• PQF Series Active filters
PQF Series Active filters
discuss personally
Model
PQFI-300/0.4
PQFM-150/0.4
PQFS-100/0.4
PQFS-100/0.4
PQFM-100/0.4
PQFS-90/0.4
PQFS-80/0.4
PQFS-40/0.4
PQFS-40/0.4
Basic info
Brand Wone Store
Model NO. PQF Series Active filters
Rated voltage 400V
Rated normal current 300A
Mounting type 一体式
Series PQF Series
Product Detail

Overview

Operational efficiency

● Fewer events of equipment failure due to poor power quality of the network, thereby creating trouble-free and effcient operations
● Improved performance of loads thanks to a cleaner supply network

Cost effciency

● Increased lifetime of the equipment enabling lower plantrunning costs
● Compliance with the strictest regulations (such as individual harmonic limits) thanks to the unique control concept, thereby avoiding penalties and/or refusal by utilities to connect installations to the electrical grid

Energy effciency
Lower energy losses in cables and transformers and hence a higher efficiency of the system but also a reduction of CO2 emissions

Better safety of the installations and better operation

Of sensitive loads as the voltage drop between neutral and earth is reduced

Harmonic filtering effciency

The active filters PQF have high filtering efficiency due to the following features:
● Capability of filtering up to 20 harmonics simultaneously
●  Selection of harmonics up to the 50th harmonic
●  Harmonic attenuation factor better than 97%
●  Desired harmonic levels can be preset for each selectedharmonic

Reactive power compensation
PQF can perform precise stepless reactive power compensation of both inductive and capacitive loads. The target cos φ is programmable from 0.6 (inductive) to 0.6 (capacitive) which makes PQF an alternative to a conventional capacitor bank. Moreover this allows compensation of loads fed by generators without the risk of overcompensation. In addition, capacitiveloads can also be compensated.

Load balancing
This feature is available in both 3 and 4-wire systems between phases and between phase and neutral. It helps to improve voltage unbalance on the phases and reduction of neutral current which increases the safety of the installation and allows sensitive loads to operate.

Application

Active harmonic filters installed in parallel to the power feed cancelled the harmonic currents allowing ‘clean’ ECG recordings. An Australian hospital, located in Melbourne, Victoria, is one
of the country’s leading public hospitals established in 1848. It is a major teaching hospital for tertiary health care with a reputation in clinical research. It has one of the largest.Emergency

Technology parameters

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
Active filter PQF Data sheet
White paper English
Consulting
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!