8-Ф18

559

ZSW1.5-550/12-3

229556D

550

12

10

13750

4400

342

127-4-M16

325-8-Ф18

513

ZSW1.3-550/12-4

229564

500

12

10

17050

4700

364

127-4-M16

325-8-Ф18

668

C16-1950-IV

289500

550

16

10

17050

4700

384

225-4-Ф18

325-8-Ф18

707.0

ZSW1-800/16-3

229702

800

16

10

22400

6800

415

275-8-Ф18

375-8-Ф18

1308

ZSW1.1-800/16-3

229703

800

16

10

22400

6800

415

127-4-M16

375-8-Ф18

1296

ZSW1.4-800/16-3

229705B

800

16

10

21000

7200

405

275-8-Ф18

375-8-Ф22

1312

ZCW1-1100/N6-3

229813

1100


15

27500

9600

270

254-4-Ф18

254-4-Ф18

947

ZSW1.3-1100/16-3

229812

1100

16

15

27500

9600

411

300-10-Ф18

425-12-Ф22

2078

ZSW1.4-1100/16-3

229814

1100

16

17

30410

10500

460

275-8-Ф18

450-16-Ф24

2606

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!