• 107kWH-232kWH Box integrated Energy Storage System(ESS)
107kWH-232kWH Box integrated Energy Storage System(ESS)
$294000.00
Model
JASS-100-215KF
JASS-50-107KF
JASS-100-232KL
JASS-500-1M
Basic info
Brand RW Energy
Model NO. Box integrated ESS
Cooling mode Liquid cooling
Rated Output Rating 100kw
Energy storage capacity 215kWh
Series Industrial&Commercial energy storage
Product Detail

Peculiarity

  • Modular energy storage converter parallel design concept, improve system stability, easy installation and maintenance, easy expansion.

  • Battery pack is replaceable, can be adapted to a variety of batteries, for different batteries to achieve different charging and discharging strategies; Low operation and maintenance cost.

  • Energy scheduling can be regulated, and users can change the charge and discharge logic according to the power consumption policy of different periods in the region.

  • Power factor can be adjustable, can achieve active power, reactive power independent control, to meet the needs of different loads.

  • Energy balance management controller is used to refine the energy management of the energy storage system to the battery PACK level.

  • Battery PACK level energy balance management controller to avoid capacity loss caused by mismatch.

  • Support the mix of old and new batteries, so that recharge phased deployment.

  • Outdoor modular energy storage converter cabinet design, high power density, easy maintenance.

Technical parameter

image.png

image.png

How does the battery management system in ESS protect against short circuits?

Identify short-circuit situations.

  • Current detection:The BMS identifies short-circuit conditions by continuously monitoring the current changes of the battery pack. When an abnormally high current is detected, a short circuit may have occurred.

  • Voltage monitoring:In the case of a short circuit, the voltage of the affected battery cell or the entire battery pack may suddenly drop. The BMS identifies this abnormal situation through vltage monitoring.

  • Temperature monitoring:A short circuit will cause a sharp rise in local temperature. The BMS detects abnormal temperature rises through temperature sensors to determine whether a short circuit has occurred.

Implement protection measures.

  • Cut off power supply:When a short circuit is detected, the BMS will immediately cut off the connection between the battery pack and the external circuit through relays or switches to prevent the current from continuing to flow and avoid excessive discharge or heating of the battery.

  • Alarm and record:Trigger the alarm system to send a warning signal to the operator and record relevant information such as the time and location of the short circuit occurrence for subsequent investigation and handling.

  • Isolate faulty units:If the short circuit occurs in a certain battery cell rather than the entire battery pack, the BMS can isolate the cell to prevent it from affecting other normal battery cells.



Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!