Compact UHV Gas‑Insulated Switchgear for Transmission Substation-800kV

Add us on Google
  • Compact UHV Gas‑Insulated Switchgear for Transmission Substation-800kV

Key attributes

Brand ROCKWILL
Model NO. Compact UHV Gas‑Insulated Switchgear for Transmission Substation-800kV
Rated voltage 800kV
Rated normal current 6300A
Series RHG
Description

The RHG-800 GIS is an ultra-high-voltage SF6 gas-insulated metal-enclosed switchgear for 750kV/800kV power transmission systems. Independently developed, it integrates circuit breaker, current transformer, disconnector, earthing switch, main busbar, bushing, and surge arrester in a compact modular design.

The circuit breaker interrupter features a double-break structure with a hydraulic operating mechanism designed to prevent oil leakage and slow-opening at low pressure.

Main Features

  • Double-Break Circuit Breaker: Reliable interruption for 800kV class UHV systems.
  • Hydraulic Operating Mechanism: Internal pipeline design prevents oil leakage; no slow-opening at zero pressure.
  • High Current Capacity: 6300A rated current for bulk power and renewable energy transmission.
  • High Insulation Level: Fully enclosed SF6 insulation for reliable UHV performance.
  • Proven Track Record: Installed at Guanting Substation, 750kV Northwest China transmission project.
  • Compact Modular Construction: Space-saving design for UHV substations.

Technical Parameters

 

No. Item Unit Value
1 Rated voltage (Ur) kV 800
2 Rated frequency (fr) Hz 50
3 Rated normal current (Ir) A 6300
4 Rated short-circuit breaking current (Isc) kA 50
5 Power-frequency withstand voltage (Ud, 1min) — To earth kV 960
6 Power-frequency withstand voltage (Ud, 1min) — Across isolating distance kV 960(+460)
7 Lightning impulse withstand voltage (Up) — To earth kV 2100
8 Lightning impulse withstand voltage (Up) — Across isolating distance kV 2100(+460)
9 Switching impulse withstand voltage (Us) — To earth kV 1550
10 Rated short-time withstand current (Ik) kA 50
11 Rated peak withstand current (Ip) kA 135
12 Rated short-circuit duration (tk) s 3
13 Mechanical life — Circuit breaker / Disconnector operations 5000
14 SF₆ annual leakage rate %/year ≤0.1
15 Circuit breaker operating mechanism — Hydraulic

Environmental Conditions

  • Ambient Temperature: −40°C to +55°C (outdoor)
  • Altitude: ≤ 1000m
  • Relative Humidity: ≤ 95% daily average
  • Installation: Outdoor
  • Seismic Resistance: AG5 class (verify with factory)

Documentation Resource Library HV Gas Insulated Switchgear (GIS)

ZF HV Gas-Insulated Switchgear (GIS)
Restricted
ZF HV Gas-Insulated Switchgear (GIS) ZF HV Gas-Insulated Switchgear (GIS)
Catalogue
English
PDF
Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

Due to the excellent insulation performance, arc extinguishing performance and stability performance of SF6 gas, GIS equipment has the advantages of small footprint, strong arc extinguishing ability and high reliability, but the insulation ability of SF6 gas is greatly affected by the uniformity of the electric field, and it is easy to have insulation abnormalities when there are tips or foreign objects inside the GIS.

GIS equipment adopts a fully enclosed structure, which brings the advantages of internal components without environmental interference, long maintenance cycle, low maintenance workload, low electromagnetic interference, etc., while also having problems such as complex single overhaul work and relatively poor detection methods, and when the closed structure is eroded and damaged by the external environment, it will further bring a series of problems such as water ingress and air leakage.

The insulating property of SF₆ gas relies on its stable molecular structure, which makes electron escape and collision ionization difficult under normal operating voltages, ensuring high insulation resistance. In GIS, insulation is precisely maintained by controlling gas pressure, purity, and electric field distribution to guarantee a uniform and stable electric field between high-voltage conductors and the grounded enclosure.

Equipped with current transformers and various sensors, this GIS integrates overcurrent, short-circuit, ground fault and overvoltage protection functions; it monitors real-time electrical parameters, automatically trips the circuit breaker and triggers protection actions once current or voltage abnormalities are detected to isolate faulty circuits and guarantee safe operation of the power system and equipment.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register