• IEC series rod-shaped porcelain insulators
IEC series rod-shaped porcelain insulators
discuss personally
Model
c6-450
Basic info
Brand Wone Store
Model NO. IEC series rod-shaped porcelain insulators
Rated frequency 50/60Hz
Series c
Product Detail

Product Description

IEC series rod-shaped porcelain insulators are high-performance electrical insulation components designed in compliance with International Electrotechnical Commission (IEC) standards. They are primarily used in power transmission and distribution systems to provide reliable insulation and mechanical support for conductors, ensuring safe and stable operation of electrical networks.

Main Features

  • Compliance with IEC Standards:Manufactured strictly according to international IEC specifications, ensuring compatibility and interchangeability in global power projects.

  • Excellent Insulation Performance:Made of high-quality porcelain material with strong dielectric strength, effectively resisting electrical breakdown even in harsh environments.

  • Mechanical Durability:Robust rod-shaped structure withstands high mechanical loads, including tension, compression, and vibration, suitable for various installation conditions.

  • Weather Resistance:Resistant to extreme temperatures, humidity, pollution, and UV radiation, maintaining performance in outdoor and industrial settings.

  • Easy Installation:Designed for straightforward mounting in overhead lines, substations, and electrical equipment, reducing installation complexity and time.

Main Parameters

Number

Lightning impact adduction voltage

Operate the impact wet resistant point card

Power frequency wet withstand voltage

height

Minimum nominal creepage distance (mm)

Maximum creepage distance of insulation

Mechanical destruction load

Top metal attachment mounting hole center circle diameter

Bottom metal fitting mounting hole center circle diameter



III

IV

curved

torsion


kV

kV

kV

mm

mm

kN

kN·m

mm

mm

c6-450

450


185

1020±1

2500

3100

260

6

3.5

127

127/178

c8-450

450


185

1020±1

2500

3100

280

8

4

127

127/200

c10-450

450


185

1020±1

2500

3100

290

10

4

127

127/225

c12.5-450

450


185

1020±1

2500

3100

300

12.5

6

127

225

c16-450

450


185

1020±1

2500

3100

310

16

6

127

254

c20-450

450


185

1020±1

2500

3100

310

20

6

127

254

c6-550

550


230

1220±1

3150

3910

300

6

4

127

127/200

c8-550

550


230

1220±1

3150

3910

300

8

4

127

127/200

c10-550

550


230

1220±1

3150

3910

350

10

4

127

127/225

c12.5-550

550


230

1220±1

3150

3910

350

12.5

6

127

254

c16-550

550


230

1220±1

3150


350

16

6

127

254

c20-550

550


230

1220±1

3150


350

20

6

127

275

c6-650

650


275

1500±2.5

3630

4510

350

6

3

127

127/200

c8-650

650


275

1500±2.5

3630

4510

350

8

4

127/225

127/225

c10-650

650


275

1500±2.5

3630

4510

400

10

4

127/225

254

c12.5-650

650


275

1500±2.5

3630

4510

400

12.5

6

127/225

254

c16-650

650


275

1500±2.5

3630

4510

400

16

6

225

275

c20-650

650


275

1500±2.5

3630

4510

420

20

6

225

300

c6-750

750


325

1700±2.5

4250

5270

350

6

3

127/225

127/225

c8-750

750


325

1700±2.5

4250

5270

350

8

4

127/225

127/225

c10-750

750


325

1700±2.5

4250

5270

400

10

4

127/225

254

c12.5-750

750


325

1700±2.5

4250

5270

400

12.5

6

127/225

254

c16-750

750


325

1700±2.5

4250

5270

400

16

6

225/254

275

c20-750

750


325

1700±2.5

4250

5270

420

20

6

225/254

300

c6-850

850


360

1900±2.5

5100

6330

400

6

3

127/225

225

c8-850

850


360

1900±3.5

5100

6330

400

8

4

127/225

254

c10-850

850


360

1900±2.5

5100

6330

400

10

4

127/225

254

c12.5-850

850


360

1900±3.5

5100

6330

400

12.5

6

127/225/254

254

c16-850

850


360

1900±3.5

5100

6330

400

16

6

225/254

275

c20-850

850


360

1900±3.5

5100

6330

420

20

6

225/254

300

c8-950

950

750

395

2100±3.5

6300


450

8

4

127/225

254

c10-950

950

750

395

2100±3.5

6300


450

10

4

127/225

254

c12.5-950

950

750

395

2100±3.5

6300


450

12.5

6

127/225/254

275

c16-950

950

750

395

2100±3.5

6300


450

16

6

225/254

300

c20-950

950

750

395

2100±3.5

6300


450

20

6

225/254

325

c8-1050

1050

750

460

2300±3.5

6300

7820

450

8

4

127/225

254

c10-1050

1050

750

460

2300±3.5

6300

7820

450

10

4

127/225

275

c12.5-1050

1050

750

460

2300±3.5

6300


450

12.5

6

127/225/254

275

c16-1050

1050

750

460

2300±3.5

6300


450

16

6

225/254

300

c20-1050

1050

750

460

2300±3.5

6300


450

20

6

225/254

325

c8-1175

1175

850


2650±4.5

7500


450

8

4

127/225

254

c10-1175

1175

850


2650±4.5

7500


450

10

4

127/225

275

c12.5-1175

1175

850


2650±4.5

7500


450

12.5

6

127/225/254

300

c16-1175

1175

850


2650±4.5

7500


450

16

6

225/254

325

c20-1175

1175

850


2650±4.5

7500


450

20

6

225/254

356

c8-1300

1300

950


2900±4.5

9080


450

8

4

127/225

275

c10-1300

1300

950


2900±4.5

9080


450

10

4

127/225

275

c12.5-1300

1300

950


2900±4.5

9080


450

12.5

6

127/225/254

300

c16-1300

1300

950


2900±4.5

9080


450

16

6

225/254

325

c20-1300

1300

950


2900±4.5

9080


450

20

6

225/254

356

c8-1425

1425

950


3150±4.5

9080


450

8

4

127/225

275

c10-1425

1425

950


3150±4.5

9080


450

10

4

127/225

300

c12.5-1425

1425

950


3150±4.5

9080


450

12.5

6

127/225/254

325

c16-1425

1425

950


3150±4.5

9080


450

16

6

225/254

356

c20-1425

1425

950


3150±4.5

9080


450

20

6

225/254

356

c8-1550

1550

1050


3150±4.5

9080

11260

450

8

4

127/225

275

c10-1550

1550

1050


3350±4.5

9080

11260

450

10

4

127/225

300

c12.5-1550

1550

1050


3350±4.5

9080

11260

450

12.5

6

127/225/254

325

c16-1550

1550

1050


3350±4.5

9080

11260

450

16

6

225/254

356

c20-1550

1550

1050


3350±4.5

9080

11260

450

20

6

225/254

356

c8-1675

1675

1050


3650±5.5

10500


450

8

4

127/225

300

c10-1675

1675

1050


3650±5.5

10500


450

10

4

127/225

300

c12.5-1675

1675

1050


3650±5.5

10500


450

12.5

6

225/254

325

c16-1675

1675

1050


3650±5.5

10500


450

16

6

225/254

356

c20-1675

1675

1050


3650±5.5

10500


450

20

6

225/254

375

c8-1800

1800

1175


4000±5.5

13130


450

8

4

225/254

300

c10-1800

1800

1175


4000±5.5

13130


450

10

4

225/254

325

c12.5-1800

1800

1175


4000±5.5



450

12.5

6

225/254

356

c16-1800

1800

1175


4000±5.5



450

16

6

225/254

356

c20-1800

1800

1175


4000±5.5



450

20

6

225/254

375

c8-1950

1950

1300


4400±5.5

13750


450

8

4

225/254

325

c10-1950

1950

1300


4400±5.5

13750


450

10

4

225/254

325

c12.5-1950

1950

1300


4400±5.5

13750


450

12.5

6

225/254

356

c16-1950

1950

1300


4400±5.5

13750


450

16

6

225/254

356

c20-1950

1950

1300


4400±5.5

13750


450

20

6

225/254

375

c8-2100

2100

1300


4700±5.5

13750


450

8

4

225/254

300

c10-2100

2100

1300


4700±5.5

13750


450

10

4

225/254

325

c12.5-2100

2100

1300


4700±5.5

13750


450

12.5

6

225/254

356

c16-2100

2100

1300


4700±5.5

13750


450

16

6

254

356

c20-2100

2100

1300


4700±5.5

13750


450

20

6

254

375

c8-2250

2250

1425


5000±6.5

13750

17060

450

8

4

225/254

325

c10-2250

2250

1425


5000±6.5

13750

17060

450

10

4

225/254

356

c12.5-2250

2250

1425


5000±6.5

13750


450

12.5

6

225/254

356

c16-2250

2250

1425


5000±6.5

13750


450

16

6

254

375

c20-2250

2250

1425


5000±6.5

13750


450

20

6

254

400

c8-2400

2400

1425


5300±6.5

13750

17060

450

8

4

225/254

325

c10-2400

2400

1425


5300±6.5

13750

17060

450

10

4

225/254

356

c12.5-2400

2400

1425


5300±6.5

13750

17060

450

12.5

6

225/254

356

c16-2400

2400

1425


5300±6.5

13750

17060

450

16

6

254

375

c20-2400

2400

1425


5300±6.5

13750

17060

450

20

6

254

400

c8-2550

2550

1550


5700±6.5

19130


450

8

4

225/254

325

c10-2250

2550

1550


5700±6.5

19130


450

10

4

225/254

356

c12.5-2550

2550

1550


5700±6.5

19130


450

12.5

6

254

375

c16-2550

2550

1550


5700±6.5

19130


450

16

6

275

400

c8-2650

2650

1650


6300±7.5

20000


450

8

4

127/275

325

c10-2650

2650

1650


6300±7.5

20000


450

10

4

127/275

356

c12.5

2650

1650


6300±7.5

20000


450

12.5

6

127/275

375

c16-2650

2650

1650


6300±7.5

20000


450

16

6

127/275

400

c10-2750

2750

1700


6800±8.0

20000


450

10

4

127/275

356

c12.5-2750

2750

1700


6800±8.0

20000


450

12.5

6

127/275

375

c16-2750

2750

1700


6800±8.0

20000


450

16

6

127/275

400

c10-2850

2850

1750


7200±8.5

20000


450

10

4

127/275

356

c12.5-2850

2850

1750


7200±8.5

20000


450

12.5

6

127/275

375

c16-2850

2850

1750


7200±8.5

20000


450

16

6

127/275

400

c10-3000

3000

1800


8400±9.5

27500


500

10

4

127/275

375

c12.5-3000

3000

1800


8400±9.5

27500


500

12.5

6

127/275

400

c16-3000

3000

1800


8400±9.5

27500


500

16

6

127/300

400

c10-3200

3200

1950


10000±11.5

27500


500

10

4

127/275

375

c12.5-3200

3200

1950


10000±11.5

27500


500

12.5

6

127/300

400/425

c16-3200

3200

1950


10000±11.5

27500


500

16

6

127/300

425/450

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!