| Brand | ROCKWILL |
| Numero ng Modelo | Compact na HV Shunt Capacitor Bank hanggang 80000kVar |
| Tensyon na Naka-ugali | 66kV |
| Larawan na Pagsasahimpapawid | 50/60Hz |
| Serye | TBB |
Ang mga aparato ng high-voltage shunt capacitor ay pangunahing binubuo ng mga sumusunod na kagamitan: high-voltage shunt capacitors, series reactors, discharge coils, zinc oxide arresters, isolation grounding switches, frames, bus bars, connecting wires, post insulators, cabinets o fences, atbp. Ang switching circuit breaker ng capacitor device at ang kanyang protection device at controller ay maaaring kasama sa supply ayon sa pangangailangan ng mga user.
Ang mga aparato ng high-voltage shunt capacitor ay pangunahing ginagamit sa power frequency three-phase AC power systems upang mapabuti ang system power factor, bawasan ang transformer at line losses, mapabuti ang kalidad ng grid voltage, at mapataas ang paggamit ng kagamitan.
Ang buong disenyo ay may design na nakahiga, compact structure at maliit na floor space.
Ang frame ng capacitor ay may modular design, na madaling ilipat at i-install.
Ito ay angkop para sa outdoor at indoor use.
Mga parametro
Rated voltage |
6,10,35,66,110Kv Etc. |
Rated frequency |
50/60Hz |
Rated capacity |
3600,4800,6000,8000,10000,20000,80000kvar Etc. |
Reactance rate |
1%,5%,12% |
Connection mode: |
single star connection (open triangle AK, phase voltage differential protection AC, bridge differential pressure AQ) double star connection (unbalanced current protection BL) |
Installation place |
outdoor or indoor |
Environmental temperature category |
-40℃~+45℃ |
Altitude |
≤4000 |
Solar radiation intensity |
0.11W/cm2 |
Pollution level |
Ⅳ grade |
Relative humidity |
Para sa indoor reactors, ang average relative humidity ng buwan ay hindi lumalampas sa 90%, at ang daily average ay hindi lumalampas sa 95% |
Earthquake intensity |
Ang basic design erthquake intensity ay 8 degrees; that is, the horizontal acceleration is 0.3g and the vertical acceleration is 0.15g |
The maximum wind speed of outdoor type |
35m/s |
Three-cycle safety factor of sinusoidal resonance |
≥1.67 |
Klasipikasyon
Ayon sa installation type, ito ay maaaring hatiin sa dalawang uri: cabinet type at frame type.
Ayon sa switching mode, ito ay maaaring hatiin sa manual switching at automatic switching.
Ayon sa kondisyon ng paggamit, ito ay maaaring hatiin sa indoor at outdoor types.
Pangunahing tungkulin:
Ginagamit ito pangunahin sa three-phase power systems tulad ng power frequency voltage 10kV~750kV upang ayusin at balansehin ang voltage ng substation network, mapabuti ang power factor, bawasan ang loss, at mapabuti ang kalidad ng power supply.